video corpo

LINETRAXX® CTUB100-Serie
10Pages

{{requestButtons}}

Catalog excerpts

LINETRAXX® CTUB100-Serie - 1

LINETRAXX® CTUB100 series AC/DC sensitive measuring current transformers (type B)

Open the catalog to page 1
LINETRAXX® CTUB100-Serie - 2

AC/DC sensitive measuring current transformers (type B) Product description The CTUB100 series measuring current transformers are combinations of CTBC… measuring current transformer cores and CTUB10… electronic modules, which convert AC and DC currents into an evaluable measurement signal. The measurement signals can be evaluated using devices of the RCMA420/423, RCMS460/490 or EDS440/EDS441LAB series. The measuring current transformers are connected to the respective devices via a 2- or 6-core cable. They can be used in DC, AC, and 3(N)AC systems. The CTUB101-CTBCxx measuring current...

Open the catalog to page 2
LINETRAXX® CTUB100-Serie - 3

Variants A measuring current transformer always consists of a measuring current transformer core and an electronic module, which is required for signal conversion and can be connected to an evaluator. Each electronic module can be combined with all measuring current transformer cores. Electronic modules • CTUB101 Electronic module for conversion of the residual current signal from the measuring current transformer core for the connection to RCM devices via terminals S1 and S2, supply voltage DC ±12 V • CTUB102 Electronic module for conversion of the residual current signal from the...

Open the catalog to page 3
LINETRAXX® CTUB100-Serie - 4

Wiring diagram 24V GND Power supply unit (STEP-PS…) + surge protection device * The measuring range must be selected according to the response value I∆N set on the RCMS460 or RCMA420/423 evaluator. If, however, a larger measuring range is selected, the resolution deteriorates. For the CTUB104, a selection of the measuring range is not required. Setting measuring range (not required for CTUB104) # 1 Potentiometer setting Response value RCMA/RCMS I∆n ≤ 0.1 A Measuring range peak 0…900 mA ** – The use of a type 2 surge protection device (SPD) is mandatory due to possible impulse voltages and...

Open the catalog to page 4
LINETRAXX® CTUB100-Serie - 5

System states: LED The LED indicates the system state by means of colours and lighting/flashing. LED System state Normal operating state The device is supplied with the specified voltage and the measuring current transformer core is connected to the electronic module. Device error The device is supplied with the specified voltage but there is no connection to the measuring current transformer core or some other device error has occurred. Dimension diagrams

Open the catalog to page 5
LINETRAXX® CTUB100-Serie - 7

Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Definitions: Measuring circuit (IC1) primary conductors routed through the current transformer Secondary (IC2) connections terminal block Rated insulation voltage 800 V Overvoltage category III Area of application ≤ 2000 m AMSL Rated impulse voltage: IC1/IC2 8 kV Rated insulation voltage (reinforced insulation): IC1/IC2 800 V Pollution degree 2 Name Scaling Max. voltage Max. connector length Output resistance Supply voltage CTUB101 Description Supply voltage Us Operating range of Us Ripple Us Power consumption CTUB102,...

Open the catalog to page 7
LINETRAXX® CTUB100-Serie - 8

Ordering details Suitable for evaluator Current transformer diameter Supply voltage Ordering details for accessories and spare parts Measuring current transformer cores Electronic modules Supply voltage Us Internal diameter Required terminals are included in the scope of delivery. Connecting cables are optionally available. P = full magnetic shield The measuring current transformers of the CTUB10x series comply with the requirements of the standard DIN EN 45545-2. Suitable system components Name DIN rail mounting clip for CTBC20 and CTBC20P DIN rail mounting clip for CTBC35 and CTBC35P...

Open the catalog to page 8
LINETRAXX® CTUB100-Serie - 9

Composition example of a measuring current transformer from the individual components = Measuring current transformer core: CTBC35 Measuring current transformer: CTUB101-CTBC35* * or connection to an evaluator, a complete measuring current transformer is required. Both components can be ordered separately F as spare parts. Installation instructions • Do not route any shielded cables through the measuring current transformer. • xisting protective conductors and low-resistance conductor loops must not be routed through the measuring current transformer! E Otherwise, high currents could be...

Open the catalog to page 9
LINETRAXX® CTUB100-Serie - 10

BENDER Group CTUB100 series_D00362_04_D_XXEN/06.2022 / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 06.2022 unless otherwise indicated. Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • info@bender.de • www

Open the catalog to page 10

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages