Changeover and monitoring module UFA710-2-…

Open the catalog to page 1
Changeover and monitoring moduleUFA710-2-... - 2

Changeover and monitoring module UFA710-2-… for medical IT systems with an insulation fault locator Device features • Continuous monitoring of the internal electronics and the circuitry with automatic alarm • Preventive safety due to an automatic reminder of mandatory testing procedures • Maximum reliability when switching – Patented switching system with mechanical and electrical interlocking – Weld-resistant contacts with the mechanics of a circuit breaker – nsensitive to voltage fluctuations and vibrations due to stable I switching position and permanent contact pressure Tasks The...

Open the catalog to page 2
Changeover and monitoring moduleUFA710-2-... - 3

Changeover and monitoring module UFA710-2-… Other safety-enhancing measures • Continuous monitoring of all essential components and connecting wires for proper functioning • Monitoring for short-circuits at the output of the transfer switching device with defined switching behaviour • Maximum reliability when switching with: – patented switching system with mechanical and electrical A interlocking – eld-resistant contacts with the mechanics of a circuit breaker W – nsensitive to voltage fluctuations and vibrations due to stable I switching position and permanent contact pressure •...

Open the catalog to page 3
Changeover and monitoring moduleUFA710-2-... - 4

Changeover and monitoring module UFA710-2-… Bypass switch Clear text display of messages On the UFA710-2-…-BP changeover and monitoring module, uninterrupted testing or repair of the ATICS® transfer switching and monitoring device can be carried out by means of the bypass switch. Please read the instructions for operation of the bypass switch in the manual. Operating, warning and fault messages are indicated by means of clear text display. The required alarm indicator and test combination MK2430, MK800 or the remote alarm indicator and operator panel TM800 must be installed in a place in...

Open the catalog to page 4
Changeover and monitoring moduleUFA710-2-... - 5

Changeover and monitoring module UFA710-2-… Technical data Insulation coordination acc. to IEC 60664-1 *) ATICS digital input *) Rated insulation voltage Rated impulse withstand voltage/pollution degree Nominal insulation voltage Voltage ranges *) Nominal system voltage Un Nominal frequency fn Supply voltage US Frequency range of Us Current consumption during the changeover process ATICS alarm output *) AC 230 V 50…60 Hz from the system being monitored 50…60 Hz 17 A/< 30 ms Power section/switching elements *) Rated operational voltage Ue Frequency of Ue Rated operational current Ie Crest...

Open the catalog to page 5
Changeover and monitoring moduleUFA710-2-... - 6

Ordering details Number of outgoing circuits B16A * Permissible back-up fuse max. * Other circuit breakers on request All UFA modules listed in the table can also be purchased as 400 V version with the same ordering details with the additional marking “-400” Dimensions and weights Type UFA710-2-…-06-B16 UFA710-2-…-12-B16 UFA710-2-…-18-B16 UFA710-2-…-24-B16 UFA710-2-…-BP-06-B16 UFA710-2-…-BP-12-B16 UFA710-2-…-BP-18-B16 UFA710-2-…-BP-24-B16 Recommended cabinet depth mm One row has a height of 150 mm. One section has a width of 250 mm. All UFA modules listed in the table can also be purchased...

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages