ISOSCAN® EDS460/490 – EDS461/491 Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Open the catalog to page 1
ISOSCAN® EDS460-D/EDS461-D - 2

Insulation fault locators with control and display function for insulation fault location systems Product description The insulation fault locators ISOSCAN® EDS460/490 in combination with the ISOMETER® IRDH575 or the locating current injector PGH are applied for localising insulation faults in unearthed systems (IT systems). The locating current signals generated by the insulation monitoring device IRDH575 or the locating current injector PGH are detected by measuring current transformers and evaluated by the insulation fault locators. Up to 12 measuring current transformers can be...

Open the catalog to page 2
ISOSCAN® EDS460-D/EDS461-D - 3

Insulation fault locators ISOSCAN® EDS460/490 – EDS461/491 EDS461-D/-L and EDS491-D/-L In comparison to the device versions described above, these versions provide a higher response sensitivity. They are preferrably used in control circuits or in medical locations up to AC 230 (DC 220) V. Standards The ISOSCAN® EDS46… series complies with the requirements of the device standards: DIN EN 61557-8 (VDE 0413-8), EN 61557-8, IEC 61557-8, IEC 61326-2-4, DIN EN 60664-1 (VDE 0110-1), DIN EN 60664-3, DIN EN 61557-9, VDE 0413-9, IEC 61557-9, ASTM F1669M-96 (2007), ASTM F1207M-96 (2007) Overview of...

Open the catalog to page 3
ISOSCAN® EDS460-D/EDS461-D - 4

Insulation fault locators ISOSCAN® EDS460/490 - EDS461/491 Z BENDER Wiring diagram - Mains connection EDS460/461-D/-L and EDS490/491-D/-L 1 - Supply voltage Us (see ordering information), 6 A fuse recommended; two-pole fuses are required on IT systems 2 - Connection measuring current transformers kl___kl 2 3 - Serial interface RS-485 4 - External reset button “R" (N/O contact)* 5 - External test button T" (N/O contact)* 6 - Alarm relay 1 7 - Alarm relay 2 8 - Alarm relay: one N/O contact per channel (EDS490/491 only) 9 - Ron/off Termination of the serial RS-485 interface (A/B) with 120 Q *...

Open the catalog to page 4
ISOSCAN® EDS460-D/EDS461-D - 5

Insulation fault locators ISOSCAN® EDS460/490 – EDS461/491 Example for system set-up Example for system set-up Note: The DI-1 interface repeater only is required when the length of the cable exceeds 1200 m or when more than 32 devices are connected to the bus.

Open the catalog to page 5
ISOSCAN® EDS460-D/EDS461-D - 6

Insulation fault locators ISOSCAN® EDS460/490 – EDS461/491 Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 for versions with a supply voltage of AC/DC 70…276 V/AC 42…460 Hz Rated insulation voltage AC 250 V Rated impulse voltage/pollution degree 6 kV/3 Protective separation (reinforced insulation) between (A1, A2) - (k1, l…k12, R, T/R, T, A, B, ), Time response Response delay ton Delay on release toff Scanning time for all channels Displays, memory LEDs LC display 7-segment display History memory Password Language Fault memory alarm relay ON/ALARM (EDS4…-D)...

Open the catalog to page 6
ISOSCAN® EDS460-D/EDS461-D - 7

Insulation fault locators ISOSCAN® EDS460/490 - EDS461/491 Connection Connection screw-type terminals Multi-conductor connection (2 conductors with the same cross section): rigid/flexible 0.2.1.5/0.2.1.5 mm2 Other Operating mode Position of normal use Degree of protection, terminals (DIN EN 60529) Enclosure material Flammability class Screw mounting DIN rail mounting acc. to Weight ( )* factory setting Measuring range Supply voltage 11 Us aC dC

Open the catalog to page 7
ISOSCAN® EDS460-D/EDS461-D - 8

Insulation fault locators ISOSCAN® EDS460/490 - EDS461/491 Z BENDER Suitable system components

Open the catalog to page 8
ISOSCAN® EDS460-D/EDS461-D - 9

Insulation fault locators ISOSCAN® EDS460/490 – EDS461/491 Response sensitivity in relation to the system capacitance 3AC 400 V Explanatory notes on the response sensitivity The value of the maximum response sensitivity decreases in relation to the system leakage capacitance. The following maximum response values can be reached: 30 Ω/V with a system voltage of max. 20000 µFV (product of the nominal voltage and system leakage capacitance) Example: system voltage 230 V 20000 µFV/230 V = 87 µF 230 V x 30 Ω/V = 6.9 kΩ minimum response value at 87 µF system leakage capacitance Dimension diagrams...

Open the catalog to page 9
ISOSCAN® EDS460-D/EDS461-D - 10

BENDER Group EDS460-490_D00085_01_D_XXEN / 01.2017 / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the version that was valid at the time of printing. Bender GmbH & Co. KG P.O. Box 1161 • 35301 Gruenberg • Germany Londorfer Strasse 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-Mail: info@bender.de • w

Open the catalog to page 10

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages