video corpo

RDC121
7Pages

{{requestButtons}}

Catalog excerpts

RDC121 - 1

Differential Current Sensor for stationary applications acc. to the standard IEC62955 K-No.: 30028 Customer: Standard type Description • Fluxgate current sensor with toroidal core • PCB mounting Applications Mainly used for stationary and mobile applications: • IC-CPD • Wallbox Excellent accuracy AEC-Q qualified components Switching open-collector outputs Compact design Electrical data – Ratings IP IΔN1 IΔN1, tolerance Primary nominal RMS current (1phase / 3phase) Rated residual operating current 1 Trip tolerance 1 Scaling factor of the DC component IΔN1 (for monitoring purpose only!) Recovery current level for IΔN1 (absolute value DC) Accuracy – Dynamic performance data IΔN,max X fBW (IΔN1) Max. measuring range (peak) Resolution (@ IΔN, ΘA = 25°C) Frequency range Ambient operation temperature Ambient storage temperature(4) Mass Supply voltage Consumption current Clearance (primary to secondary) Creepage (primary to secondary) EN/IEC 61709 / SN 29500(6) (MIL-HDBK-217F)(6) Firmware General data ϑA ϑStorage m VCC ICC Sclear, ps Screep, ps FIT SW °C °C 21 g 4.8 5 5.2 V 38 45 mA not applicable if isolated cable is used(5) not applicable if isolated cable is used(5) 1529 fit (6349) D596 V1.08 (3) Switching time of a standard relay (t = 20ms) is considered. (4) see VAC M-sheet 3101; storage temperature inside cardboard packaging (5) Constructed, manufactured and tested in accordance with IEC60664-1:2007 Isolated wires are preferred to fulfill the insulation coordination acc. to IEC 62955:2018, it is necessary to use insulated primary conductors that meet the requirements of the basic insulation for the rated voltage. If isolated primary conductors are used, the isolation coordination is acc. to: Reinforced insulation, Insulation material group 1, Pollution degree 2 and overvoltage category III. (6) The results are valid under following conditions: 55°C mean component ambient temperature by continuous operation (8760h per year); Environment condition: ground mobile, no dust or harmful substances, according to IEC61709; Fit equals one failure per 10^9 component hours. General description of sensor function: The sensor is sensitive to DC currents and can be used for fault current detection in EV-charging applications according IEC 62955:2018. In the event of a DC fault current, PIN3 and PIN4 will change its state from a low level to a high impedance state. Error conditions (e.g. an internal error) are signaled on PIN 1 (ERROR-OUT). The sensor only fulfills the switch-off characteristic of the IEC62955 standard (monitoring the residual current). An additional driver-circuit must be used for driving RCBO, RCCB or circuit breaker as defined in IEC62955. The sensor’s outputs are limited to max. 40V/50mA! Datum Änderung Patents added on sheet 1. CN-21-290 23.09.20 Final test: change value of TC1 and TC2; remove LV2. Minor change. Designer: MB Editor.: R&D-PD-NPI D MC-PM: BZ 11.10.2021 Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden. Any offenders are

Open the catalog to page 1
RDC121 - 2

Differential Current Sensor for stationary applications acc. to the standard IEC62955 K-No.: 30028 Customer: Standard type Mechanical outline (mm): Page 2 of 7 General tolerances DIN ISO 2768-c 4641-X904 F DC Content of Data-MatrixCode is: benvac, 4641X904, F, DC Datecode Format: [YWW] Example: J04: 2017, Week 4 PIN 1  ERROR-OUT (open collector output) If no system fault is detected, the output PIN 1 is a low level (GND). If a system fault is detected, PIN 1 is high impedance. In this case, PINs 3 and 4 will be set to a high impedance state (see tab. 1). A function test including an offset...

Open the catalog to page 2
RDC121 - 3

Differential Current Sensor for stationary applications acc. to the standard IEC62955 K-No.: 30028 Customer: Standard type Typical application diagram: power contactor driver circuit working voltage to driver , control electronics , control electronics e.g. charge Absolute maximum Ratings(6): Min VCE IC VCC UMAX VTEST-IN, low VTEST-IN, high Collector-Emitter voltage (PINs 1, 3 and 4) Collector current (PINs 1, 3 and 4) Maximum supply voltage (without function) Maximum rated voltage of primary conductors (AC rms) TEST-IN Input Voltage, low level TEST-IN Input Voltage, high level Stresses...

Open the catalog to page 3
RDC121 - 4

Differential Current Sensor for stationary applications acc. to the standard IEC62955 K-No.: 30028 Customer: Standard type Final Tests: (Measurements after temperature balance of the samples at room temperature, SC=significant characteristic) Min. 4.9 Vcc Supply voltage 38.0 Icc Supply current 2.8 TEST-IN (SC) TEST-IN voltage 0 X6-OUT (normal) X6-OUT voltage 0 X30-OUT (normal) X30-OUT voltage 0 ERROR-OUT (normal) ERROR-OUT voltage 4.9 X6-OUT (activated) X6-OUT voltage activated @5V, 1kΩ (pull-up)* 4.9 X30-OUT (activated) X30-OUT voltage activated @5V, 1kΩ (pull-up)* ERROR-OUT 4.9 ERROR-OUT...

Open the catalog to page 4
RDC121 - 5

Differential Current Sensor for stationary applications acc. to the standard IEC62955 K-No.: 30028 Customer: Standard type Requalification Tests: (replicated every year, Precondition acc. to M3238) ÛW, prim-sec Impulse test (1.2µs/50µs waveform) PIN 1-8 vs. insulated primary wire 5 pulse  polarity +, 5 pulse  polarity - Test voltage, 60s PIN 1-8 vs. insulated primary wire Partial discharge voltage (extinction) PIN 1-8 vs. insulated primary wire Partial discharge voltage (extinction) PIN 1-8 vs. insulated primary wire Other instructions: - Temperature of the primary conductor should not...

Open the catalog to page 5
RDC121 - 6

Differential Current Sensor for stationary applications acc. to the standard IEC62955 K-No.: 30028 Customer: Standard type Fig. 2: Power-Up timing diagram Normal condition High impedance High impedance High impedance High impedance High impedance Error, system fault All other conditions not mentioned in the table are not possible. If these conditions occur, the sensor is in unknown state and describes an Error. Table 1: Possible output states Editor.: R&D-PD-NPI D Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written...

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RCMB123

    7 Pages

  5. RCMB 121-2

    7 Pages

  6. RCMB121-1

    7 Pages

  7. RDC104-4

    6 Pages

  8. 300ST

    4 Pages

  9. 400ST

    4 Pages

  10. USC710D4

    6 Pages

  11. DI-1DL

    4 Pages

  12. DI-2

    4 Pages