video corpo

ISOMETER® isoEV425 with AGH420
6Pages

{{requestButtons}}

Catalog excerpts

ISOMETER® isoEV425 with AGH420 - 1

ISOMETER® isoEV425 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles

Open the catalog to page 1
ISOMETER® isoEV425 with AGH420 - 2

ISOMETER® isoEV425 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Product description The ISOMETER®s of the isoEV425 series monitor the insulation resistance of unearthed AC/DC main circuits (IT systems) with nominal system voltages of 3(N)AC, AC, AC/DC 0…690 V or DC 0…1000 V. The main application fields are unearthed DC charging stations (mode 4 according to IEC 61851-23) for electric vehicles (IT systems) with nominal system voltages of DC 0…1000 V. Due to a separate supply voltage, de-energised systems can...

Open the catalog to page 2
ISOMETER® isoEV425 with AGH420 - 3

Operating elements 1 - ED "ON" (operation LED) flashes in case of interruption of the L connecting wires E/KE or L1/+ / L2/- or system fault. 2 - larm LED "AL1", lights when the values fall below the set A response value Alarm 1 and flashes in case of interruption of the connecting wires E/KE or L1/+ / L2/-, or system faults as well as in the case of overvoltage (can be activated). 3 - larm LED "AL2" lights when the values fall below the set A response value Alarm 2 and flashes in case of interruption of the connecting wires E/KE or L1/+ / L2/- or system faults as well as in the case of...

Open the catalog to page 3
ISOMETER® isoEV425 with AGH420 - 4

Technical data ISOMETER® isoEV425 Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated voltage (A1, A2) - (11, 14, 24) 300 V Rated impulse voltage 4 kV Overvoltage category III Pollution degree 3 Protective separation (reinforced insulation) between (A1, A2) - (AK1, GND, AK2, Up, KE, T/R, A, B) - (11, 14, 24) Voltage tests according to IEC 61010-1 2.2 kV Interface/protocol RS-485/BMS, Modbus RTU, isoData Baud rate BMS (9.6 kbit/s), Modbus RTU (selectable), isoData (115,2 kbits/s) Cable length (9.6 kbits/s) ≤ 1200 m Cable: twisted pair, one end of shield connected to PE recommended:...

Open the catalog to page 4
ISOMETER® isoEV425 with AGH420 - 5

Technical data coupling device AGH420 Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated insulation voltage 1000 V Rated impulse voltage 8 kV Pollution degree 3 Overvoltage category III Protective separation (reinforced insulation) between (L1/+, L2/-) - (AK1, GND, AK2, Up, E) Voltage test, routine test (IEC 61010-1) 4.3 kV Connection type push-wire terminal Nominal current ≤ 10 A Conductor sizes AWG 24-14 Stripping length 10 mm Connection properties: Rigid/flexible 0.2…2.5 mm² Flexible with ferrule with/without plastic sleeve 0.25…2.5 mm² Multiple conductor flexible with TWIN...

Open the catalog to page 5
ISOMETER® isoEV425 with AGH420 - 6

Example of application TN-C-S system Source Feeder Input Vehicle Cable assembly Connector Vehicle inlet Electric vehicle Isolating transformer IMD Control Pilot Function Note: Only one IMD may be active in each interconnected IT system Control Pilot Function Air condition other consumers = AC on-board charger with electrical separation 14 V on-board power system (electrical separated) Electrical Chassis / Protective equipotential bonding RTyre Bender GmbH & Co. KG P.O. Box 1161 • 35301 Gruenberg • Germany Londorfer Straße 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401...

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages