video corpo

ISOMETER® iso165C
6Pages

{{requestButtons}}

Catalog excerpts

ISOMETER® iso165C - 1

ISOMETER® iso165C… Insulation Monitoring Devices (IMD) for unearthed DC drive systems (IT systems) in electric vehicles

Open the catalog to page 1
ISOMETER® iso165C - 2

Insulation Monitoring Devices (IMD) for unearthed DC drive systems (IT systems) in electric vehicles Product description The ISOMETER® monitors the insulation resistance between the active HV components of an electrical drive system (Un = DC 0 V…600 V) and the reference earth (chassis ground). The patented measurement technology is used to monitor the condition of the insulation on the DC side as well as on the AC motor side of the electrical drive system. The ISOMETER® is assembled with three connectors. To achieve internal galvanic separation, connector 1 is connected to low-voltage (LV)...

Open the catalog to page 2
ISOMETER® iso165C - 3

Function (continued) The initial measurement values after power up are: HV relays open 50,000 kΩ 0V Value in V Insulation resistance Voltage of HV1 Voltage of HV2 HV relays closed Value in kΩ Value in V Value in V The ISOMETER® generates a pulsed measuring voltage that is superimposed on the IT system by terminals T_31_E/KE (chassis). Because the connection between the terminals E/KE and the chassis ground (T_31) is continuously monitored, it is necessary to install two separated conductors from terminals T_31_E/KE to chassis ground. Standards – corresponding norms and regulations General...

Open the catalog to page 3
ISOMETER® iso165C - 4

Connectivity Connector *) Black White Blue lease refer to „Technical Data“ for detailed connector P information. Typical application RESS 1 Electrical Chassis / Protective equipotential bonding Ordering information Nominal voltage Supply voltage Alarm 1 (Error): 30 kΩ…1 MΩ (default: 300 kΩ); Alarm 2 (Warning): 40 kΩ…2 MΩ (default: 55 kΩ) Alarm 1 (Error): 30 kΩ…1 MΩ (default: 400 kΩ); Alarm 2 (Warning): 40 kΩ…2 MΩ (default: 250 kΩ) Response value range Accessories Type

Open the catalog to page 4
ISOMETER® iso165C - 5

Technical data Supply voltage Supply voltage Us Nominal supply voltage Max. operational current IS Max. current IK Power dissipation PS Supervised IT system Rated voltage range Un Tolerance Frequency range System leakage capacitance Ce Withstand voltage test Measuring circuit Protocol iso165C Data rate Terminating resistance iso165C-1 Data rate Terminating resistance HS-CAN 250 kBaud 124 Ω internally 500 kBaud None Environment/EMC EMC Overvoltage category/degree of pollution Temperature range Range of application Measurement method Bender DCP technology Measuring voltage Um ±40 V Measuring...

Open the catalog to page 5
ISOMETER® iso165C - 6

Dimension diagram Dimensions in mm ±2 most acceptable eveness of body interface 4x 0.5 Bender GmbH & Co. KG P.O. Box 1161 • 35301 Gruenberg • Germany Londorfer Strasse 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-Mail: info@bender.de • www.bender.de BENDER Group iso165Cx_D00154_04_D_XXEN / 03.2021 / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 03.2021 unless otherwise ind

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages