Product Description
The W0-S20…W5-S210 series measuring current transformers are designed to convert residual currents up to 100 A into RCM or EDS signals. They connect to evaluators via two wires, with a maximum distance of 40 m depending on the connecting lead. It is crucial that all current-carrying conductors pass through the CT without shielding, and PE conductors should never be routed through the transformer.

Typical Applications
  • Residual current monitors (RCM)
  • Residual current monitoring systems (RCMS)
  • Insulation fault locators with additional EDS in AC and DC systems

Standards and Approvals
The transformers comply with IEC 61869-1 standards. Various models have different approvals, such as UL and EAC.

Technical Data
  • Insulation coordination: IEC 60044-1
  • Highest system voltage: AC 720 V
  • Rated transformation ratio: 600/1
  • Rated burden: 180 Ω
  • Accuracy class: 3
  • Operating temperature: -10 to +50 °C
  • Degree of protection: IP40 (internal), IP20 (terminals)

Installation Instructions
  • Do not pass shielded cables through the transformer.
  • Ensure all current-carrying leads pass through the transformer in the correct direction.
  • Maintain specified minimum bending radius for primary conductors.

Dimensions and Weight
Various models have different dimensions and weights, ranging from 85 g for W10/600 to 2500 g for W5-S210.

Connection Details
  • Connection via screw-type terminals.
  • Conductor sizes range from 0.2 to 4 mm².
  • Recommended shielded cable: J-Y(St)Y min. 2 x 0.6.

Environmental and Mechanical Specifications
  • Shock resistance: 15 g/11 ms
  • Vibration resistance: 1 g/10…150 Hz
  • Climatic class: 3K22

Ordering Information
Details on ordering and EU Declaration of Conformity are available via a QR code.
See more

Catalog excerpts

W0-S20…W5-S210 W10/600-1

W0-S20…W5-S210 W10/600 Measuring current transformers

 Open the catalog to page 1
W0-S20…W5-S210 W10/600-2

Measuring current transformers Product description The highly sensitive W0-S20...W5-S210 series measuring current transformers convert residual currents up to 100 A into evaluable RCM or EDS signals. The CTs are connected to the respective evaluator by two wires. Depending on the connecting lead used, the distance between the CT and the evaluator may be up to 40 m. Care should be taken that all current-carrying conductors are passed through the CT and that these conductors are not shielded. Never route a PE conductor through the measuring current transformer! Typical applications • For residual...

 Open the catalog to page 2
W0-S20…W5-S210 W10/600-3

Dimension diagrams Type W10/600 Measuring current transformers W0-S20...W5-S210 / W10/600

 Open the catalog to page 3
W0-S20…W5-S210 W10/600-4

Technical data Installation instructions • D o not pass shielded cables through the measuring current transformer. Highest system voltage for electrical equipment Um Rated impulse withstand voltage Uisol Measuring circuit Rated transformation ratio Rated burden Phase displacement Rated primary current Rated primary current Nominal power Rated frequency Internal resistance Secondary overvoltage protection Accuracy class Rated continuous thermal current Rated short-time thermal current Rated dynamic current 600/1 180 Ω (18 Ω at 100 A) <4° ≤10 A (100 A) ≥10 mA 50 mVA 15…400 Hz 5…8 Ω with suppressor...

 Open the catalog to page 4

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.