RDC104-4 - 1

RDC104-4 DC sensitive residual current monitoring module for electric vehicle charging systems

Open the catalog to page 1
RDC104-4 - 2

DC sensitive residual current monitoring module for electric vehicle charging systems Product description The residual current monitoring module RDC104-4 is used in combination with a measuring current transformer CTBC17 or W15BS and a type A RCD which has to be provided in the installation for DC fault current monitoring of AC charging systems for electric vehicles in which AC or DC fault currents can occur. The rated voltage Un is 250 V and the rated current (charging current) In = 1 x 48 A/3 x 32 A. The RDC104-4 is suitable for integration into a charging unit Mode 3 (AC) as a RDC-M...

Open the catalog to page 2
RDC104-4 - 3

DC sensitive residual current monitoring module RDC104-4 Wiring diagram Wiring diagram measuring current transformer of the series W15BS Wallbox zum Verbraucher/ to load driver circuit Caution! Cable break due to excessively bent/ mechanically stressed cable! Fasten the cable with remaining length according to bending radius. Residual current sensor Bending radius of the cable: – 40 mm (once) – 75 mm (several times) Laderegler/ Charge controller Test Release Dimension diagram Referenzbohrung Reference drilling 1,50 • = Wicklungsanfang/Start of winding Test

Open the catalog to page 3
RDC104-4 - 4

DC sensitive residual current monitoring module RDC104-4 Connection socket measuring current transformer 1,6 mm 2,5 mm Leiterplatte/ circuit board 2,5 mm Description Side view RDC104-4 Recommended drilling diameter: ø 1,1 mm Evaluating board Test winding (start of winding) Test winding Measuring winding 2 (start of winding) Measuring winding 1 (start of winding) Measuring winding 2 Measuring winding 1 Recommended drilling diameter pins: Ø 0,9 mm Input test activated by GND for 30 ms…1.2 s 2 - Error Fault output (active low) LOW: no system fault HIGH: system fault 3 - DC2 IEC: current output...

Open the catalog to page 4
RDC104-4 - 5

DC sensitive residual current monitoring module RDC104-4 Technical data Primary circuit (monitored circuit) Control input (TEST) Rated voltage Un Rated current In Short-term continuous current In for 1 s Switching thresholds LOW: activated state HIGH: deactivated state HIGH: 3.1… 5.5 V LOW: 0… 0.6 V Insulation coordination according to IEC 60664-1/IEC 60664-3 Definitions: Measuring circuit IC1 (L1, L2, L3, N) Electronics IC2 (a…f, Test, Error, DC1, DC2, Vcc, GND, PWM) Rated voltage 250 V Overvoltage category (OVC) III Rated impulse voltage: IC1/IC2 4 kV Rated insulation voltage: IC1/IC2 250...

Open the catalog to page 5
RDC104-4 - 6

„Test“ timing diagram 40 ms…1.2 s Internal test current M1: DC1 = HIGH M2: DC2 = HIGH M3: DC1 / DC 2 = LOW t1 = 10 ms or 1000 ms Optional time to check for welded contacts. 10 ms if check is disabled. t2 = 500 ms Time for offset calibration. t3 = 0 ms to 50 ms Optional time required to store the offset calibration value. Depends on the difference to the value already stored in memory. Timing-Diagramm „Alarm“ Idn > 5 mA DC Fault current DC1, DC2 Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • info@bender.de • www.bender.de BENDER Group...

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. 300ST

    4 Pages

  9. 400ST

    4 Pages

  10. USC710D4

    6 Pages

  11. DI-1DL

    4 Pages

  12. DI-2

    4 Pages