General Overview
This document provides detailed technical data and specifications for contactors and motor starters, including mini contactors, reversing contactors, and contactor relays. It covers approvals, technical information, and mounting instructions necessary for proper installation and operation.
Approvals
The document outlines various approvals and certifications such as UL, SEV, GOST, and CCC. It emphasizes the importance of CE-Marking for compliance with EEC Directives, including the Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC.
Technical Information
Key specifications include auxiliary contact marking, resistance to climatic conditions, and short circuit protection. The document specifies protection degrees according to IEC 60947-1, with IP ratings for protection against solids and water.
Mounting Information
Instructions for mounting positions and terminal connections are provided, including tightening torque specifications for various screw types and sizes.
Mini Contactors and Relays
Details on mini contactors, including 4-pole AC operated relays, are provided. Ratings, thermal contacts, coil voltages, auxiliary contact blocks, and wiring diagrams are included.
Dimensions and Accessories
Dimensions for contactors and relays are included, along with a list of available accessories. Tables for selecting appropriate components based on application requirements are provided.
Specifications
Detailed specifications for mini contactors and relays include operational current, power ratings, and voltage requirements. Rated operational current for general use and AC motors at various voltages and frequencies is specified.
Procedures
Instructions for using suppressor units to protect against voltage peaks are provided, along with switching time calculations including release time and arc duration.
Standards and Norms
Compliance with standards such as UL508, IEC 947-5-1, VDE 0660, and EN 60947-5-1 is referenced. Pollution degrees and comparative tracking index (CTI) requirements for printed circuit boards are specified.
Recommendations
Recommendations include using specific coil voltages and configurations for optimal performance, and integrated coil suppressors for enhanced reliability.
Technical Data
Technical data for various contactor models includes dimensions, power consumption, and mechanical life. Tables with detailed ratings for operational current, voltage, and power for both AC and DC operated contactors are included.
Key Data from Tables
Tables list rated operational power for three-phase motors at different voltages and frequencies, as well as fuse and short-circuit current ratings. Specifications for auxiliary contacts, including heavy and standard pilot duty ratings, are provided.
Star-Delta Starters Overview
Specifications and configurations for Star-Delta Starters, including open and enclosed types, accessories, and related components, are detailed. Ratings, coil voltages, and overload relay compatibility are covered.
Specifications
Starters are rated for different power levels and voltages, with specific models for various operational requirements. Rated operational current and power for different voltage levels are listed.
Enclosures
Star-Delta Starters are available in plastic and sheet steel enclosures, offering IP65 and IP54 protection levels, respectively.
Accessories and Components
Details on accessories such as auxiliary contacts, electronic timers, and connectors are provided for customizing starters to specific needs.
Reversing Contactors
Reversing contactors with mechanical interlock are described, including ratings and configurations for motor direction reversal applications.
Pole Changing Starters
Pole changing starters are outlined, highlighting their ability to switch between different motor speeds.
Technical Data
Technical data according to international standards such as IEC 947-4-1 and VDE 0660 is provided, including rated insulation voltage, operational current, and power consumption.
Wiring Diagrams and Dimensions
Wiring diagrams and dimensions are provided to assist in installation and integration of starters into existing systems.
Conclusion
This document serves as a comprehensive guide for selecting, installing, and maintaining contactors and motor starters, ensuring compliance with international standards and safety regulations.
See more

Catalog excerpts

Contactors Motor-Starters-2

Index Page Mini Contactors Mini Contactors Interface Contactors Mini Reversing Contactors Technical Information Contactor Relays Contactor Relays Technical Information Contactors Overview Capacitor Switching Contactors Technical Information Star-Delta Starters Reversing Contactors Pole Changing Starters Technical Information Technical Information Overload Relays Thermal Overload Relays Technical Information Modular Contactors Technical Information Alphabetical Index Detailed Table of Contents may be found at beginning of each section Technical data, dimension sketches, illustrations and weights...

 Open the catalog to page 2
Contactors Motor-Starters-3

General Test Authorities, Registration Mark, Approvals Low voltage switchgear from Benedict GmbH is built and tested to national and international specifications. All devices suit all important specifications without any test obligation, like VDE, BS and also relative to IEC Recommendations and to European Standards like IEC 947 and EN 60947. It is for this reason of our Low voltage switchgear is used all over the world. In order to provide special versions, limitations to the max. voltages, currents and power ratings or special markings are sometimes necessary. The manufacturer has to sign his...

