1. Catalogs
  2. BENDER GmbH & Co KG
  3. UMA710-2-xx-DIO, …-BP

UMA710-2-xx-DIO, …-BP

UMA710-2-xx-DIO, …-BP

UMA710-2-xx-DIO, …-BP

Product catalog summary
Device Features
The UMA710-2-xx-DIO is an automatic transfer switching device (ATICS®) designed for monitoring voltage, switch positions, and functional safety according to IEC 61508 (SIL2). It supports uninterrupted testing and replacement with a bypass switch, has a variable changeover period of t ≤ 0.5…15 s, and facilitates information exchange via bus technology. The device is designed for quick installation with screwless connections and complies with standard design requirements. An optional TÜV test is in preparation.

Application
The UMA710 series modules are used for switching between two power supply sources in safety-critical environments, such as medical locations. They provide alarm and status messages via bus technology and can be mounted on standard equipment racks.

Tasks
The module performs two-pole changeover of power supply, voltage monitoring on both preferred and redundant supplies, and output monitoring. It ensures correct switch positioning and performs internal functional tests. It communicates with remote alarm indicators and operator panels via BMS bus and adheres to DIN VDE 0100-710 standards for changeover periods.

Functions
The device monitors voltage with adjustable control functions, offers protection against incorrect operation, and ensures cables resist short circuits and earth faults. It supports automatic switching back on voltage recovery and includes functional tests for insulation, load current, and temperature monitoring.

Safety Measures
The module continuously monitors essential components and connections, ensuring maximum reliability with patented switching systems and weld-resistant contacts. It includes preventive safety features like automatic reminders for testing procedures and service times.

Functional Description
The ATICS® device controls the changeover process, ensuring safe switching between power lines. It has three switch positions: Line 1 on, both lines off, and Line 2 on. The device switches to the redundant line if the preferred line fails and back when the preferred line is restored.

Bypass Switch
The UMA710-2xx-DIO-BP module allows uninterrupted testing or replacement of the ATICS® device using a bypass switch.

Wiring Diagram
The document includes a typical wiring diagram for the UMA710-2-xx-DIO-BP, illustrating connections for alarm indicators, digital inputs, and power lines.

Technical Data
The module operates at a nominal system voltage of AC 230 V, with a frequency range of 48…62 Hz. It features a graphic display, history memory, and data logger capabilities. The device supports RS-485/BMS interface and operates within a temperature range of -10 °C to +55 °C.

Ordering Information
The document provides dimensions, recommended cabinet depth, and weight for different module types, along with ordering information and contact details for Bender GmbH & Co. KG.
See more

Catalog excerpts

UMA710-2-xx-DIO, …-BP-1

Changeover and monitoring module UMA710-2-xx-DIO, …-BP

 Open the catalog to page 1
UMA710-2-xx-DIO, …-BP-2

Changeover and monitoring module UMA710-2-xx-DIO, ...BPApplication Device features • Automatic transfer switching device ATICS® for monitoring (amongst others): - voltage of the incoming supplies - output voltage - correct switch position - switching times • Uninterrupted testing and replacement when a bypass switch is included (bypass is recommended) • Variable changeover period t < 0.5.15 s • Information exchange via bus technology • Connection for alarm indicator and operator panels TM800/MK800/MK2430 • Short delivery times • Time-efficient and cost-effective due to ready-to-connect distribution...

 Open the catalog to page 2
UMA710-2-xx-DIO, …-BP-3

Changeover and monitoring module UMA710-2-xx-DIO The changeover is controlled by the ATICS® device. If the preferred supply fails, the ATICS® ensures that the power supply is changed over safely. The switch contacts are offset on a rotating shaft. This design prevents simultaneous switching on of line 1 and line 2. The switch has three positions: • 0 - Both lines are switched off In the normal condition (fault-free operation) the preferred supply is connected. The ATICS® will switch to the redundant line if: • The preferred line fails • The "TEST" button is pressed and the test function is executed...

 Open the catalog to page 3
UMA710-2-xx-DIO, …-BP-4

Changeover and monitoring module UMA710-2-xx-DIO Z BENDER Wiring diagram UMA710-2-xx-DIO-BP (example illustration) Outgoing line 1 - Alarm indicator and test combination MK...(firmware 4.01 or 2 - Remove terminating resistor if other bus devices are to be connected here 4 - Digital inputs (3 inputs programmable, 1 for bypass) 5 - Alarm contacts (3x N/O contacts, 1x changeover contact) 6 - Preferred line (line 1) AC 230 V, 50 Hz 7 - Redundant line (line 2) AC 230 V, 50 Hz The image shows an example of a typical wiring diagram (black box). Please observe the individual, job-related or project-related...

 Open the catalog to page 4
UMA710-2-xx-DIO, …-BP-5

Changeover and monitoring module UMA710-2-xx-DIO Technical data graphic display 500 data records 500 data records/channel 300 data records 100 data records 100 data records Rated operational voltage Ue 230 V Power section/switching elements Nominal system voltage Un AC 230 V (AC 160.. .276 V) (operating range) Displays and data memory Display (languages DE, EN,FR) History memory Data logger Config. logger Test logger Service logger Function adjustable: function test, switching back interlocking function, manual/automatic mode, bypass operation, changeover of the preferred line, alarm input for...

 Open the catalog to page 5
UMA710-2-xx-DIO, …-BP-6

BENDER Group UMA710-2-xx-DIO_D00190_01_D_XXEN / 01.2019 / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 01.2019 unless otherwise indicated. Bender GmbH & Co. KG P.O.Box 1161 • 35301 Gruenberg • Germany Londorfer Straße 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-mail: [email protected] •

 Open the catalog to page 6

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.