Catalog excerpts
World Class Power Solutions Excellent Technology, Efficiency and Quality Float charge Float charge/boost charge Battery test Mains fault Unit fault High voltage Low battery voltage Battery circuit fault Battery test negative Earth fault plus Earth fault minus Option 1 Option 2 Rectifiers for stationary battery systems Standard thyristor-controlled rectifiers THYROTRONIC Line
Open the catalog to page 1BENNING World Class Power Solutions THYROTRONIC rectifier range for stationary back up power supply General The protection of electrical load against power failure is often carried out by battery backed up DC power supplies, providing electrical energy to important loads during mains supply, as well as during mains failure. Battery backed up DC power supplies have, over several decades proved extremely reliable and very economical power supplies. The reliability of a battery backed up DC power supply is defined by the quality of the battery used, as well as the reliable operation of the...
Open the catalog to page 2BENNING World Class Power Solutions Type table THYROTRONIC_ rectifier range for multi-purpose use Nom. No. of No. of Output Mains Current Cabinet Weight voltage cells cells Current Type voltage consump. type Subject to technical change without notice, other types on request
Open the catalog to page 3BENNING World Class Power Solutions THYROTRONIC rectifier range for multi-purpose use Operation Lead-acid and nickel-cadmium batteries achieve optimum service life when remaining on float, in a charged condition. The charger floats the battery in a charged state and also supplies the load with power. In the event of mains power failure the battery will then supply the load its required power. This is called "parallel operation" (see fig. 2). With substantially discharged batteries, the rectifier unit at first operates in the I-branch of the IU-characteristic line, whereby the charging...
Open the catalog to page 4BENNING World Class Power Solutions safe, reliable, powerful Rectifier series Thyrotronic The Thyrotronic series consists mainly of a thyristor-controlled power unit and a microprocessor-controlled monitoring and control unit. The following main components are included: • mains input with contactor • mains transformer with separate windings • fully controlled 6 pulse three phase bridge with semi conductor protection fuse (working primarily as battery inverse polarity protection) • smoothing chokes and capacitor bank to reduce ripple • control unit with digital setpoint setting • digital...
Open the catalog to page 5BENNING World Class Power Solutions THYROTRONIC comprehensive alarm and monitoring concept Functions of the signalling and monitoring unit: In the rectifiers of the Thyrotronic range a very large monitoring concept with the following functions is included as standard: Mains monitoring In case of a mains failure, an electronic regulator block is initiated and the LED and the "mains failure relay" will be activated. If the mains voltage returns the unit is automatically switched on after a set time. Charger output monitoring The charger output monitoring is a current-dependent low voltage...
Open the catalog to page 6BENNING World Class Power Solutions THYROTRONIC technical data Technical data Mains input Input voltage Input current Frequency Power factor Rectifier output Output voltage Output current Output current adjustment range Current accuracy Characteristic Boost voltage Float voltage Equalize voltage (VAC) 230 ± 10 % 1-phase 3x400 ± 10 % 3-phase (A) see type table (Hz) 50 ±5 % ~0.83 at nominal mains voltage and float charging (VDC) 24, 48, 60, 110, 125, 220 (A) see type table (%) 50 – 100 rectifier current limit (%) 0 – 50 battery charging current limit (%) ± 2 IU in acc. DIN41773 @ float and...
Open the catalog to page 7www.benninguk.com • www.benning.us BENNING worldwide P. R. China Benning Power Electronics (Beijing) Co., Ltd. Tongzhou Industrial Development Zone 1-B BeiEr Street 101113 BEIJING Tel.: +86 (0) 10 / 61 56 85 88 Fax: +86 (0) 10 / 61 50 62 00 E-mail: info@benning.cn Germany Benning Elektrotechnik und Elektronik GmbH & Co. KG Factory I: Münsterstr. 135-137 Factory II: Robert-Bosch-Str. 20 46397 BOCHOLT Tel.: +49 (0) 28 71 / 93-0 Fax: +49 (0) 28 71 / 9 32 97 E-mail: info@benning.de Spain Benning Conversión de Energía S.A. C/Pico de Santa Catalina 2 Pol. Ind. Los Linares 28970 HUMANES, MADRID...
Open the catalog to page 8All Benning catalogs and technical brochures
-
ENERTRONIC T
8 Pages
-
UPS ENERTRONIC S
6 Pages
-
INVERTRONIC modular
7 Pages
-
INVERTRONIC compact
8 Pages
-
DC-Converter 3000lDC
7 Pages
-
Rectifier NPP
8 Pages
-
TRANSOTRONIC
6 Pages
-
TEBECHOP 4000
2 Pages
-
UPS ENERTRONIC L
8 Pages
-
UPS ENERTRONIC I
8 Pages
-
Tebevert III
6 Pages
-
Invertronic
8 Pages
-
DC-Converters
4 Pages
-
ADC modular