General Description
The Bettis DeltaMatic™ linebreak detection system is engineered to automatically monitor gas pipelines and send an instrument pressure signal if a predetermined rate of pressure drop is exceeded. This system is crucial for detecting pipeline breaks and signaling valve operators, ensuring safety and environmental protection in various locations such as populated areas and river crossings.
Features and Benefits- Operates on pipeline pressure without electrical power.
- Accommodates normal pipeline pressure fluctuations without triggering shutdowns.
- Compact design, fully assembled unit.
- Can be retrofitted into existing systems with minimal field setup.
- Installable remotely or directly on valve operators.
- Utilizes a labyrinth type flow restriction for larger passage sizes.
- Standard rate of drop ranges from 5 to 120 psi/minute, adjustable in the field.
- Operates in extreme cold environments down to -50°F (-46°C).
Operation
The system functions with the line valve open, closing it when power gas is present. Line pressure is applied to a differential pressure pilot and rate tank through a check valve. The differential pressure pilot compares line pressure with reference pressure in the rate tank, creating a differential pressure across a restrictor. This pressure is directly related to the rate of drop of line pressure, and the pilot is calibrated to vent a signal when the rate of drop exceeds a set threshold.
Components- Operator
- Line Valve
- Gas/Hydraulic Tank
- 3-Way Valves (Manual and Manual/Pilot)
- Selector Valve
- Speed Control Valve
- Check Valve
- Handpump
- Filter
- Pressure Regulator
- Relief Valve
- End of Stroke Valve
Calibration and Adjustment
The system's rate of drop setting can be adjusted by changing the DeltaMatic pilot's differential pressure setting. This may involve selecting a different spring, which can be changed and recalibrated in the field. The system can also be converted to a different nominal range by fitting a different restrictor.
Available Options- Backup low pressure detection
- Adjustable time delay control system
- Sour gas pipeline application
- Weatherproof enclosure
- Prefilter on pipeline connection
- Alarm to control room pressure switch
- Higher rate of drop ranges
- Manual reset, lockout, or override
Operating Environment and Specifications- Line pressure range and temperature limits
- Humidity, rain, and snowfall considerations
- Service media and mounting options
- Control specifications including rate of pressure drop range and setpoint
- Pneumatic supply pressure and output signal options