RDC121-1

Customer: Standard type • Fluxgate current sensor with toroidal core • Excellent accuracy • AEC-Q qualified components • Switching open-collector outputs • Compact design Mainly used for stationary and mobile applications: Electrical data - Ratings Ip Primary nominal RMS current (1phase / 3phase) 80 / 40 A (3) Switching time of a standard relay (t = 20ms) is considered. (4) see VAC M-sheet 3101; storage temperature inside cardboard packaging (5) Constructed, manufactured and tested in accordance with IEC60664-1:2007 Isolated wires are preferred to fulfill the insulation coordination acc. to IEC 62955:2018, it is necessary to use insulated primary conductors that meet the requirements of the basic insulation for the rated voltage. If isolated primary conductors are used, the isolation coordination is acc. to: Reinforced insulation, Insulation material group 1, Pollution degree 2 and overvoltage category III. (6) The results are valid under following conditions: 55°C mean component ambient temperature by continuous operation (8760h per year); Environment condition: ground mobile, no dust or harmful substances, according to IEC61709; Fit equals one failure per 10*9 component hours. General description of sensor function: The sensor is sensitive to DC currents and can be used for fault current detection in EV-charging applications according IEC 62955:2018. In the event of a DC fault current, PIN3 and PIN4 will change its state from a low level to a high impedance state. Error conditions (e.g. an internal error) are signaled on PIN 1 (ERROR-OUT). The sensor only fulfills the switch-off characteristic of the IEC62955 standard (monitoring the residual current). An additional driver-circuit must be used for driving RCBO, RCCB or circuit breaker as defined in IEC62955. The sensor's outputs are limited to max. 40V/50mA! Datum Name Index Anderung 11.10.2021 BZ 81 Patents added on sheet 1. CN-21-290 23.09.20 MB 81 Final test: change value of TC1 and TC2; remove LV2. Minor change. Designer: MB Released by: SB Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden. Any offenders are liable to pay all relevant damages

 Open the catalog to page 1
RDC121-2

Customer: Standard type Page 2 of 7 Mechanical outline (mm): General tolerances DIN ISO 2768-c Connections:PIN no. 1-8: 0.46mm x 0.46mm PIN no. 9-12: 0.7mm x 0.7mm benvac 4641-X904 F DC Content of Data-Matrix-Code is: benvac, 4641-X904, F, DC Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden. Any offenders are liable to pay all relevant damages

 Open the catalog to page 2
RDC121-3

Differential Current Sensor for stationary applications acc. to the standard IEC62955 K-No.: 30028 Customer: Standard type Typical application diagram: power contactor driver circuit working voltage to driver , control electronics , control electronics e.g. charge Absolute maximum Ratings(6): Min VCE IC VCC UMAX VTEST-IN, low VTEST-IN, high Collector-Emitter voltage (PINs 1, 3 and 4) Collector current (PINs 1, 3 and 4) Maximum supply voltage (without function) Maximum rated voltage of primary conductors (AC rms) TEST-IN Input Voltage, low level TEST-IN Input Voltage, high level Stresses above...

 Open the catalog to page 3
RDC121-4

Differential Current Sensor for stationary applications acc. to the standard IEC62955 K-No.: 30028 Customer: Standard type Final Tests: (Measurements after temperature balance of the samples at room temperature, SC=significant characteristic) Min. 4.9 Vcc Supply voltage 38.0 Icc Supply current 2.8 TEST-IN (SC) TEST-IN voltage 0 X6-OUT (normal) X6-OUT voltage 0 X30-OUT (normal) X30-OUT voltage 0 ERROR-OUT (normal) ERROR-OUT voltage 4.9 X6-OUT (activated) X6-OUT voltage activated @5V, 1kΩ (pull-up)* 4.9 X30-OUT (activated) X30-OUT voltage activated @5V, 1kΩ (pull-up)* ERROR-OUT 4.9 ERROR-OUT voltage...

 Open the catalog to page 4
RDC121-5

Customer: Standard type Requalification Tests: (replicated every year, Precondition acc. to M3238) Impulse test (1.2gs/50|as waveform) PIN 1-8 vs. insulated primary wire 5 pulse ^ polarity +, 5 pulse ^ polarity -Test voltage, 60s PIN 1-8 vs. insulated primary wire Partial discharge voltage (extinction) PIN 1-8 vs. insulated primary wire Partial discharge voltage (extinction) PIN 1-8 vs. insulated primary wire Temperature of the primary conductor should not exceed 105°C. Vcc during Test-IN function test must be at least 4.8V Fall- and rise-time of Vcc 2...50gs/V If the trip-level Ian1 is accomplished...

 Open the catalog to page 5
RDC121-6

Table 1: Possible output states Editor.: R&D-PD-NPI D Designer: MB Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden. Any offenders are liable to pay all relevant damages

 Open the catalog to page 6
RDC121-7

Customer: Standard type Page 7 of 7 Table 2: Maximum and typical values of break time for residual direct currents Sales and distribution: Type VAC DEMISED Bender GmbH & Co. KG • Londorfer StraBe 65 • 35305 Grunberg • Germany DCIMUCn Tel.: +49 6401 807-0 • [email protected] • www.bender.de eMobility • [email protected] • www.bender.de/loesungen/emobility Editor.: R&D-PD-NPI D Designer: MB Copying of this document, disclosing it to third parties or using the contents there for any purposes without express written authorization by use illegally forbidden. Any offenders are liable to pay all relevant...

 Open the catalog to page 7

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RCMB123

    7  Pages

  34. RDC104-4

    6  Pages

  35. RCMB104

    6  Pages

  36. RCMB300-series

    12  Pages

  37. Energy meter

    6  Pages

  38. PEM353

    8  Pages

  39. DS0107

    6  Pages

  40. ESL0107

    4  Pages

  41. ES710

    8  Pages

  42. AGH520S

    4  Pages

  43. RCM410R

    8  Pages

  44. RCMS410

    10  Pages

  45. RCMS425-D

    10  Pages

  46. EDGE500

    12  Pages

  47. Iso415R

    4  Pages

  48. Iso685-x-B

    12  Pages

  49. Iso685-x-P

    14  Pages

  50. Iso685-x

    12  Pages

  51. Data Centers

    16  Pages

  52. RCMB104

    6  Pages

  53. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.