video corpo

ISOMETER® isoRW425
6Pages

{{requestButtons}}

Catalog excerpts

ISOMETER® isoRW425 - 1

ISOMETER® isoRW425 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for railway applications up to 3(N)AC, AC/DC 400 V

Open the catalog to page 1
ISOMETER® isoRW425 - 2

Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for railway applications up to 3(N)AC, AC/DC 400 V Product description The ISOMETER® monitors the insulation resistance (R mode) or the insulation impedance (Z mode) of unearthed AC/DC main circuits (IT systems) with nominal system voltages of 3(N)AC, AC, AC/DC or DC 0…400 V. DC components existing in 3(N)AC, AC/DC systems do not influence the operating characteristics when a minimum load current of DC 10 mA flows. Due to the separate supply voltage, de-energised systems can also be monitored. The maximum...

Open the catalog to page 2
ISOMETER® isoRW425 - 3

AC/DC Operating elements 12 3 1 - LED "ON" (operation LED) flashes in case of interruption to the connecting wires E/KE, L1(+)/L2(-) or system faults. 2 - Alarm LED "AL1" lights when the values fall below the set response value Alarm 1 and flashes in case of interruption to the connecting wires E/KE, L1(+)/L2(-) or system faults as well as in the case of overvoltage (can be activated). 3 - Alarm LED "AL2" lights when the values fall below the set response value Alarm 2 and flashes in case of interruption to the connecting wires E/KE, L1(+)/L2(-) or system faults as well as in the case...

Open the catalog to page 3
ISOMETER® isoRW425 - 4

Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated voltage (A1, A2) - (11, 14, 24) 300 V Rated impulse withstand voltage 4 kV Rated voltage (L1/+, L2/-, E, KE, T/R, A, B) 400 V Rated impulse withstand voltage 6 kV Overvoltage category III Pollution degree 3 Protective separation (reinforced insulation) between (A1, A2) - (L1/+, L2/-, E, KE, T/R, A, B) - (11, 14, 24) Voltage tests according to IEC 61010-1 2.2 kV Supply voltage Voltage tests according to US Tolerance of US Frequency range US Power consumption IT system being monitored Nominal system voltage Un...

Open the catalog to page 4
ISOMETER® isoRW425 - 5

Ordering information Dimensions in mm Open the front plate cover in direction of arrow! Screw mounting Note: The upper mounting clip must be ordered separately (see ordering information).

Open the catalog to page 5
ISOMETER® isoRW425 - 6

BENDER Group isoRW425_D00052_01_D_XXEN / 07.2015 / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the current edition at the time of going to press. Bender GmbH & Co. KG Postfach 1161 • 35301 Gruenberg • Germany Londorfer Straße 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-mail: info@bender.de •

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages