RCMB131-01

RCMB131-01

RCMB131-01

Product catalog summary
Product Description: The RCMB131-01 is an AC/DC sensitive residual current monitoring module designed to monitor electrically earthed power supplies up to 300 V and connected loads up to 32 A for leakage and fault currents. It is suitable for installation in distribution equipment like PDUs and outlet boxes, operating with a supply voltage of DC 12-24 V.
Applications: The module is intended for use in PDUs and outlet boxes, with communication capabilities via an RS-485 interface using Modbus RTU.
Functional Description: The module measures both AC and DC residual currents, calculating the RMS value from the DC component and AC component below 2000 Hz. It features continuous monitoring of the internal measuring current transformer connection and provides alarm signaling and response value configuration through the RS-485 interface.
Device Features: Key features include high-resolution leakage and fault current monitoring, suitability for PCB mounting, compact design, and integrated test function. It supports a frequency range of DC to 2 kHz and is designed for nominal loads up to 32 A.
Technical Data: The module adheres to insulation coordination according to IEC 60664-1, with a rated voltage of 300 V and an overvoltage category of III. It operates at altitudes up to 3000 m and has a rated insulation voltage of 320 V. The measuring circuit supports an AC/DC range of ±300 mA, with response values configurable for DC and RMS currents.
Wiring and Connection: The module includes pin assignments for supply voltage, ground, switching outputs, and RS-485 communication. It requires a terminating resistor on the last device in the RS-485 bus chain, with a maximum cable length of 10 m.
Environmental and Mechanical Conditions: The module is designed for continuous operation in ambient temperatures from -25 to +70 °C, with classifications for climatic and mechanical conditions according to IEC standards. It has a protection class of IP 30 and a flammability rating of UL94 V-0.
Additional Information: The module has a service life of 10 years at 40 °C and is documented under number D00358.
See more

Catalog excerpts

RCMB131-01-1

AC/DC sensitive residual current monitoring module for measuring AC and DC currents up to ±100 mA

 Open the catalog to page 1
RCMB131-01-2

RCMB131-01 AC/DC sensitive residual current monitoring module Device features • AC/DC sensitive leakage and fault current monitoring for preventive maintenance • High resolution for implementing equipment leakage current monitoring • Measured value and alarm transmission via Modbus RTU (RS-485) • Compact design for monitoring nominal loads up to In = 32 A • Low load current sensitivity due to fully shielded measuring current transformer • Continuous monitoring of the connection to the measuring current transformer • Integrated test function Product description The AC/DC sensitive residual current...

 Open the catalog to page 2
RCMB131-01-3

Vcc Customer Controller * Terminating resistor 120 Ω must only be set on the last device in the RS-485 bus chain The maximum cable length must be limited to ≤ 10 m. The switching outputs S1 and S2 are for monitoring purposes only and may only be used from a set response differential current set differential response current IΔn ≥ 6mA DC or RMS.

 Open the catalog to page 3
RCMB131-01-4

Technical data Insulation coordination according to IEC 60664-1 Primary circuit monitored primary conductors Secondary circuit All following specifications apply to the insulation between the primary and secondary circuit Rated impulse voltage 4 kV Operating altitude Rated insulation voltage Pollution degree Safe separation (reinforced insulation) Voltage test acc. to IEC 61010-1 between primary and secondary circuit AC 2.2 kV Time response Response time tae (relay switching time of 10 ms considered) for 1 X /in for 2 x /in for 5 x /in Response value assignment Voltage supply Operating range...

 Open the catalog to page 4

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RDC121

    7  Pages

  33. RCMB123

    7  Pages

  34. RDC104-4

    6  Pages

  35. RCMB104

    6  Pages

  36. RCMB300-series

    12  Pages

  37. Energy meter

    6  Pages

  38. PEM353

    8  Pages

  39. DS0107

    6  Pages

  40. ESL0107

    4  Pages

  41. ES710

    8  Pages

  42. AGH520S

    4  Pages

  43. RCM410R

    8  Pages

  44. RCMS410

    10  Pages

  45. RCMS425-D

    10  Pages

  46. EDGE500

    12  Pages

  47. Iso415R

    4  Pages

  48. Iso685-x-B

    12  Pages

  49. Iso685-x-P

    14  Pages

  50. Iso685-x

    12  Pages

  51. Data Centers

    16  Pages

  52. RCMB104

    6  Pages

  53. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.