 Open the catalog to page 3
Contactors Motor-Starters-4

Approvals Country North America Russia GOST CENELEC CB-Certificates Type Mini Contactors, Reversing Contactors K1 and Accessories K1-07D..(=) K1-07L..(=) K1-07F..(=) Contactor Relays Series K3 and KG3 K3-07A..(=) K3-07D..(=) o In standard version approved - Not provided for test till now

 Open the catalog to page 4
Contactors Motor-Starters-5

Approvals Country North America Russia GOST CENELEC CB-Certificates Thermal Overload Relays U3/32 U3/42 U3/74 o In standard version approved - Not provided for test till now These data are important for UL-inspecting engineers. Devices Contactors Reversing Contactors Control Relays, Accessories NLDX NLDX NKCR Thermal Overload Relays Cam Switches Circuit Breakers as Manual Motor Controller NKCR NLRV NLRV Circuit Breakers as Combination Motor Controller Bus Bar Assemblies Accessories NKJH NLRV NKCR

 Open the catalog to page 5
Contactors Motor-Starters-6

Technical Information Degree of protection acc. to IEC 60947-1 Protection ratings are prefixed by the internationally agreed letters IP followed by two digits. Short description Protected against dripping water Dripping water (vertically falling drops) shall have no harmful effect. Protected against dripping water when tilted up to 15° Vertically dripping water shall have no harmful effect when the enclosure is tilted at any angle up to 15° from its normal position. Protected against spraying water Water falling as a spray at an angle up to 60° from the vertical shall have no harmful effect....

 Open the catalog to page 6
Contactors Motor-Starters-7

Technical Information Mounting positions of contactors K1-.. Terminal screws Devices Type Kind of connection Screw with Screw with washer clamp box Screw driver Tightening torque Mini Contactors, all conductors Auxiliary conductor All devices Contactor Relays, all conductors K(G)3-07.. Contactors Main conductor Accessories HK, HKM HA, HN, K2-.., HB.. Thermal Overload Relays Main conductor Contactors for Distribution Boards Conductors R20, R25 R40, R63 K1R

 Open the catalog to page 7
Contactors Motor-Starters-8

Mini Contactors Mini Contactor Relays 4-pole Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors Mini Contactors With Solder Pins Coil voltages Mini Reversing Contactors Auxiliary Contact Blocks Technical Data

 Open the catalog to page 8
Contactors Motor-Starters-9

Mini Contactor Relays 4-pole 4-pole, With Screw Terminals Type Coil voltage 1; Pack Weight Auxiliary Contact Blocks For Contactor Relays Ratings Thermal Pack Weight Wiring Diagrams Distinc. Number according to EN50011 for Contactor Relay with Auxiliary Contact Block Preferable combinations with distinctive letter "E" according to DIN EN 50011 1) Other coil voltages see page 12 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts 3) with built-in coil suppressor (varistor)

 Open the catalog to page 9
Contactors Motor-Starters-10

Type Coil voltage 1) Number Blocks 4-pole, With Screw Terminals, Coil 2,5W Pack Weight pes. kg/pc. Wiring Diagrams 4-pole, With Screw Terminals, Coil 1,5W, 19 to 30V DC with suppressor3) 1) Other coil voltages on request 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts 3) with integrated coil suppressor (Transient Voltage Suppressor Diode)

 Open the catalog to page 10
Contactors Motor-Starters-11

Mini Contactors Power Ratings Built-in Additional 3-pole, With Screw Terminals 4-pole, With Screw Terminals Type Coil voltage 1; Pack Weight Auxiliary Contact Blocks for Contactors K1 Pack Weight Wiring Diagrams Contactors with Auxiliary Contact Block Prefer combinations according to EN50012 Suppressor Units for Contactors K1 Voltage Range Pack Weight 1) Other coil voltages see page 12 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts 3) with built-in coil suppressor (varistor)

 Open the catalog to page 11
Contactors Motor-Starters-12

Built Additional Overload 3-pole, With Screw Terminals, Coil 2,5W 4-pole, With Screw Terminals, Coil 2,5W Pack Weight 3-pole, With Screw Terminals, Coil 1,5W, 19 to 30V DC with suppressor3> Wiring Diagrams 1) Other coil voltages on request 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA) Positively guided contacts 3) with integrated coil suppressor (Transient Voltage Suppressor Diode)

 Open the catalog to page 12
Contactors Motor-Starters-13

Mini Contactors Power Ratings Built Additional Type Coil voltage 1; Pack Weight 3-pole, with Fast On Tab Connectors 1 x 6,3mm or 2 x 2,8mm 3-pole, with Solder Pins 01,15 for Printed Circuit Applications 4-pole, with Solder Pins 01,15 for Printed Circuit Applications Coil voltages for AC operated contactors Standard voltages in bold type letters Operating range of magnet-coils: 0,85 x Us (min. value of rated control voltage) up to 1,1 x Us (max. value of rated control voltage) 1) Other coil voltages see page 12 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.