UMA710-2-xx-DIO, …-BP-1

Changeover and monitoring module UMA710-2-xx-DIO, …-BP

 Open the catalog to page 1
UMA710-2-xx-DIO, …-BP-2

Changeover and monitoring module UMA710-2-xx-DIO, ...BPApplication Device features • Automatic transfer switching device ATICS® for monitoring (amongst others): - voltage of the incoming supplies - output voltage - correct switch position - switching times • Uninterrupted testing and replacement when a bypass switch is included (bypass is recommended) • Variable changeover period t < 0.5.15 s • Information exchange via bus technology • Connection for alarm indicator and operator panels TM800/MK800/MK2430 • Short delivery times • Time-efficient and cost-effective due to ready-to-connect distribution...

 Open the catalog to page 2
UMA710-2-xx-DIO, …-BP-3

Changeover and monitoring module UMA710-2-xx-DIO The changeover is controlled by the ATICS® device. If the preferred supply fails, the ATICS® ensures that the power supply is changed over safely. The switch contacts are offset on a rotating shaft. This design prevents simultaneous switching on of line 1 and line 2. The switch has three positions: • 0 - Both lines are switched off In the normal condition (fault-free operation) the preferred supply is connected. The ATICS® will switch to the redundant line if: • The preferred line fails • The "TEST" button is pressed and the test function is executed...

 Open the catalog to page 3
UMA710-2-xx-DIO, …-BP-4

Changeover and monitoring module UMA710-2-xx-DIO Z BENDER Wiring diagram UMA710-2-xx-DIO-BP (example illustration) Outgoing line 1 - Alarm indicator and test combination MK...(firmware 4.01 or 2 - Remove terminating resistor if other bus devices are to be connected here 4 - Digital inputs (3 inputs programmable, 1 for bypass) 5 - Alarm contacts (3x N/O contacts, 1x changeover contact) 6 - Preferred line (line 1) AC 230 V, 50 Hz 7 - Redundant line (line 2) AC 230 V, 50 Hz The image shows an example of a typical wiring diagram (black box). Please observe the individual, job-related or project-related...

 Open the catalog to page 4
UMA710-2-xx-DIO, …-BP-5

Changeover and monitoring module UMA710-2-xx-DIO Technical data graphic display 500 data records 500 data records/channel 300 data records 100 data records 100 data records Rated operational voltage Ue 230 V Power section/switching elements Nominal system voltage Un AC 230 V (AC 160.. .276 V) (operating range) Displays and data memory Display (languages DE, EN,FR) History memory Data logger Config. logger Test logger Service logger Function adjustable: function test, switching back interlocking function, manual/automatic mode, bypass operation, changeover of the preferred line, alarm input for...

 Open the catalog to page 5
UMA710-2-xx-DIO, …-BP-6

BENDER Group UMA710-2-xx-DIO_D00190_01_D_XXEN / 01.2019 / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 01.2019 unless otherwise indicated. Bender GmbH & Co. KG P.O.Box 1161 • 35301 Gruenberg • Germany Londorfer Straße 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-mail: [email protected]

 Open the catalog to page 6

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.