Plug-in pipe connector complete catalogue
20Pages

{{requestButtons}}

Catalog excerpts

Plug-in pipe connector complete catalogue - 1

The Plug-In Connector. BEULCONNECT. For water and gas.

Open the catalog to page 1
Plug-in pipe connector complete catalogue - 2

MINIMUM EFFORT. MAXIMUM EFFECT.

Open the catalog to page 2
Plug-in pipe connector complete catalogue - 3

The BEULCONNECT plug-in connector is constructed in such a way that it clamps the pipe by a gentle plug-in technology. It is leakproof for a lifetime and enables a trouble-free and stress-free installation. The plug-in connector guarantees special safety: The pipe only has to be plugged-in - a control can be omitted (e.g. whether a pressing nut has been correctly tightened). Dimensions: • for plastic pipes: 0 25 mm to 0 63 mm Nominal pressure: • PE 80 (PN 12,5), PE 100 (PN 16), PE-Xa (PN 12,5) Connector (for water) tested acc. to: • DIN 8076/DVGW GW 335-B4 DN 20 - DN 50 Water • Kiwa...

Open the catalog to page 3
Plug-in pipe connector complete catalogue - 4

Installation Instruction BEULCONNECT - A11 Plug-in connector Step 1 Cut the pipe at a right angle at the previously affixed marking. Step 3 Mark the insertion depth on the pipe. (For the use in gas sector the insert pipe has to be pressed in up to the limit stop) Step 2 Chamfer the pipe up to the inner diameter (e.g. with chamfering tool model 8880, item 124527). Step 4 Insert the pipe up to the marking. The insertion depth of the pipe is made visible by a marking on the fitting body. Note: • For oval pipes we recommend the use of insert pipes in order to guarantee the optimal holding and...

Open the catalog to page 4
Plug-in pipe connector complete catalogue - 5

Installation Instruction BEULCONNECT Repair Program Repair Coupling Step 1 Cut the pipe at a right angle at the previously affixed marking. Step 3 Mark the insertion depth on both pipes. Step 2 Chamfer the pipe up to the inner diameter (e.g. with chamfering tool model 8880, item 124527). Step 4 Insert the pipe on the first side up to the marking. Step 5 Insert the pipe on the second side up to the marking Repair Connector Step 1 Cut the pipe at a right angle at the previously affixed marking. Step 3 Mark the insertion depth on the pipe. Step 2 Chamfer the pipe up to the inner diameter (e.g....

Open the catalog to page 5
Plug-in pipe connector complete catalogue - 6

Plug-In Connector - Repair Program BEULCONNECT - A11 For the safe bridging of pipe damages the BEULCONNECT repair couplings and connectors offer the optimal solution. The repair assortment is designed in a way that due to the material-friendly smart grip technology the pipe is only stressed as the pressure situation requires. Repair Coupling The BEULCO repair couplings are equipped with two equal plastic pipe connections and ensure the ideal bridging of pipe damages. The plug-in technology guarantees a fast and safe installation. bridgeable lengths: from 150 mm to 280 mm (depending on...

Open the catalog to page 6
Plug-in pipe connector complete catalogue - 7

BEULCO Overview Image

Open the catalog to page 7
Plug-in pipe connector complete catalogue - 8

made in Germany Plug-In Connector without Insert Pipe - A11 CONNECTOR, MALE THREAD Model 1101 with plastic pipe connection and male thread Item may differ from the picture.

Open the catalog to page 8
Plug-in pipe connector complete catalogue - 9

CONNECTOR, FEMALE THREAD Model 11110 with plastic pipe connection and female thread Item may differ from the picture.

Open the catalog to page 9
Plug-in pipe connector complete catalogue - 10

made in Germany Plug-In Connector without Insert Pipe - A11 ELBOW 90°, REDUCED MALE THREAD Model 11300 with plastic pipe connection and reduced male thread plastic pipe dimension (mm) ELBOW 90°, INCREASED MALE THREAD Model 11302 with plastic pipe connection and increased male thread

Open the catalog to page 10
Plug-in pipe connector complete catalogue - 11

APPLICATION D • = Drinking water w| • = Water G • = Gas REPAIR COUPLING Model 1106 Item may differ from the picture. We recommend to extend the repair couplings to the maximum length during assem bly and to shorten the pipe accordingly. If this is not possible, benchmarks must be placed in front of and behind the connector. Item may differ from the picture. We recommend to extend the repair couplings to the maximum length during assem bly and to shorten the pipe accordingly. If this is not possible, benchmarks must be placed in front of and behind the connector. plastic pipe dimension...

Open the catalog to page 11
Plug-in pipe connector complete catalogue - 12

made in Germany Plug-In Connector without Insert Pipe - A11 GATE VALVEModel 11700 Item may differ from the picture.

Open the catalog to page 12
Plug-in pipe connector complete catalogue - 13

D • = Drinking water w| • = Water G • = Gas BEULCO CONNECTOR, MALE THREAD Model G1101 with plastic pipe connection and male thread with insert pipe Item may differ from the picture. Installation instructions see page 4/5

Open the catalog to page 13
Plug-in pipe connector complete catalogue - 14

| made ■ in | Germany Plug-In Connector without Insert Pipe - A11 COUPLING Model G1105 with 2 equal plastic pipe connections with insert pipe Item may differ from the picture.

Open the catalog to page 14
Plug-in pipe connector complete catalogue - 15

APPLICATION D • = Drinking water w| • = Water G • = Gas ELBOW COUPLING Model G11301 with 2 equal plastic pipe connections with insert pipe Installation instructions see page 4/5

Open the catalog to page 15
Plug-in pipe connector complete catalogue - 16

| made ■ in | Germany Plug-In Connector without Insert Pipe - A11 ELBOW ADAPTER Model G11600 for tapping valve, freely turnable with plug-in connection with insert pipe for plastic pipe, union nut Tr 63 x 5 Item may differ from the picture.

Open the catalog to page 16
Plug-in pipe connector complete catalogue - 17

APPLICATION D • = Drinking water w| • = Water G • = Gas INSERT PIPE Model 8900 For oval pipes we recommend the use of insert pipes in order to guarantee the optimal holding and sealing functions. SEALING BAND "LOCTITE" Model 9998 Not hardening thread sealing to seal conical/ cylindrical threads up to 6". Reversing the thread is possible. Temperature stability up to 130° C. DVGW registration no. DV-5142AU0166. Recommendation of KTW is available.

Open the catalog to page 17
Plug-in pipe connector complete catalogue - 20

info@beulco.de www.beulco.de BEULCO® GmbH & Co. KG Kolner Str. 92 Postbox 1 20 Phone +49 2722 695-0

Open the catalog to page 20