Mod. F
1 / 14Pages

Catalog excerpts

Mod. F - 1

                     

Open the catalog to page 1
Mod. F - 2

Bladder Tank Fire Protection Mod. F Vertical bladder tank with foam outside the bladder, 2014/68 UE PED certificate DES/G/7 DATA ts reserved No part of this drawing may he reproduced or transmitted in any form or dy any means, without the prior consent in writing of F. A. S. ite disegno e di proprieto F.A.S. E’ VIETATO riprodurla e falsificorlo. FIRE FIGHTING SYSTEMS In order to improve their efficiency, FAS may modify characteristics and dimensions of Us own products without prior notice.

Open the catalog to page 2
Mod. F - 3

                     

Open the catalog to page 3
Mod. F - 4

Bladder Tank Fire Protection Mod. FI Vertical bladder tank with foam inside the bladder, 2014/68 UE PED certificate N'4 FORI 022 N'4 HOLES 022 MESSA A TERRA' GROUND/NG DATI PI PRQGETTO DES/GN DATA NORME PI CALCOLO: DIRETTIVA "PEP” ASME VIII Dlv.1 CAL CVLA 77QN RULES: D/PEC77VE “FED a ASMS WL Dtv, / PRESSIONE PI PRQGETTO: 12 barq DES/GN PRESSURE: 12 barg PRESSIONE PI ESERCIZIO: 12 barq Max WORX/NG PRESSURE; 12 barg Max_ PRESSIONE PI PROVA: 16 barq 7EST PRESSURE: f 8 barg TEMPERATURA PI PRQGETTO: —29’C +80'C DES/GN TEMPERATURE: -29V +80V EFFICIENZA GIUNTI: F0NDI = 1 FA5CIAME=0.65 JO/NT...

Open the catalog to page 4
Mod. F - 5

                     

Open the catalog to page 5
Mod. F - 6

Bladder Tank Fire Protection Mod. Fx2 Vertical double bladder tank with foam outside the bladder, 2014/68 UE PED certificate GROUNDING A/i rights reserved. No part of this drawing may he reproduced or transmitted fa any form or by any means, without the prior consent fa writing of F.A.SL II presentB disegno 6 dl propriety F.A.S. E’ VIETATO rlprodurlo e folslficorlo. FIRE FIGHTING SYSTEMS In order to improve their efficiency, FAS may modify characteristics and dimensions of Us own products without prior notice.

Open the catalog to page 6
Mod. F - 7

                     

Open the catalog to page 7
Mod. F - 8

Bladder Tank Fire Protection Mod. Flx2 Vertical double bladder tank with foam inside the bladder, 2014/68 UE PED certificate DATI DI PROGETTO Aft rights reserved. No part of this drawing may he reproduced or transmitted in any form or hy any means, without the pn'or consent in writing of F.A. S. II presente disegno ft di propriety F.A.S. E" VIETATO riprodurlo e folsificorlo. www.fasspa.net FIRE FIGHTING SYSTEMS In order to improve their efficiency, FAS may modify characteristics and dimensions of Us own products without prior notice.

Open the catalog to page 8
Mod. F - 9

                     

Open the catalog to page 9
Mod. F - 10

Bladder Tank Fire Protection Mod. H Horizontal bladder tank with foam outside the bladder, 2014/68 UE PED certificate E_ DATI DI PROGETTO A/i rights reserved No part of this drawing may be reproduced or transmitted in any /arm or by any means without the prior consent in writihg of F.A.. II presente disegno & di propriety F.A.S. E’ V1ETAT0 riprodurlo e falsificarlo. FIRE FIGHTING SYSTEMS In order to improve their efficiency, FAS may modify characteristics and dimensions of Us own products without prior notice.

Open the catalog to page 10
Mod. F - 11

                     

Open the catalog to page 11
Mod. F - 12

Bladder Tank Fire Protection Mod. HI Horizontal bladder tank with foam inside the bladder, 2014/68 UE PED certificate DATI Dl PROGETTD ATI rights reserved Wo port of this drowihg may be reproduced or transmitted in any form or by any means, without the prior consent in writ/bg of F. A. S. II presents dlsBgno & dl propriBtfl F.A.S. E’ VIETATO rlprodurlo a folslficorlo. FIRE FIGHTING SYSTEMS In order to improve their efficiency, FAS may modify characteristics and dimensions of Us own products without prior notice.

Open the catalog to page 12
Mod. F - 13

              

Open the catalog to page 13

All BERMAD CS Ltd catalogs and technical brochures

  1. Model IR-13Q

    2 Pages

  2. Model MN-C30

    4 Pages

  3. Model MN-C50

    4 Pages

  4. Model MN-C70

    4 Pages

  5. MONITOR MB3

    13 Pages

  6. Model 42T

    4 Pages

  7. Model 43T

    4 Pages

  8. Model A72

    2 Pages

  9. WW-923-MV

    1 Pages

  10. WW-9PM-MV

    4 Pages

  11. WW Intro ES-EN

    36 Pages

  12. 823

    2 Pages

  13. 700 ES

    5 Pages

  14. Sewage

    2 Pages

  15. Air Valves

    4 Pages

  16. 700-2S

    4 Pages

  17. 700-C2

    4 Pages

  18. IR 43Q

    1 Pages

  19. BIC 550

    2 Pages

  20. IR 420-48

    2 Pages

  21. IR 423

    2 Pages

  22. IR 420-55-X

    2 Pages

  23. IR 420-55

    2 Pages

  24. IR 420-XZ

    2 Pages

  25. IR 420

    2 Pages

  26. WW 735-55-M

    6 Pages

  27. WW 735-M

    6 Pages

  28. WW 743

    4 Pages

  29. WW 740Q

    6 Pages

  30. WW 750-65

    4 Pages

  31. WW 750-66-B

    4 Pages

  32. IR 453-66

    2 Pages

  33. IR 450-65-Z

    1 Pages

  34. IR 450-60-R

    2 Pages

  35. IR 450-80-XZ

    2 Pages

  36. IR 457-66-U

    2 Pages

  37. Y" Strainer

    1 Pages

  38. WW-720

    4 Pages

  39. Model PC3Q

    1 Pages

  40. 750-80-X

    6 Pages

  41. 750-66-B IOM

    2 Pages

  42. 74Q IOM

    2 Pages