Transparency for your electrical distribution systems
Open the catalog to page 1Time = money and both are resources that are generally in short supply. Staff shortages, ever stricter conditions and deadlines and the constant need to optimise are the counterparts to this simple equation. Responsible electrically skilled persons experience this more and more. They are specialists, but are perceived as all-rounders and are to a large extent responsible for the smooth functioning of operational processes. According to the motto “Just do this as well", the actual tasks are increasingly being neglected. The solution is to automate routine and recurring mandatory tasks. POWERSCOUT®...
Open the catalog to page 2Reports can be generated from the dashboards. A dashboard can always be sent and saved as a report. There is also an option for managing these reports. In the report management, the publishing intervals as well as the storage in POWERSCOUT® can be set. • Automated report generation • Freely configurable time periods • Storing 250 reports in a history • Sending reports via e-mail • Insulation report, residual current report (German Social Accident Insurance Regulation 3 (DGUV V3)) and ATICS® report Building and system overview The installation/system can be displayed by means of freely configurable...
Open the catalog to page 3POWERSCOUT® features User management • Management of users • Different user rights • Restricted views Data import and export Data access from anywhere Web-based application • You can get started immediately after receiving the login details. Your gateway (COM465, CP9xx) sends the measured values to our data centre in encrypted form. USER HTTPS POST ONE WAY • You will receive automatic updates (security and features). • We take care of the backups. CONSUMER CONSUMER Calculation of key figures POWERSCOUT® collects data and information across locations. This data can be compiled for fault analysis...
Open the catalog to page 4Widgets are graphical components that allow individual adjustment of the content displayed in POWERSCOUT®. The widgets can be displayed in individual sizes and positions on a dashboard. A dashboard can show a time period. The widgets displayed on the dashboard can differ from the set dashboard time and show individual time periods. Graph • Linear and logarithmic representation - Insulation values can be displayed more clearly • Scrolling and zooming with the mouse wheel is possible • Minimum and maximum of the Y axis adjustable • Line colour selection • Adjustable line width Event statistics...
Open the catalog to page 5• Lower and upper limit values flexibly adjustable • Monitoring of measured values Bar graph • Display of cumulative meter values in a bar graph • Grouping of data in ascending order • Aggregation by days, weeks, months, quarters and years Table view • Display of measured values in a table • Minimum, maximum and average values can be displayed • Complete overview of minimum, maximum and average values of several measured values
Open the catalog to page 6Text editor • Description of dashboards • Adding custom images Heat map • Display particularly striking values in an easily recognisable way • Colour inversion to allow insulation faults to be displayed as well • Adjustable limit values Sankey diagram • Graphic representation of quantity flows • Preferably used for energy monitoring • System view freely configurable Measurement statistics • Display of a measured value as statistics • Minimum, maximum and average values can be displayed • Colour differentiation individually adjustable
Open the catalog to page 7The Bender world in a nutshell Bender system world POWERSCOUT® POWERSCOUT® cloud Analysis, history Logging Visualisation COMTRAXX® Condition monitoring Web server to COM465IP BCOM TCP/IP Modbus TCP BCOM CP9xx Gateway, alternative to COM465 Condition monitoring COM465IP Gateway Condition monitoring Power monitoring Third-party devices TCP/IP Modbus TCP BCOM Insulation measurement IT system only direct connection BB bus EDS440 + IOM441 Fault location + relay K+I K+I Residual current RCM transformer type A or B TN/TT system Considerably less effort: https:// • The initial and ongoing project costs...
Open the catalog to page 84 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
12 Pages
10 Pages
10 Pages
6 Pages
6 Pages
12 Pages
12 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
6 Pages
8 Pages
6 Pages
8 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
4 Pages
10 Pages
6 Pages
6 Pages
6 Pages
12 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
7 Pages
8 Pages
12 Pages
10 Pages
6 Pages
10 Pages
6 Pages
6 Pages
6 Pages
10 Pages
8 Pages
6 Pages
6 Pages
6 Pages
8 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
6 Pages
12 Pages
12 Pages
12 Pages
4 Pages
7 Pages
7 Pages
2 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
12 Pages
14 Pages
10 Pages
4 Pages
14 Pages
6 Pages
16 Pages
6 Pages
8 Pages
6 Pages
4 Pages
8 Pages
4 Pages
8 Pages
8 Pages
10 Pages
8 Pages
8 Pages
6 Pages
8 Pages
6 Pages
4 Pages
6 Pages
6 Pages
10 Pages
8 Pages
8 Pages
6 Pages
6 Pages
8 Pages
6 Pages
10 Pages
6 Pages
6 Pages
2 Pages
6 Pages
10 Pages
10 Pages
10 Pages
8 Pages
8 Pages
4 Pages
12 Pages
8 Pages
10 Pages
10 Pages
12 Pages
4 Pages
12 Pages
14 Pages
12 Pages
16 Pages
6 Pages
14 Pages
10 Pages
486 Pages