LINETRAXX® CTAC series Measuring current transformers Product description The highly sensitive CTAC series measuring current transformers in combination with RCM or RCMS series residual current monitors and evaluators convert AC currents into an evaluable measurement signal. They are also suitable for use in insulation fault location systems for IT systems (EDS). The current transformers measure the locating current generated by a PGH locating current injector or an ISOMETER® iso685. In combination with EDS series insulation fault locators, the locating current is converted into an...

Open the catalog to page 2
LINETRAXX® CTAC-Serie - 3

Measuring current transformers LINETRAXX® CTAC series

Open the catalog to page 3
LINETRAXX® CTAC-Serie - 4

Measuring current transformers LINETRAXX® CTAC series Installation instructions • Do not route any shielded cables through the measuring current transformer. • f the installation instructions are not followed, the tolerances and normative requirements of the connected monitoring devices may I not be fulfilled. PE Never route an existing protective conductor through the measuring current transformer. All current-carrying cables must be routed together through the measuring current transformer. The primary conductors may only be bent from the specified minimum distance. The minimum bending...

Open the catalog to page 4
LINETRAXX® CTAC-Serie - 5

Measuring current transformers LINETRAXX® CTAC series Technical data Insulation coordination acc. to IEC 60664-1 Rated insulation voltage Overvoltage category Rated impulse voltage/pollution degree Measuring current transformer circuit CTAC… Rated transformation ratio Kr600/1 Rated continuous thermal current* Icth 125 A Frequency range 15 Hz…100 kHz Rated short-time thermal current* Ith 2.4 kA/1 s Rated dynamic current* Idyn 6.0 kA/40 ms Rated current I CTAC20 at IΔn ≥ 30 mA 63 A CTAC20 at IΔn ≥ 300 mA 80 A CTAC35 at IΔn ≥ 30 mA 125 A CTAC35 at IΔn ≥ 300 mA 160 A CTAC60 at IΔn ≥ 30 mA 200 A...

Open the catalog to page 5
LINETRAXX® CTAC-Serie - 6

BENDER Group CTAC_D00386_03_D_XXEN / 09.2021 / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 09.2021 unless otherwise indicated. Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • info@bender.de • www

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages