Series F Shaft Mounted Helical Technical Up to - 110 kW / 16,500 Nm Geared Motors CF-2.01GB 1
Open the catalog to page 1Total compliance with the ATEX Directive safeguarding the use of industrial equipment in potentially explosive atmospheres is assured for users of our geared products. Certification is available for standard gearboxes and geared motors with badging displaying the CE Mark and the Ex mark, name and location of the manufacturer, designation of series or type, serial number, year of manufacture, Ex symbol and equipment group/category. ATEX directive 94/9/EC (also known as ATEX 95 or ATEX 100A) and the CE Marking Directive are enforced in all EC member states. Compliance is compulsory for...
Open the catalog to page 2SERIES F CONTENTS PAGE General Description _________________________________________________________________ Unit Designations Explanation and use of Ratings and Service Factors _______________________________________ Selection Procedure For Motorised Units ________________________________________________ Output Options ________________________________________________________________________ Mounting Positions Motor Performance Data __________________________________________________________ Motor Details ___________________________________________________________________ Exact Ratios...
Open the catalog to page 4Series F shaft mounted geared motors offer ratios from 5 to 100/1 in double reduction, from 100 to 360 in triple and up to 5600/1 in combined reductions. Motors are available up to 110 kW giving a maximum The series F geared motor is primarily designed as a shaft mounted unit incorporating an integral torque reaction bracket. The units are also available with rubber torque bushes, output flanges, output shafts and KIBO sleeves to allow for trouble free All variants can be fitted with IEC motors of your preference or with our standard own brand motor. Input shaft assemblies are available up...
Open the catalog to page 5Standard Unit with Torque Bush | T | STD Unit without Torque Bush [w] STD Unit with Output Flange |~F~| Motorised with IE2 standard motor Motorised with EPACT standard motor Motorised with IEC high efficiency motor (IE3) Motorised with NEMAhigh efficiency motor (PREMIUM) Unit to allow fitting of IEC motor (customer own motor) Unit to allow fitting of NEMA motor (customer own motor) Reducer unit Reducer unit with fan kit Reducer unit with backstop CCW rotation Reducer unit with backstop CW rotation Reducer unit with fan and backstop CW rotation Reducer unit with fan and backstop CCW rotation...
Open the catalog to page 6Gear unit selection is made by comparing actual loads with catalogue ratings. Catalogue ratings are based on a standard set of loading conditions, whereas actual load conditions vary according to type of application. Service Factors are therefore used to calculate an equivalent load to compare with catalogue ratings. i.e. Equivalent Load = Actual Load x Service Factor Mechanical ratings measure capacity in terms of life and/or strength, assuming 10 hr/day continuous running under uniform load conditions. Catalogue ratings allow 100% overload at starting, braking or momentarily during...
Open the catalog to page 7pure liquids liquids-variable density bottling machinery brew kettles-continuous cookers-continuous duty mash tubs-continuous scale hopper-frequent brick press briquette machine clay working machinery single cylinder live roll main hoists bridge travel trolley travel cable reels cutter head drives manoeuvring winches screen drive utility winches main hoist auxiliary hoist boom, luffing rotating, swing or slew tracking, drive wheels bucket-uniform load bucket-heavy load centrifugal discharge gravity discharge cooling towers induced draft forced draft induced draft large, industrial light,...
Open the catalog to page 8APPLICATION DETAILS Absorbed power of driven machine = 0.7 kW Output speed of gearbox or Input speed of machine = Application = Uniformly loaded belt conveyor Duration of service (hours per day) = 24hrs 2 DETERMINE REQUIRED OUTPUT TORQUE output torque Gearbox output speed 1 DETERMINE MECHANICAL SERVICE FACTOR (Fm) Refer to Load Classification by Application, table 3, page 4 Application = Uniformly loaded belt conveyor Uniform load Refer to mechanical service factor (Fm), table 1, page 3 Duration of service (hours per day) = 24hrs Selected unit's output torque (M2) = 106 Nm, therefore unit...
Open the catalog to page 95 CHECK SERVICE FACTOR Service factor (Fm) of selected unit must be equal or more than required service factor. Required service factor of gearbox = 1.25 NOTE: If any of the following conditions occur then consult Application Engineering Mass acceleration factor > 10 Ambient temperature is above 40°C
Open the catalog to page 10Standard / Inch Hollow Shaft
Open the catalog to page 11Tapped Hole Standard Single Extension | C | Inch Single Extension | N | * - Inch Shaft has an open ended keyway, therefore no "L11" dimensions are required
Open the catalog to page 12SERIES F MOTOR ADAPTERS DOUBLE REDUCTION UNITS IEC Flanges B14 Column 12 entry for units type G (Column 10) MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION NUMBER F0322 F0422 Motor codes marked with * are not suitable for use with Kibo Bushing Limited Availability / Non Preferred IEC Flanges B5 Column 12 entry for units type G (Column 10) RATIO COVERAGE MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION NUMBER F0322 F0422 NEMA Flanges C face Column 12 entry for units type G (Column 10) RATIO COVERAGE MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION...
Open the catalog to page 13SERIES F MOTOR ADAPTERS TRIPLE REDUCTION UNITS IEC Flanges B14 Column 12 entry for units type G (Column 10) MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION NUMBER Motor codes marked with * are not suitable for use with Kibo Bushing Limited Availability / Non Preferred IEC Flanges B5 Column 12 entry for units type G (Column 10) RATIO COVERAGE MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION NUMBER MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION NUMBER F0332 F0432 NEMA Flanges C face Column 12 entry for units type A (Column 10)
Open the catalog to page 14SERIES F MOTOR ADAPTERS QUADRUPLE REDUCTION UNITS IEC Flanges B14 Column 12 entry for units type G (Column 10) MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION NUMBER IEC Flanges B5 Column 12 entry for units type G (Column 10) MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION NUMBER NEMA Flanges C face Column 12 entry for units type A (Column 10) MOTOR / FRAME FLANGE UNIT SIZE, NUMBER OF REDUCTIONS, REVISION NUMBER Limited Availability / Non Preferred
Open the catalog to page 15All BENZLERS catalogs and technical brochures
-
Series X Flexible Couplings
36 Pages
-
SERIES M
94 Pages
-
Roloid Gear Pump
17 Pages
-
Series P Planetary
100 Pages
-
Benzlers Screw Jacks
69 Pages
-
Series J Shaft Mounted Gearbox
73 Pages
-
Series P
4 Pages
-
Series E
4 Pages
-
Compact Motor
4 Pages
-
Series J
4 Pages
-
Series G flyer
4 Pages
-
Benzlers Product Brochure
8 Pages
-
BR Series BS
60 Pages
-
BR Cone Ring Couplings
16 Pages
-
BR Series X Couplings
36 Pages
-
BR Series H
123 Pages
-
BR Series G
71 Pages
-
BR Compact Motors
64 Pages
-
BR Series M
120 Pages
-
BR Series C
106 Pages
-
BR Series K
90 Pages
-
Series BD Screw Jacks
58 Pages
-
Elflex Flexible Couplings
8 Pages
-
Elign Gear Couplings
17 Pages
-
Series X
64 Pages
-
Series G
71 Pages
-
Geared Motor Series M
120 Pages
-
Geared Motor Series C
120 Pages
-
Geared Motor Series K
90 Pages
-
Geared Motor Series F
119 Pages