video corpo

ESL0107 transformers for operating theatre lights
4Pages

{{requestButtons}}

Catalog excerpts

ESL0107 transformers for operating theatre lights - 1

for operating theatre lights Single-phase isolating transformers for the supply of operating theatre lights

Open the catalog to page 1
ESL0107 transformers for operating theatre lights - 2

Single-phase isolating transformers for the supply of operating theatre lights ESL0107 transformers for operating theatre lights Application and description The transformers of the ESL0107 series have reinforced insulation and comply with the requirements of IEC 61558-2 -6 / DIN EN 61558-2-6 (VDE 0570-1). The transformers are fitted with tapping points for fine-step voltage adaptation on the primary and secondary side and thus meet the requirements for power supplies of operating theatre luminaires in Group 2 rooms. The windings are galvanically isolated. In order to minimize electrical...

Open the catalog to page 2
ESL0107 transformers for operating theatre lights - 3

Technical data Type Insulation classification Degree of protection/protection class Power/voltages/currents Rated power Rated frequency Rated input voltage Rated input current Rated output voltage Rated output current Inrush current IE Leakage current No-load input current i0 No-load output voltage u0 Short-circuit voltage uk Recommended fuse when used in accordance with DIN VDE 0100-710 6 A gL/gG Induction 1.23 T Rprimary 15.3 Ω Rsecondary 0.32 Ω FE loss (iron loss) 5.5 W Cu loss (copper loss) 15.8 W Efficiency 85 % Environmental conditions Ambient temperature No-load temperature rise...

Open the catalog to page 3
ESL0107 transformers for operating theatre lights - 4

Isolating transformer enclosure ESL0107-0 Sheet-steel enclosure for wall mounting for operating theatre luminaires transformers ESL0107/120 to ESL0107/1000. Enclosure • heet steel, varnished in RAL 7032 S • egree of protection IP 23 D • ore holes for cable entry B • ransformers of the sizes 120 bis 1000 VA are already provided with fixing holes and can easily be retrofitted to other systems at any time. T Ordering information enclosure Bender GmbH & Co. KG P.O. Box 1161 • 35301 Grünberg • Germany Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259...

Open the catalog to page 4

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages