ISOMETER® isoMED427x-(PT)
6Pages

{{requestButtons}}

Catalog excerpts

ISOMETER® isoMED427x-(PT) - 1

ISOMETER® isoMED427x-(PT) Insulation monitoring device for medical applications

Open the catalog to page 1
ISOMETER® isoMED427x-(PT) - 2

Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems Product description ISOMETER®s of the isoMED427x-(PT) series monitor the insulation resistance of a medical IT system with AC 70…264 V. In addition, the load current and the temperature of the IT system transformer are monitored. Alarms and measured values are provided to other bus devices via the BMS interface. For display and signalling purposes, the use of special alarm indicator and test combinations is recommended. After...

Open the catalog to page 2
ISOMETER® isoMED427x-(PT) - 3

Operating elements 3 1 - Power on LED 2 - Alarm LED 1 is lit: Below response value Ran 3 - Alarm LED 2 is lit: Response value % I or/and °C exceeded 4 - LC-Display 5 - T": Start a self test (2 s) " : Menu item up / increase value 6 - : Menu item down / decrease value 7 - tart menu mode (2 s) S Enter button: (< 1.5 s): ConArm menu item, submenu item, value. (> 2 s): Return to the next higher menu level Connection to the IT system to be monitored; supply voltage (see nameplate) via 6 A fuse Connection to measuring current transformer (STW2) Connection to external test button RS-485 interface,...

Open the catalog to page 3
ISOMETER® isoMED427x-(PT) - 4

Insulation coordination acc. to IEC 60664-1/-3 Definitions Measuring circuit (IC1) Control circuit (IC2) Output circuit (IC3) Rated voltage Overvoltage Operating altitude Rated impulse voltage IC1/(IC2-3) IC2/IC3 Rated insulation voltage IC1/(IC2-3) IC2/IC3 Pollution degree Protective separation between IC1/(IC2-3) IC2/IC3 Voltage test (routine test) according to IEC 61010-1 (IC1-2)/IC3 Temperature monitoring L1, L2 E, KE, Z, Z/k, l, T1, T2, A, B 11, 12, 14 250 V category III < 2000 m AMSL 4 kV 4 kV 250 V 250 V 3 Overvoltage category III, 300 V Overvoltage category III, 300 V 2.2 kV Supply...

Open the catalog to page 4
ISOMETER® isoMED427x-(PT) - 5

Connection type Push-wire terminals Nominal current ≤ 10 A Stripping length 10 mm Opening force 50 N Test opening, diameter 2.1 mm Connection properties: rigid 0.2…2.5 mm2 (AWG 24…14) flexible without ferrule 0.75…2.5 mm2 (AWG 19…14) flexible with ferrule 0.2…1.5 mm2 (AWG 24…16) Connection type Screw-type terminals Nominal current ≤ 10 A Tightening torque 0.5…0.6 Nm (5…7 lb-in) Cross section AWG 24…12 Stripping length 8 mm Connection properties: rigid / flexible 0.25…2.5 mm2 Flexible with ferrules with/without plastic sleeve 0.25…2.5 mm2 Multi-conductor rigid/flexible 0.2…1.5 mm2...

Open the catalog to page 5
ISOMETER® isoMED427x-(PT) - 6

Ordering information Supply voltage Us 1) Only this device has a Lloyds Register approval Type designation Mounting clip for screw mounting (1 piece per device) Passende Systemkomponenten Measuring current transformers Temperature sensor (PTC) Mounting frame Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • info@bender.de • www.bender.de BENDER Group isoMED427_D00440_00_D_XXEN/06.2022 / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 06.2022 unless otherwise indicated.

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages