RCMS425-D-1

LINETRAXX® SmartDetect RCMS425-D Four-channel residual current monitor sensitive to AC, pulsed DC, and smooth DC

 Open the catalog to page 1
RCMS425-D-2

Four-channel residual current monitor sensitive to AC, pulsed DC, and smooth DC Product description The LINETRAXX® SmartDetect RCMS425-D is an AC, pulsed DC, and smooth DC sensitive residual-current monitor for earthed power-supply systems. It measures residual currents between 2 mA and 70 A with direct voltage as well as alternating voltage in a frequency range from 15 Hz to 20 kHz. Corresponding measuring-current transformers (e.g. CTUB100 and CTAC series) must be connected to the residual-current inputs. Individual response values for prewarning and main alarm can be set for each channel,...

 Open the catalog to page 2
RCMS425-D-3

Device features Special features • Four measuring channels for AC, pulsed DC, or AC/DC sensitive measuring • Configurable frequency response • TFT display for convenient operation and configuration • Expansion/retrofit or change of functions in the event of changed monitoring requirements • Simple configuration with Bender Connect App via NFC interface • Customer-specific factory settings possible Residual current measurement • Residual current measurement device (RCM) in accordance with DIN EN 62020-1 (IEC 62020-1) • Four channels for residual current measurement • Every channel can alternatively...

 Open the catalog to page 3
RCMS425-D-4

Function modules The NFC interface can be used to transmit a previously configured device parameter setting directly to the device. This function is available only via the Bender Connect App. You can find this app in the Appstores for iOS and Android. In the Bender Connect app the device first needs to be made known. Then the device-specific setting options are shown so that they can be configured. When the data is transferred, feedback is given whether the parameter configuration has been successful. Parameter settings can be transmitted to the device via the Bender Connect app by holding the...

 Open the catalog to page 4
RCMS425-D-5

AC/DC 100...240 V DC 24 V Back-up fuse for US: 6 A RCMS425-D and all connected CTUB102-CTBCxx devices must be supplied from the same power supply. The measuring current transformers must be connected before operation. Cable lengths to the measuring current transformer: See technical data.

 Open the catalog to page 5
RCMS425-D-6

LINETRAXX® SmartDetect RCMS425-D Kr BENDER Connections overview Technical data Voltage test (routine test) acc. to IEC 61010-1 Supply circuit (IC1) Measuring circuit (IC2) Control circuit (IC3) Control circuit (IC4) Rated voltage Overvoltage category Operating altitude Rated impulse voltage Connection Supply voltage Us Protection class of power supply unit Permissible tolerance Permissible ripple Power consumption Inrush current (< 5 ms) Rated insulation voltage Pollution degree Connection Supply voltage US Tolerance of US Frequency range of US Power consumption Inrush current (< 5 ms) Protective...

 Open the catalog to page 6
RCMS425-D-7

Measuring circuit Burden (internal) Frequency range Measuring range (peak) Measuring range rms Rated residual operating current Type A, Type F Type B, Type B+ Response value main alarm IAn'} Type A, Type F Type B, Type B+ Prewarning Operating uncertainty Relative response uncertainty Fault-memory alarm messages Permissible continuous residual current with single-channel use dual-channel use use of three channels use of four channels Time response Start-up delay t Response delay ton Delay on release toff Operating time tae with 1 x IAn with 5 x IAn Response time tan Recovery time tb Response time...

 Open the catalog to page 7
RCMS425-D-8

LINETRAXX® SmartDetect RCMS425-D Kr BENDER Max. cable length (recommended) 10 m Tolerance with respect to final current/voltage ±20 % External voltage (passive mode) DC 0...US Operating temperature Transport Long-time storage Classification of climatic conditions acc. to IEC 60721 (except condensation and formation of ice) Switching elements Relays Operating principle Maximum permitted voltage Switching capacity Minimum current Electrical endurance, number of cycles Classification of mechanical conditions acc. to IEC 60721 Connections (A1, A2, relays) Terminals Terminal series Connection properties...

 Open the catalog to page 8
RCMS425-D-9

Approvals Standards & certifications Dimension diagrams Dimensions in mm The RCMS425-D device has been developed in accordance with the following standards: - DIN EN IEC 62020-1 - UL508 Licences For a list of the open-source software used see our Homepage. Declaration regarding the radio system EU declaration of conformity Bender GmbH & Co. KG hereby declares that the device covered by the Radio Equipment Directive complies with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address: EU declaration of conformity

 Open the catalog to page 9
RCMS425-D-10

Ordering information © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 06.2025 unless otherwise indicated. RBENDERBender GmbH & Co. KG Londorfer StraGe 65 35305 Grunberg Germany

 Open the catalog to page 10

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. EDGE500

    12  Pages

  47. Iso415R

    4  Pages

  48. Iso685-x-B

    12  Pages

  49. Iso685-x-P

    14  Pages

  50. Iso685-x

    12  Pages

  51. Data Centers

    16  Pages

  52. RCMB104

    6  Pages

  53. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.