video corpo

ATICS®-...-DIO
6Pages

{{requestButtons}}

Catalog excerpts

ATICS®-...-DIO - 1

ATICS®-…-DIO Automatic switching device for safety power supplies

Open the catalog to page 1
ATICS®-...-DIO - 2

Automatic switching devices for safety power supplies Task Where sensitive electrical installations are involved, e.g. in medical locations of Group 2, industry or computing centre, safe and reliable power supply must be ensured, also in the event of malfunctions. Redundant supply lines significantly contribute to achieve safe and secure power supply. Product description Device features Perfectly suitable for space-saving installation/retrofitting • ompact device for designing safety power C supplies with functional safety more easily, in accordance with DIN VDE 61508 (SIL 2), in computing...

Open the catalog to page 2
ATICS®-...-DIO - 3

ATICS®-DIO automatic switching devices Standards The transfer switching device conforms to the following standards: Standard-compliant isolating transformer monitoring according to: The standards marked with * were part of the test conducted by TÜV Süd. • IEC 60364-7-710:2002-11* • IEC 60364-7-710:2021-05 • DIN EN 61508-1 (VDE 0803-1):2011-02* • IEC 61508-1 (2010-04) Ed. 2.0* • DIN EN 61508-2 (VDE 0803-2):2011-02* • IEC 61508-2 (2010-04) Ed. 2.0* • DIN EN 61508-3 (VDE 0803-3):2011-02* • IEC 61508-3 (2010-04) Ed. 2.0* • DIN EN 60947-6-1 (VDE 0660-114):2014-09 • IEC 60947-6-1 (2013-12) Ed....

Open the catalog to page 3
ATICS®-...-DIO - 4

ATICS®-DIO automatic switching devices Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Overvoltage category III Pollution degree outside, inside 2 Rated insulation voltage ATICS-2-DIO/ATICS-4-DIO 250 V/400 V Protective separation between Line 1 – Line 2; Line 1, 2, 3 – RS-485 Line 1, 2, 3 – digital inputs; Line 1, 2, 3 – relay outputs Voltage test according to IEC 61010-1 (basic insulation/protective separation) 2.21 kV/3.54 kV Supply voltage Rated operational voltage Ue Supply voltage US Power consumption ATICS-2-63A-DIO Power consumption ATICS-2-80A-DIO Power...

Open the catalog to page 4
ATICS®-...-DIO - 5

ATICS®-DIO automatic switching devices Technical data Dimension diagram Power section Connection directly on ATICS®, for plug connections and connection of 160 A version screw-type terminals rigid (flexible)/conductor sizes 10…95 mm² (6…70 mm²)/8 (10)…000 (00) AWG Stripping length 15 mm Tightening torque (hexagon socket 4 mm) 5 Nm Connection type (up to 125 A) pluggable screw terminals Conductor cross section, rigid min./max 1.5/35 mm² Conductor cross section, flexible min./max. 1.5/25 mm² Conductor cross section AWG/min./max 16/2 Stripping length (without ferrules) 20 mm Tightening torque...

Open the catalog to page 5
ATICS®-...-DIO - 6

Ordering information ATICS®…-DIO 2-pole Version 2-pole Bypass switch set Rated operational current Ie 1 x STW3, bridge, connectors, terminal cover 1 x STW3, bridge, connectors, terminal cover Bridge, terminal cover, auxiliary contacts, LEDs green/red Bridge, terminal cover, auxiliary contacts, LEDs green/red Rated operational current Ie 4 x STW3, bridge, connectors, terminal cover 4 x STW4, bridge, connectors, terminal cover 4 x STW4, bridge, terminal cover Bridge, terminal cover, auxiliary contacts, LEDs green/red Bridge, terminal cover, auxiliary contacts, LEDs green/red Bridge, terminal...

Open the catalog to page 6

All BENDER catalogs and technical brochures

  1. CTBC17

    2 Pages

  2. POWERSCOUT®

    8 Pages

  3. Energy meter

    6 Pages

  4. RDC121

    7 Pages

  5. RCMB123

    7 Pages

  6. RCMB 121-2

    7 Pages

  7. RCMB121-1

    7 Pages

  8. RDC104-4

    6 Pages

  9. 300ST

    4 Pages

  10. 400ST

    4 Pages

  11. USC710D4

    6 Pages

  12. DI-1DL

    4 Pages

  13. DI-2

    4 Pages