Coded magnetic switches Safely monitor doors, flaps and hoods
Open the catalog to page 1Coded magnetic switches for various applications Safety switches are usually used for the safety-related monitoring of doors, hoods and flaps. But due to other requirements, such as environmental conditions or the complexity of the application, it may be necessary to switch from a mechanical safety switch to another technology, such as coded magnetic switches. Our magnetic switches are sensors with a two-channel output. In order to meet the requirements of EN 14119 and EN 60947-5-3 for a type 4 interlocking device, this output must be connected to a suitable evaluation device. To make it more...
Open the catalog to page 2MAK 42 ... Sensors Article number Contact configuration safety contacts Signalling contacts Technical data No. (see page 10) 3 meter cable, right 6 meter cable, right 9 meter cable, right 3 meter cable, right 3 meter cable, right 6 meter cable, right Other cable lengths are available on request *Only valid in connection with the MÜZ evaluation unit Article number Dimension drawings 1) MAK 42 sensor, cable on the right Technische Daten Magnetschalter Baureihe MA-42 Typbezeichnung MAK-4236-BCD-M8 2) MAK 42 sensor, 4 pin M8 connector on the right active side aktive Seite Anfahrrichtung / Schaltabstand...
Open the catalog to page 3MAK 52 ... Sensors Article number Contact configuration safety contacts Signalling contacts Technical data No. (see page 10) 3 meter cable, left 6 meter cable, left 9 meter cable, left 1,5 meter cable, on the side 1,5 meter cable, right 3 meter cable, left 3 meter cable, left Other cable lengths are available on request *Only valid in connection with the MÜZ evaluation unit Article number 6) MAK 52 sensor, cable on the side Dimension drawings 4) MAK 52 sensor, cable on the right Technische Daten Technische Daten 7) MAK 52 sensor, 4 pin M8 connector on the left Verschlussstopfen Closing plug Magnetschalter...
Open the catalog to page 4MAK 53 ... Sensors Article number Contact configuration safety contacts Signalling contacts Technical data No. (see page 10) 3 meter cable, on the back 6 meter cable, on the back 9 meter cable, on the back 3 meter cable, on the back Other cable lengths are available on request *Only valid in connection with the MÜZ evaluation unit Article number Technische Daten Dimension drawings Typbezeichnung MAK-5336-BCD-3 9) MAK 53 sensor, cable on the back Technische Daten Magnetschalter Anfahrrichtung / Schaltabstand Baureihe MA-53 Typbezeichnung MAK-5336-BCD-M12 S 10) MAK 53 sensor, 4 pin M12 connector...
Open the catalog to page 5Technical details Technical data – magnetic switches maximum switching voltage maximum switching current maximum Temperature switching power with movable cable with fixed cable Protection class Low coding level according to DIN EN 14119 Explanation of the switching distances of magnetic switches Sao To achieve a PL or SIL value with the safety sensors from the MAK family, it is necessary to connect them to a safety evaluation system. The evaluation system (BERNSTEIN designation: MÜZ) monitors the correct switching of the two magnetic switch channels within a defined time window in which both...
Open the catalog to page 6Contact International Headquarters BERNSTEIN AG Hans-Bernstein-Str. 1 D–32457 Porta Westfalica Phone + 49 571 793-0 Fax + 49 571 793-555 [email protected] www.bernstein.eu Denmark BERNSTEIN A/S Phone + 45 7020 0522 Fax + 45 7020 0177 [email protected] We keep safe your visions. Austria BERNSTEIN GmbH Phone +43 2256 62070-0 Fax +43 2256 62618 [email protected] Italy BERNSTEIN S.r.l. Phone +39 035 4549037 Fax +39 035 4549647 [email protected] United Kingdom BERNSTEIN Ltd Phone +44 1922 744999 Fax +44 1922 457555 [email protected] Hungary BERNSTEIN Kft. Phone +36 1 4342295 Fax +36...
Open the catalog to page 720 Pages
20 Pages
12 Pages
28 Pages
60 Pages
132 Pages
36 Pages
256 Pages
24 Pages