Isolated Power Systems Equipment
16Pages

{{requestButtons}}

Catalog excerpts

Isolated Power Systems Equipment - 1

Isolated Power Systems Equipment For healthcare facilities and critical care areas

Open the catalog to page 1
Isolated Power Systems Equipment - 3

PROTECT PATIENTS AND STAFF With isolated power solutions from the leader in electrical safety. Standards such as NFPA 99 and CSA Z32 require isolated power systems in all areas deemed “wet procedure locations” in healthcare facilities. Isolated power systems offer an invaluable advantage - early detection of ground faults allows for critical systems to remain online in a single fault condition. Bender isolated power panels provide isolated power to electrical systems in operating rooms and other critical care areas. Utilizing the latest in technology, Bender equipment ensures that...

Open the catalog to page 3
Isolated Power Systems Equipment - 4

Isolated power panels (receptacle add-on shown) Standard features: Single-phase, low-leakage isolation transformer, with primary and secondary voltages configured at factory and rated to system requirements ■ Primary circuit breaker ■ Up to 16 branch circuit breakers (maximum allowed by UL) ■ LIM2010 line isolation monitor, featuring self-calibration, a wide variety of alarms, including total hazard current (THC, configurable for 2 mA or 5 mA), voltage, overload, and more ■ Reference ground bus Integratable options: ■ Built-in power receptacles and ground jacks ■ Onboard ground fault...

Open the catalog to page 4
Isolated Power Systems Equipment - 5

Features: Single-phase, low-leakage isolation transformer, with primary and secondary voltages configured at factory and rated to system requirements ■ Primary circuit breaker ■ Up to 16 branch circuit breakers (maximum allowed by UL) ■ LIM2010 line isolation monitor, featuring self-calibration, a wide variety of alarms, including total hazard current (THC, configurable for 2 mA or 5 mA), voltage, overload, and more ■ Reference ground bus ■ Configured for x-ray and laser equipment at intervals up to 60 A (panel power rating permitting), up to 16 circuits ■ PLC-controlled receptacle control...

Open the catalog to page 5
Isolated Power Systems Equipment - 6

Dual voltage Isolated power panelsDual system isolated power panels Features: Single-phase, low-leakage isolation transformer, with primary and secondary voltages configured at factory and rated to system requirements ■ Primary circuit breaker ■ Up to 16 branch circuit breakers (maximum allowed by UL) ■ One secondary main circuit breaker for high voltage side ■ LIM2010 line isolation monitor, featuring self-calibration, a wide variety of alarms, including total hazard current (THC, configurable for 2 mA or 5 mA), voltage, overload, and more ■ Two reference ground buses ■ Section for...

Open the catalog to page 6
Isolated Power Systems Equipment - 7

Features: ■ No interference with electrical equipment ■ Works on both 50 Hz and 60 Hz systems (100 -240 VAC) ■ Total hazard current (THC) adjustable, 2 mA / 5 mA per local requirements ■ Additional alarms including transformer overload and overtemperature, overvoltage and undervoltage, ground connection, and more ■ Measures both system resistance and impedance ■ Audible and visual alarm indication Two programmable voltage-free SPDT contacts LIM2010 line isolation monitor ■ Colored bar graph display Automatic self-calibration and self-check Supported accessories: ■ UL 1022 listed (standard...

Open the catalog to page 7
Isolated Power Systems Equipment - 8

J LIM2010 line isolation monitor • Controls line isolation monitoring, main load monitoring, and fault location 2| Ground fault location and branch load modules • EDS441: Automated branch ground fault location • CMS460: Individual branch load monitoring 3| Remote indicators / remote indicating stations • MK2000 series: Provides status for a single isolated power system, options for remote test • MK2430 / MK800 series: Provides status for multiple isolated power systems with customizable messages ^ Communication gateways • COM465IP: Simple, modern GUI interface for remote panel status,...

Open the catalog to page 8
Isolated Power Systems Equipment - 9

Locate ground faults automatically with the EDS441 built into isolated power panels Fast, automated location of ground faults while the system remains online ■ Reduce time and maintenance costs with fast fault location ■ Indication of faulty circuit shown on EDS441, connected remotes, and communication gateways ■ Available integrated into panel, or available separately to retrofit intto existing panels ■ Modular design allows for individual ratings specifications per branch / channel ■ Current transformers integratable into panel as option - simple landing terminals for easy installation ■...

Open the catalog to page 9
Isolated Power Systems Equipment - 10

Features: Centralized remote station for Bender equipment ■ Full-featured remote indicating station for operating status, warnings, and customized alarm messages ■ Compatible with both LIM2010 line isolation monitor and EDS fault location systems ■ Connects to Bender equipment via RS-485 ■ Works with up to 150 Bender devices ■ LCD display Up to 200 customizable alarm messages ■ Memory with real-time clock to store up to 250 timestamped alarm messages ■ Configurable with PC software ■ Flush and surface mounted models Options: ■ Sixteen (16) digital inputs ■ Pre-built assembly wih stainless...

Open the catalog to page 10
Isolated Power Systems Equipment - 11

Features: Visual and audible indication of line isolation monitor (LIM) status ■ Green SAFE LED and red HAZARD LED ■ Audible alarm with mute button and amber LED ■ LED display for long life ■ Uses low voltage 12 V wiring ■ Mounts to standard electrical gang box ■ Easy-to-clean Lexan front foil Amber LED for transformer overload Remote test button ■ Digital display showing total hazard curernt (THC) in real-time ■ Digital display showing transformer load percentage in real-time Features: ■ Visual and audible indication of line isolation monitor (LIM) status ■ Green SAFE LED and red HAZARD...

Open the catalog to page 11
Isolated Power Systems Equipment - 12

Supported equipment and accessories: ■ W-8000 series current tranformers LIM2010 line isolation monitor ■ MK2430 / MK800 series remote indicating stations ■ Remote communication gateways Features: Quickly and automatically locate ground faults in the corresponding branch while the system remains online ■ Works with LIM2010 line isolation monitor ■ Up to 12 branches monitored in parallel by one module ■ Connects to external current transformers for measurement ■ Connects to Bender equipment via RS-485 ■ Works with Bender remote indicating stations and communication gateways ■ Integratable...

Open the catalog to page 12

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages