Level Control Valve with Bi-Level Vertical Float (Sizes 1½-24"; DN40-600) The Model 750-66-B Level Control Valve with Bi-Level Vertical Float is a hydraulically operated, diaphragm actuated, double chambered control valve. The valve is hydraulically powered to fully open at pre-set reservoir low level, and to shut off at pre-set high level regardless of valve differential pressure. Ensure enough space around the valve assembly for future maintenance and adjustments. Prior to valve installation, flush the pipeline to insure flow of clean fluid through the valve. For future maintenance, install Isolation gate valves upstream and downstream from Bermad control valve. Install the valve in the pipeline with the valve flow direction arrow in the actual flow direction. Use the lifting ring provided on the main valve cover for installing the valve. For best performance, it is recommended to install the valve horizontally and upright. For different valve positions – consult Bermad. Install the float pilot assembly either at an external balancing tank or at an internal stilling tank (refer to the enclosed "Float #66" catalog page). Pull three parallel ½” or ⅜" control tubes, from the valve to the float. Mark each of the tubes at both sides for identification. It is highly recommended to install a strainer Bermad model 70F upstream from the pressure reducing valve, to prevent debris from damaging valve operation. Determine the desired rod length according to level differential between the float assembly and reservoir lowest level. Assemble the extension rods to the upper rod and to one another. Apply glue (“Loctite 200" or equivalent) and screw tight. Be careful not to damage the rod. Install the upper & lower stoppers on the rod without the float ball. Use 3/16” Ellen-Key to lock the stoppers on the rod. Screw the upper rod to its place at the bottom of the lever system & tighten the lock nut by ½” spanner. Balance the float assembly by moving the weight against the rod and stoppers (without the float ball). After reaching equilibrium, tighten the balancing-weight screw and its lock-nut by 7/16" spanner. Remove the lower stopper to enable threading-in the float ball. Reassemble the lower stopper & lock it in its place. Note: You may have to pull out the whole rod, in order to reach the lower stopper. If so, release the rod lock-nut, unscrew the installed rod (with its extensions & the stoppers) and pull it up from the stilling tank. After threading-in the float ball and locking the lower stopper back in its place, reassemble the installed rod. Connect the control tubes ends, using ⅜” copper or reinforced plastic tube, to the valve and to the float according to control drawing below. 15.1. Tube from valve control filter [4] or (for 10” & larger) [4.1] to float port [P]. 15.2. Tube from float port [C1] to valve cover or (for 10” & larger) to accelerator [54B]. 15.3. Tube from float port [C2] to valve lower chamber or (for 10” & larger) to accelerator [54B.1]. Confirm that cock valves [1] and [1.1] are open (handle parallel to cock-valve body). Confirm that the supply pressure is typical. Adjust the water levels by setting the stoppers: 3.1. Hold the lever system at its upper position & set the upper stopper to 100 mm below desired upper level (but not higher than 150 mm below over-flow level). 3.2. Hold the lever system at its lower position & set the lower-stopper to 100 mm above desired lower level. Open upstream and downstream isolating valves. Allow the 750-66-B to open (ensuring the lever system is at its lower position) and fill-up the reservoir. Vent air from the valve control loop: During filling the reservoir move the lever-system manually to its upper position, forcing the valve to close, then to its lower position, forcing the valve to open. At each position, vent air from the valve control loop by loosening tube fitting at the highest point (pilot float ports [P], [C1] & [C2]), allowing the air to bleed. For 10” valves & larger, air venting is required also from the port [2] of both 3W hydraulic Relay valves [54] & [54.1]. Retighten the fittings eyebolts. Calibrating shutting upper-level: Ensure that the 750-66-B closes as the water level reaches the upper set-level. If the 750-66-B has not closed, move the lever-system manually to its upper position, forcing the valve to close. Change the upper stopper location down, to lower level setting or up to raise it, until the valve closes automatically at the desired upper-level. Calibrating opening lower-level: Allow the water level to drop by consuming from the reservoir or by draining it. Ensure the 750-66-B remains closed until water level
Open the catalog to page 1reaches the desired lower-level, switches at that point and opens fully. Change the lower stopper location down, to lower level setting or up to raise it, until the valve opens automatically at the desired lower-level Note: For switching valve tendency from closing to opening and vice versa, change manually the lever system position up to close and down to open. The 3W hydraulic relay valves [54] & [54.1] quicken valve response. Control Drawing Valve fails to Open: Check for sufficient inlet pressure, confirm float setting & check cock valves status. Valve fails to Close: Confirm float...
Open the catalog to page 2All BERMAD CS Ltd catalogs and technical brochures
-
Model IR-13Q
2 Pages
-
Model IR-22T-3W-X
2 Pages
-
Model IR-11T-N1-2W
2 Pages
-
Model MN-C30
4 Pages
-
Model MN-C50
4 Pages
-
Model MN-C70
4 Pages
-
MONITOR MB3
13 Pages
-
Mod. F
14 Pages
-
Burkert 6281 Series
1 Pages
-
Model 42T
4 Pages
-
Model 43T
4 Pages
-
Model IR-130-59-3W-X
2 Pages
-
Model A72
2 Pages
-
Air Valves Family
2 Pages
-
WW-923-MV
1 Pages
-
WW-9PM-MV
4 Pages
-
Engineering 900
10 Pages
-
WW Municipal 720-55
4 Pages
-
WW Intro ES-EN
36 Pages
-
WW Municipal 723
4 Pages
-
WW Municipal 7PM
4 Pages
-
WW Municipal 820
4 Pages
-
823
2 Pages
-
WW Municipal 720
4 Pages
-
700 ES
5 Pages
-
Sewage
2 Pages
-
Air Valves
4 Pages
-
Air Valve C50
4 Pages
-
700-2S
4 Pages
-
Spare Parts - Waterworks
60 Pages
-
700-C2
4 Pages
-
Feature code – TC
2 Pages
-
DMA Reduced Pressure
1 Pages
-
IR 43Q
1 Pages
-
BIC 550
2 Pages
-
IR 420-48
2 Pages
-
IR 423
2 Pages
-
IR 420-55-X
2 Pages
-
IR 420-55
2 Pages
-
IR 420-XZ
2 Pages
-
IR 420
2 Pages
-
WW 735-55-M
6 Pages
-
WW 735-M
6 Pages
-
WW 743
4 Pages
-
WW 740Q
6 Pages
-
WW 750-65
4 Pages
-
WW 750-66-B
4 Pages
-
IR 453-66
2 Pages
-
IR 450-65-Z
1 Pages
-
IR 450-60-R
2 Pages
-
IR 450-80-XZ
2 Pages
-
IR Engineering 400
12 Pages
-
IR 457-66-U
2 Pages
-
Y" Strainer
1 Pages
-
WW-720
4 Pages
-
Model PC3Q
1 Pages
-
750-80-X
6 Pages
-
3-Way Solenoid
1 Pages
-
3-Way Solenoid
2 Pages
-
2-Way Ball Valve Data Sheet
1 Pages
-
200 Series Engineering
8 Pages
-
172-bDZ Data Sheet
2 Pages
-
170-55-bD Data Sheet
2 Pages
-
100 Series Engineering
9 Pages
-
Air Valves Brochure - IR
4 Pages
-
74Q IOM
2 Pages