Switches
97Pages

{{requestButtons}}

Catalog excerpts

Switches - 2

Informations Technical data Basic designs On-Off switches, Changeover switches Star-Delta switches Multi speed switches Control switches Voltmeter selector switches, Ammeter switches Gang switches Multi step switches Mini-Cam Switches Technical data On-Off switches, Changeover switches Star-Delta switches Control switches Voltmeter selector switches, Ammeter switches Gang switches, Multi step switches Main switches Switch disconnectors with padlock device Accessories Cam switches with padlock device Switch disconnectors On-Off switches Load switches On-Off switches Changeover switches...

Open the catalog to page 2
Switches - 3

- - Cam Switches Ratings Protection degree from front in mounted position Rated current Therm. Ith open AC21 A A Designs Panel moun. Single hole mount. Ø22,5mm M10H, M20 IP65 with Plate without Plate IP40 IP65 IP65 Cam switches can be used for virtually all purposes, e.g. as motor, main, control or instrument switches. Over and above the switching programs mentioned in the list, an effectively limitless number of special programs can be implemented. Load switches are primarily employed where resistive or slightly inductive current loads are to be switched on and off, or switching takes...

Open the catalog to page 3
Switches - 4

Designs Base mounting IP40 Plastic enclosed Motor switch ..P.. IP40 horizontal, IP65 enclosed ..PF.. IP65 IP65 Ordering SWITCH TYPE DESIGN SWITCH PROGRAM NUMBER OF STEPS NUMBER OF POLES M10H E A3+GFP 20A Panel mounting On-Off-switch 3-pole + large front plate On-Off-switch Changeover switch with Off position Changeover switch without Off position Changeover switch with spring return to Off Reversing switch Star-Delta-switch Multi speed switch Start switch Stop switch Voltmeter selector switch Ammeter selector switch Gang switch Multi step switch without Off position Multi step switch with...

Open the catalog to page 4
Switches - 5

Protection degree from front in mounted position Rated current Therm. Ith open AC21 A A Main Switch Emergency Stop Panel mounting Single hole mount. Base mounting Ø22,5mm with door coupling IP66 IP66 adjust. installation depth IP66 Plate Switch disconnector mm Switch disconnector LT.. 20 - 160A Switch disconnectors are to be used as an ON-OFF-switch where a high breaking capacity with high contact pressure and in fact better short circuit behavior is necessary. These applications are: Main switches according to IEC/EN 60204 respectively VDE0113 with interlocking device, terminal protection...

Open the catalog to page 5
Switches - 6

Main Switch Emergency Stop Base mounting w. for Distribution door coupling Boards depth not adjustable IP40 IP66 Main Switch Panel mounting Base mounting with door coupling IP66 Switch Disconnectors Panel mounting for Distribution Boards IP66 IP40 Switch program On-Off Switch 3-pole On-Off Switch 4-pole On-Off Switch 6-pole On-Off Switch 8-pole Changeover Switches 3-pole Changeover Switches 4-pole On-Off Switch 3-pole On-Off Switch 4-pole

Open the catalog to page 6
Switches - 7

- Cam Switches Panel mounting designs Switches of the panel mounting designs listed below have protection from front IP40. Where a shaft seal (appendix +WD) is used, the protection is increased to IP54. Use of a moisture proofing cap (appendix +FR) results in an increase in rear protection to IP54. In the standard version, the switches are delivered with a square escutcheon plate and black twist knob. Forward mounting is possible for some of the design E switches. The position of the terminals of the standard switches is left and right, at switch M10H the terminals are above and below....

Open the catalog to page 7
Switches - 8

- Cam Switches Base mounting designs Switches of the designs listed below have protection from front IP40. When a shaft seal (appendix +WD) is used, the front protection type is increased to IP54. In the standard version, the switches are delivered with a square escutcheon plate and black twist knob (design SMA with grey cover and grey toggle knob). Door couplings are advisable for switchgear cabinets with hinged doors. The position of the terminals of the standard switches is left and right, at switch M10H the terminals are above and below. Where a knob insert is turned by 90° (can easily...

Open the catalog to page 8
Switches - 9

- Cam Switches Plastic enclosed switches Cast aluminium enclosed switches The switches, which have durable plastic enclosures, are intended for wall mounting or attachment to machines. In the standard version, they are supplied with a light-grey enclosure, square escutcheon plate, black markings on a silver background, and a black twist knob. Other colours and colour combinations are available for most enclosure types. It is not possible to mount an additional rectangular plate. The enclosure base is equipped with 4 entry glands with heavy-gauge conduit threads (see drawings). In all types...

Open the catalog to page 9
Switches - 10

- Cam Switches Switching programs Description Wiring diagram Switching angle Number of cells Type ↓ Size ↓ AC21 Switch program Escutcheon plate 132 4-pole 4. pole early make Ordering example: AC21 250A panel mounting, On-Off-switch 6-pole, Escutcheon plate OFF - ON 1) Plastic enclosed switches are delivered with switch type M10. 2) Cast enclosed switches are delivered with switch type N32. D371E

Open the catalog to page 10
Switches - 11

- Cam Switches Switching programs Description Wiring diagram Switching angle Number of cells Type ↓ Size ↓ AC21 Switch program Escutcheon plate 4-pole 4. pole early make Ordering example: AC21 250A panel mounting, changeover switch 6-pole, Escutcheon plate 1 - OFF - 2 1) Plastic enclosed switches are delivered with switch type M10. 2) Cast enclosed switches are delivered with switch type N32. 10

Open the catalog to page 11
Switches - 12

- Cam Switches Switching programs Description Wiring diagram Switching angle Number of cells Type ↓ Size ↓ AC21 Switch program Escutcheon plate Changeover switches without off W 132 4-pole 4. pole early make Ordering example: AC21 250A panel mounting, changeover switch without off 6-pole, 1) Plastic enclosed switches are delivered with switch type M10. 2) Cast enclosed switches are delivered with switch type N32. D371E

Open the catalog to page 12
Switches - 13

- Cam Switches Switching programs Description Wiring diagram Switching angle Number of cells Type ↓ Size ↓ AC21 Switch program Escutcheon plate 3-pole position 1 latched position 2 with spring return to off 3-pole with spring return from both sides to off 2-pole position 1 latched position 2 with spring return to off 2-pole with spring return from both sides to off 2-pole without off cross switch Ordering example: AC21 63A base mounting, reversing switch 3-pole, position 2 with spring to off N40 V WU3R1 1) Plastic enclosed switches are delivered with switch type M10. 2) Cast enclosed...