Overview: The Junior LB 9509 is a portable tube luminometer designed for applications involving glow-type bioluminescent and chemiluminescent reagents. Its compact size, lightweight, and battery operation make it versatile for use in laboratories, on-site, or outdoors. It is applicable in fields such as biomedical research, clinical diagnostics, hygiene monitoring, biotechnology process control, and environmental monitoring.
Sensitivity: The device features a state-of-the-art single photon counting photomultiplier with low noise. A high sensitivity model is available, reducing the detection limit to less than 50 amol ATP.
Dynamic Range: The luminometer offers a wide dynamic range, allowing measurement of both low and high signals without changing settings, thanks to BERTHOLD TECHNOLOGIES' single photon counting electronics.
Independence: The Junior operates independently from a mains supply for extended periods due to rechargeable batteries. It can also be connected to a mains supply for automatic recharging.
Versatility: The measuring chamber accommodates various sample tubes and sizes, including traditional lumi vials, microcentrifuge tubes, and capped vials.
Ease of Use: Operated via a membrane keypad, the software displays protocol, sample location, and RLU value. LEDs indicate if a sample is above, below, or within set limits.
Data Management: Stores up to 2,000 measurement results, searchable by time and location. Results can be downloaded to a PC using WinTerm software, which organizes data into Excel spreadsheets.
Portability: Weighing only 2 kg, the Junior is easily transportable, with a metal case available for outdoor use.
Reliability: The selection of detectors ensures minimal day-to-day variation, providing reliable measurements.
Applications: The Junior is suitable for reporter gene assays, ATP determination, hygiene monitoring, water sample toxicity testing, enzyme activity assays, DNA probe assays, Mycoplasma detection, and luminescent immunoassays.
Technical Specifications: The device operates within a spectral range of 380-630 nm, with a dynamic range of 6 orders of magnitude. It supports various tube formats and features an illuminated graphic display. The power supply is 110-230 V, and it operates within a temperature range of 15-35°C.
Order Information: The Junior LB 9509 is available in high sensitivity and standard models, with various accessories such as lumivials, adapters, rechargeable batteries, and a transport case.
See more

Catalog excerpts

Junior LB 9509-1

Junior LB 9509 The portable tube luminometer

 Open the catalog to page 1
Junior LB 9509-2

Junior LB 9509 The portable tube luminometer The Junior is a small portable tube luminometer designed for all common applications using glowtype bioluminescent and chemiluminescent reagents. Excellent performance, its small size and low weight paired with battery operation make the Junior a highly versatile instrument which can be used in any location – the laboratory, on site or outdoors. The Junior is used in a number of diverse fields of application including biomedical research, clinical diagnostics, hygiene monitoring, process control in biotechnology and environmental monitoring, e.g. water...

 Open the catalog to page 2
Junior LB 9509-3

The unique design of the measuring chamber allows the use of a variety of different sample tubes and sizes. Besides the traditional lumi vials, microcentrifuge tubes (Eppendorf cups) and capped 4 mL vials can be used. The Junior can be operated independently from a mains supply for many hours as it is equipped with rechargable batteries. In the lab the instrument can be connceted to a mains supply thereby automatically recharging the batteries.

 Open the catalog to page 3
Junior LB 9509-4

The lean and dedicated software is operated through a membrane keypad. The well arranged graphical display shows selected protocol, sample With a weight of only 2 Kg and its small size the Junior can be carried and taken to the sampling location for measurements on site. location and number and the RLU value of the measurement. In addition a set consisting of a red, a yellow and a green LED unmistakably indicates whether a signal and thus a sample is above an upper limit (red), below a lower limit (green) or in between (yellow). A metal transport case providing space for the Junior and accessories...

 Open the catalog to page 4
Junior LB 9509-5

Applications Reporter Gene Assays In basic research of gene regulation as well as in drug discovery and recently even in clinical diagnostics luciferases, ß-glucuronidases, ß-galactosidases and secreted alkaline phosphatases have become standard tools offering high sensitivity and wide dynamic range. Dual reporter type assays, e.g. DualGlo™ reporter gene assay, are popular as they provide an internal control for transfection efficiency or general expression level and cell viability. Chemistries with a stable light emission can be measured with the Junior by adding the reagents manually. Toxicity...

 Open the catalog to page 5
Junior LB 9509-6

Detection unit photomulitiplier in single photon counting mode spectral range 380 - 630 nm Sensitivity standard model: <3 fmol ATP 0.4 amol firefly luciferase, high sensitivity model: <50 amol ATP <30 zmol firefly luciferase Dynamic range 6 orders of magnitude Tube formats lumi vials 12 x 47 mm (09777) lumi vials 12 x 55 mm (26152) lumi vials 12 x 75 mm (09778) vials 15 x 42 mm (32737) Eppendorf tubes 2 mL Eppendorf tubes 1.5 mL capped vials 4 mL 14 x 54 mm Display illuminated graphic display, 128 x 64 pixel 3 LEDs (green, yellow, red) connected to software-set threshold levels Software built-in...

 Open the catalog to page 6