Catalog excerpts
CC613 charge controller Charge controller for use in electric vehicle charging stations, wallboxes or street light charging points
Open the catalog to page 1Charge controller for use in electric vehicle charging stations, wallboxes or street light charging points Device features • Charge controller in accordance with IEC 61851-1 (mode 3 charging) • Master and slave operation configurable – Setting up charging stations with two charging points: 1 charge controller as data gateway with 4G modem and 1 charge controller as slave without 4G modem • Dynamic load management to optimally distribute the available power among all charging points and signal the maximum power to the vehicle • Residual direct current monitoring module (external RCD type A...
Open the catalog to page 2Functional description The charging system consists of an RCD type A and a contactor. These are directly connected to a type 1 or type 2 socket-outlet, or to an attached cable with a type 1 or type 2 plug. General functions • The charging system can be equipped with a meter. For digital meter readings, a Modbus meter is required. The Modbus RTU wires are attached directly to the charge controller. • A 12 V power supply is needed for operation. • An RFID module can be used for easy user interaction. • Power flow toward the vehicle is enabled by enabling the contactor via an integrated 230 V...
Open the catalog to page 3Charging system with type 2 socket-outlet N L3 A Connection measuring current transformer (CT) B 12 V supply, PE, Modbus meter, CP, PP G Micro SIM card slot (only available for variants with 4G modem1) H Weld check, relay for contactor control rated for 230 V/4 A I External Modbus (galvanic separation) Input 0 V Supply voltage +12 V Input PE Input PE Modbus meter B Modbus meter A Control Pilot Proximity Pilot Weld check input L1 Relais 23: Switching contact contactor Weld check input N Relais 24: Switching contact contactor External Modbus GND (shield connected on one side) External Modbus...
Open the catalog to page 4Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Proximity Pilot (terminal B (PP)) Rated voltage Overvoltage category Overvoltage category Rated impulse voltage Rated impulse voltage Double insulation acc. to OVC III between Basic insulation acc. to OVC II Operating altitude 250 V II (within terminal H) III (terminal H and all other terminals) 6 kV (terminal H and all other terminals) 2.5 kV (within terminal H) terminal H and all other terminals within terminal H ≤ 2000 m AMSL Supply voltage (terminal B (0V, +12V)) Nominal voltage Operating range of the nominal voltage...
Open the catalog to page 5Technical data Connection type (terminal block H) Connection specifications: rigid /flexible flexible with ferrule without plastic sleeve flexible with ferrule with plastic sleeve Stripping length Max. connection cable length Cross-section Other Operating mode Mounting position Degree of protection DIN rail Weight continuous operation front panel orientated, air must pass through cooling slots vertically IP20 IEC 60715 max. 500 g (depends on variant) Ordering information RDC-M User interface External Modbus – – Powerline Communication acc. ISO/IEC 15118 The charge controller with residual...
Open the catalog to page 6All BENDER catalogs and technical brochures
-
ISOMETER® IR155-4210
6 Pages
-
ISOMETER® IR155-3210
6 Pages
-
CTBC17
2 Pages
-
CC612 EV charge controller
6 Pages
-
Coupling device AGH150xx
4 Pages
-
IOM441-S / IOM441W-S
4 Pages
-
LINETRAXX® CTUB100-Serie
10 Pages
-
LINETRAXX® CTAC-Serie
6 Pages
-
ATICS®-...-DIO
6 Pages
-
COMTRAXX® COM465ID
8 Pages
-
COMTRAXX® COM465DP
8 Pages
-
COMTRAXX® COM465IP
8 Pages
-
COMTRAXX® CP9...-I Serie
6 Pages
-
POWERSCOUT®
8 Pages
-
LINETRAXX® CMD420/CMD421
6 Pages
-
LINETRAXX® VMD460-NA
8 Pages
-
LINETRAXX® VMD420
6 Pages
-
LINETRAXX® VME421H
6 Pages
-
LINETRAXX® VME420
6 Pages
-
Energy meter
6 Pages
-
NGRM700 (HRG)NGRM750 (LRG)
12 Pages
-
NGRM500 (HRG)NGRM550 (LRG)
10 Pages
-
RDC121
7 Pages
-
RCMB123
7 Pages
-
RCMB 121-2
7 Pages
-
RCMB121-1
7 Pages
-
LINETRAXX® MRCDB423
6 Pages
-
RDC104-4
6 Pages
-
LINETRAXX® RCMB330
4 Pages
-
LINETRAXX® RCMB300-Serie
12 Pages
-
Serie LINETRAXX® MRCDB300
12 Pages
-
LINETRAXX® RCMB42...
6 Pages
-
LINETRAXX® RCMS150 series
6 Pages
-
ISOSCAN® EDS440/441
12 Pages
-
ISOMETER® iso165C
6 Pages
-
ISOMETER® isoCHA425
6 Pages
-
ISOMETER® isoGEN423
6 Pages
-
ISOMETER® isoPV1685...
6 Pages
-
ISOMETER® isoMED427x-(PT)
6 Pages
-
ISOMETER® iso415R
4 Pages
-
ISOMETER® isoHR685W-x-I-B
10 Pages
-
ISOMETER® isoRW685W-D-B
8 Pages
-
ISOMETER® isoRW685W-D
8 Pages
-
ISOMETER® isoNAV685-D-B
8 Pages
-
ISOMETER® isoNAV685-D
8 Pages
-
ISOMETER® iso685-...-P
10 Pages
-
ISOMETER® iso685-...-B
8 Pages
-
ISOMETER® iso685
8 Pages
-
Isolated Power Systems Equipment
16 Pages
-
The Power in Electrical Safety
404 Pages
-
Coupling device AGH676S-4
4 Pages
-
Bender Remote Assist
8 Pages
-
300ST
4 Pages
-
400ST
4 Pages
-
UNIMET® 810ST
4 Pages
-
ISOSCAN® EDS460-DG
8 Pages
-
ISOSCAN® EDS460-D/EDS461-D
10 Pages
-
ISOMETER® IRDH575
8 Pages
-
ISOMETER® isoRW425
6 Pages
-
ISOMETER® IR123P
4 Pages
-
ISOMETER® IR423
6 Pages
-
ISOMETER® isoMED427P
6 Pages
-
ISOMETER® IR1575
6 Pages
-
ISOMETER® IR425-D4
6 Pages
-
ISOMETER® IR420-D4
6 Pages
-
TCP - Touch Control Panel
4 Pages
-
Series AT-Display panels
6 Pages
-
COMTRAXX® MK2430
6 Pages
-
ATICS®-…-DIO
4 Pages
-
ATICS®-…-ISO
6 Pages
-
UMA710-2-xx-ISO, ...-BP
44 Pages
-
USC710D4
6 Pages
-
Isolating transformer ES710
8 Pages
-
Isolating transformer DS0107
6 Pages
-
DI-1DL
4 Pages
-
DI-2
4 Pages