video corpo

The Power in Electrical Safety
404Pages

{{requestButtons}}

Catalog excerpts

The Power in Electrical Safety - 1

Main Catalogue Edition 2016/2017

Open the catalog to page 1
The Power in Electrical Safety - 2

Quality System Certified ijsatf ISO 9001 Main Catalogue Edition 2016/2017 Bender GmbH & Co. KG Londorfer Str. 65 D-35305 Grunberg P.O.Box 1161 D-35301 Grunberg Tel. +49 6401 807-0 Fax +49 6401 807-259 E mail: info@bender.de Internet: www.bender.de Subject to change! - © Bender GmbH & Co. KG, Germany The catalogue and the articles and illustrations which it contains are protected by copyright. Distribution, translation, microfilming and storing in electronic systems, particularly for commercial purposes, are not permitted without prior permission from the author. We accept no liability for...

Open the catalog to page 2
The Power in Electrical Safety - 3

Insulation monitoring devices Equipment for insulation fault location Power Quality and Energy Measurement Measuring and monitoring relays Residual current monitoring systems System components Coupling devices Measuring current transformers Transformers Measuring transducers Power supply units Measuring instruments Interface converters Interface repeaters COMTRAXX® Gateways COMTRAXX® Alarm indicator and test combinations COMTRAXX® condition monitors Visualisation Switching equipment ATICS® transfer switching and monitoring devices Test systems UNIMET® Safety analyser Annex Standards and...

Open the catalog to page 3
The Power in Electrical Safety - 4

The Power in Electrical Safety

Open the catalog to page 4
The Power in Electrical Safety - 5

In the past 70 years we have learnt thinking ahead in a strategic and forward-looking way and to consider today what customers are going to need tomorrow. Innovative solutions und service activities, excellent know-how global expertise when it comes to electrical safety provide answers to the challenges of various application areas. As a global market and technology leader we underline this by our quality promise 5foryou. With over 700 employees we are globally present in over 70 countries. Since January 2012 we provide a five-year warranty for “5forU”-relevant devices registered not later...

Open the catalog to page 5
The Power in Electrical Safety - 6

Monitoring and analysis made easy More information on powerscout.bender.de

Open the catalog to page 6
The Power in Electrical Safety - 7

^ Simple setup ✓ Long-term analysis ✓ Visualisations ✓ Automated reports ✓ Across locations ✓ Central testing and monitoring of the electrical installation and equipment (DGUV Vorschrift 3 (German Social Accident Insurance Regulation 3)) ✓ No local software installation required

Open the catalog to page 7
The Power in Electrical Safety - 9

Insulation monitoring devices Equipment for insulation fault location Power Quality and Energy Measurement Measuring and monitoring relays Residual current monitoring systems System components Coupling devices Measuring current transformers Transformers Measuring transducers Power supply units Measuring instruments Interface converters Interface repeaters COMTRAXX® Gateways COMTRAXX® Alarm indicator and test combinations COMTRAXX® condition monitors Visualisation Switching equipment ATICS® transfer switching and monitoring devices Test systems UNIMET® Safety analyser Annex Standards and...

Open the catalog to page 9
The Power in Electrical Safety - 10

Overviewinsulation monitoring devices ISOMETER® ISOMETER® iso685-... Insulation monitoring devices | Device overview

Open the catalog to page 10
The Power in Electrical Safety - 11

Suitable system components Z. BENDER 2016/2017 Insulation monitoring devices | Device overview

Open the catalog to page 11
The Power in Electrical Safety - 12

Overviewinsulation monitoring devices ISOMETER® ISOMETER® ISOMETER® Insulation monitoring devices | Device overview

Open the catalog to page 12
The Power in Electrical Safety - 13

Suitable system components Z. BENDER 2016/2017 Insulation monitoring devices | Device overview

Open the catalog to page 13
The Power in Electrical Safety - 14

Overviewinsulation monitoring devices ISOMETER® cooo ooo • • • ISOMETER® isoPV Insulation monitoring devices | Device overview

Open the catalog to page 14
The Power in Electrical Safety - 15

Suitable system components Z. BENDER 2016/2017 Insulation monitoring devices | Device overview

Open the catalog to page 15
The Power in Electrical Safety - 16

ISOMETER® IR420-D4Insulation monitoring device for unearthed AC control circuits (IT systems) | Typical applications • AC control circuits in the industrial sector, mechanical engineering, power plants, elevators, automation systems etc. • AC control and auxiliary circuits in accordance with DIN EN 60204-1 "Electrical equipment of machines” IEC 60204-1, EN 60204-1 • AC auxiliary circuits in accordance with DIN VDE 0100-725 • Smaller AC IT systems such as lighting systems, mobile generators | Approvals • Insulation monitoring for IT control circuits AC 0...300 V • Two separately adjustable...

Open the catalog to page 16
The Power in Electrical Safety - 17

Rated insulation voltage Rated impulse voltage/pollution degree Supply voltage Power consumption Switching elements Number of switching elements Operating principle Electrical service life, number of cycles Contact data acc. to IEC 60947-5-1 Utilisation category Rated operational voltage Rated operational current Minimum contact rating 2x 1 changeover contact NC/N/O operation (N/O operation)* 10,000 IT system being monitored Nominal system voltage Un Operating temperature Response values Response value Ran1 (Alarm 1) Response value Ran2 (Alarm 2) Preset mode Un < 72 V Ran1 (Alarm 1) = Un >...

Open the catalog to page 17
The Power in Electrical Safety - 18

LED power “ON”, (flashes in case of interruption of the connecting leads E/KE or L1/L2). Alarm LED “AL1”, lights when the value falls below the set response value Alarm 1 and flashes in case of interruption of the connecting leads E/KE or L1/L2). Alarm LED “AL2”, lights when the value falls below the set response value Alarm 2 and flashes in case of interruption of the connecting leads E/KE or L1/L2). Test button “T”: to call up the self test. Arrow up button: arameter change, to move up in the menu p Reset button “R”: to delete stored insulation fault alarms Arrow down button: arameter...

Open the catalog to page 18
The Power in Electrical Safety - 19

Insulation monitoring device for unearthed AC and DC systems | Typical applications • AC and DC control and auxiliary circuits in accordance with DIN EN 60204-1, "Electrical equipment of machines”, IEC 60204-1, EN 60204-1 • DC auxiliary circuits in accordance with DIN VDE 0100-725 • Insulation monitoring for AC and DC systems (IT systems) • Response values, adjustable 10...200 kO • LEDs: Power On LED, alarm LED to signal insulation faults • Internal combined test and reset button • Connection external reset button • Alarm relay with one potential-free changeover contact • N/C operation •...

Open the catalog to page 19

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages