Group: Yaskawa
Catalog excerpts
• Elevators ^nd Parking Machines * • With Bestact
Open the catalog to page 1Bestact’s high reliability provides stability for high-speed elevator operation. Since Bestact, a hermetically sealed glass contact power reed switch; was placed in service over 30 years ago; over 18 million have been used worldwide in applications such as transit train control, elevators and electric power facilities. Along with the construction of more high-rise buildings, the elevators that service them require more stable, reliable operation with ease of maintenance. Automatic monitoring of elevators now occur in hotels, apartment houses, department stores and railway yards around the...
Open the catalog to page 2Conventional reed switches are often used as an input device in conjunction with interface relay because contact reliability will go down in an adverse environment or when neglected for a long time. Bestact is a hermetically sealed contact, which exhibits no environmental or deterioration over time. This leads to long-term stable contact reliability. Therefore, no interface relay is needed and direct input is achievable while reducing control circuitry costs. Conventional reed switch Interface relay Logic circuit Logic circuit Conventional circuit Circuit incorporating Bestact Comparison of...
Open the catalog to page 3detection. When the car moves in either and up or down direction, the stop target Vane enhances the magnetism of magnetic proximity switch on the elevator car turning it on (or off) and sending a signal to the elevator control system. DOWN SIDE FACE Direction detecting switch; operates at the beginning along with the movement of the car and detects which the car is moving up or down. Door opening command switch; operates just before the movement of the car and commands to open the door. Landing floor detecting switch; movement of this switch detects the coincidence of the elevator floor...
Open the catalog to page 4Features of Bestact Highly Reliable Contact Employing New Materials and Innovative Designs such as Wiping and Hammering Action, Bifurcated Contact and Back-Stop Mechanism. 1.Sealed with an inert gas, ensuring freedom from aging and influences exerted by an adverse environment. 2.The twin contact and wiping effect assures outstanding contact reliability. 3.Hammering action and back-stop mechanism permits a larger make and break capacity and longer service life. ■CONSTRUCTION AND OPERATING MECHANISM MOVABLE CONTACT MAGNETIC MEMBERS BACKSTOP MECHANISM RETURN SPRING HINGE POINT BENT END...
Open the catalog to page 5Usage in Elevators and Parking Machines Over 2.33 million have been used from 1981 to April, 2011. Application Product Type Approx. Accumulated Main Customer Vane type magnetic proximity switches TOSHIBA ELEVATOR Nippon Otis Elevator FUJITEC Schindler Elevator NIPPON ELEVATOR YOKOHAMA ELEVATOR Door-zone detection Landing-zone Daiko MORIYA Kumalift Huasheng Fujitec Elevator LG-OTIS Elevator Sigma Elevator Fujitec America Elevator Detection Gap 25mm(CCC Certification) Contact unit and driving magnet for OEM Hitachi FUJITEC Memory type magnetic proximity switch(15mm gap) Huasheng Fujitec...
Open the catalog to page 6Bestact products are manufactured in the most advanced facilities, utilizing the expertise we have gained from years of ongoing research and development as well as empirical field data under a stringent quality control system. As example of this would be our production equipment, which automatically adjusts the spring load to the optimum value, thereby maximizing contact life and reliability. Quality management on the Bestact production line ^Order processing, production management Parts procurement^ ^Mechanical processing^ ^ ^Surface treatment^ Receiving inspection Parts cleaning and...
Open the catalog to page 7•Before initial operation, read through the product's instruction manual and other attached documents) thoroughly and use the product properly. •Although the product is produced under strict quality control, you must apply a safety device if the product is applied to a machine for which malfunction can risk human life or may seriously damage facility. •Wiring must be done by an expert of electrical wiring. •Do not modify the product under any circumstances. ■Warranty Period The warranty period for a product that was purchased is one year from the time of delivery to the location specified...