LINETRAXX® VME421H Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems without separate supply voltage

Open the catalog to page 1
LINETRAXX® VME421H - 2

Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems without separate supply voltage Product description The voltage monitor VME421H monitors AC/DC systems in the frequency range of DC/15…460 Hz for undervoltage, overvoltage, underfrequency or overfrequency. Device variant -1 is suitable for the nominal voltage range Un = 9.6…150 V, device variant -2 for Un = 70…300 V. The supply voltage is taken from the nominal voltage being monitored Un. In order to meet the requirements of the applicable standards, customised parameter settings must...

Open the catalog to page 2
LINETRAXX® VME421H - 3

Monitoring relay for undervoltage, overvoltage and frequency LINETRAXX® VME421H Operating elements 1 - ower On LED “ON” (green); lights when supply voltage is applied P and flashes in the event of system fault alarm 2 - larm LED “AL1” (yellow), lights when the set response value A >U/f is exceeded and flashes in the event of system fault alarm 3 - larm LED “AL2” (yellow), lights when the value falls below A the set response vlaue f and flashes in the event of system fault alarm 4 - Multi-functional LC display 5 - est button “T”: T A rrow up button: To change the measured value display, move...

Open the catalog to page 3
LINETRAXX® VME421H - 4

Relay for undervoltage, overvoltage and frequency LINETRAXX® VME421H Timing diagram voltage monitoring toff - Delay on release

Open the catalog to page 4
LINETRAXX® VME421H - 5

Monitoring relay for undervoltage, overvoltage and frequency LINETRAXX® VME421H Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated insulation voltage Rated impulse voltage/overvoltage category Pollution degree Protective separation (reinforced insulation) between: Voltage test acc. to IEC 61010-1 Supply voltage VME421H-D-1: Supply voltage Us VME421H-D-2: Supply voltage Us Power consumption none (internally supplied by Un: 9,6…150 V) none (internally supplied by Un: 70…300 V) ≤ 6 VA Measuring circuit Measuring range (rms value) (VME421H-D-1) Measuring range (rms...

Open the catalog to page 5
LINETRAXX® VME421H - 6

Ordering information Nominal system voltage 1) Un AC 9.6…150 V, 15…460 Hz 70…300 V, 15…460 Hz 1) Absolute values Dimension diagram XM421 Dimensions in mm Art. No. Mounting clip for screw mounting (1 piece per device) Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • info@bender.de • www.bender.de BENDER Group VME421H_D00141_02_D_XXEN / 12.2021 / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 12.2021 unless otherwise indica

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages