NGRM500 et NGRM550-1

INFO DATA ground fault

 Open the catalog to page 1
NGRM500 et NGRM550-2

_Efc BENDER Neutral Grounding Resistor Monitor Device features • Determination of Rngr with passive and active measurement methods • Continuous monitoring of the Rngr even if the installation is de-energized; • Alarm or trip on ground fault • Monitoring of the voltage UNGR • Ethernet communication • Language selection (German, English GB and US, Spanish, French) • Test button (internal, external) with/without tripping • FFT analysis of neutral current and voltage • Pulser control for manual ground fault location • Relay outputs for detection of ground faults and resistor faults • Relay output...

 Open the catalog to page 2
NGRM500 et NGRM550-3

active The device generates an active test pulse and measures RNGR even if the installation is de-energised. Should the use of frequency inverters lead to interferences with the RNGR measured value during the active measurement, a filter for active resistance measurement can be added. To this end, 3 pre-defined filters (weak, medium, strong) have been implemented. In addition, the filter parameters can be adapted individually in the setting “Customer-specific”. passive The resistance RNGR is determined when INGR or UNGR exceeds an internal threshold. The device measures the existing current and...

 Open the catalog to page 3
NGRM500 et NGRM550-4

NGR monitor NGRM Kr BENDER Device buttons Display elements 4 - TRIPPED The LED is on when the trip relay has been tripped due to an NGR fault, ground fault or a device error. 5 - NGR FAULT The LED flashes in case of a prewarning: NGR fault detected, NGR fault relay has tripped, trip relay has not tripped yet (Ingr trip elapses). The LED is on when an NGR fault has been detected. Trip relay and NGR-fault relay have tripped. on when power supply is available The LC display shows device and measurement information. The LED is on when there is either a device fault or a connection fault, and when...

 Open the catalog to page 4
NGRM500 et NGRM550-5

Connection: Star connection Circuit breaker L1 Ground fault The “N” connection of the CD-series coupling device should be as close to the transformer star point as possible. Connection: Star connection with pulser Circuit breaker L1 Ground fault The “N” connection of the CD-series coupling device should be as close to the transformer star point as possible. An intermediate relay may be required between the power contactor of the pulser and the digital output X1.

 Open the catalog to page 5
NGRM500 et NGRM550-6

NGR monitor NGRM Kr BENDER If no star point is available, the following circuit can create an artificial neutral. N Connection to star point PE Connection to the protective earth conductor of the installation (PE)

 Open the catalog to page 6
NGRM500 et NGRM550-7

Measuring current transformer connection Depending on the system to be monitored, a suitable measuring current transformer has to be chosen. All common measuring current transformers (50 mA or 5 A on the secondary side) can be used. The following table helps you with the choice: System type Transformation ratio Bender measuring current transformer Measuring range (see CTUB103 manual) 5 A 100:1 10 A 200:1 25 A 500:1 Connecting cable CTAC… / CTAS… Any standard current transformer can be used. Connection of relays (ground-fault, NGR-fault and trip relay) Ground-fault relay NGR-fault relay Trip relay...

 Open the catalog to page 7
NGRM500 et NGRM550-8

Connection to the X1 interface X1: Output Q1…2 Digital 1 (configurable: pulser, NGR method) Analogue output Open Collector: Pulser OUT Open Collector: Device condition (Device health) Output for supply of external relays (+24 V, max. 100 mA) X1: Input I1…3 The input is only detected as “activated” after the contact has been activated for at least 150 ms. This way, short interference pulses are ignored. Active high Connection to Q1, Q2: external relay or PLC. Switch Digital 1, active Reset, passive Test open closed Digital 1, active Reset, passive Test < 150 ms Input I1…3: Potential-free contact...

 Open the catalog to page 8
NGRM500 et NGRM550-9

Technical Data Insulation coordination according to IEC 60664-1/IEC 60664-3/DIN EN 50178 Measuring circuit/Control circuit (IC2) Output circuit 1 (IC3) Rated voltage Overvoltage category Rated impulse voltage IC1/(IC2...5) Rated insulation voltage IC1/(IC2_5) Pollution degree exterior Safe isolation (reinforced insulation) between Voltage tests (routine test) acc. to IEC 61010-1 overvoltage category III, 300 V overvoltage category III, 300 V overvoltage category III, 300 V overvoltage category III, 300 V Nominal measuring current In Maximum continuous current Overload capacity Measurement accuracy...

 Open the catalog to page 9
NGRM500 et NGRM550-10

Analogue output (M+) Operating principle linear Functions INGR, RNGR Current 0…20 mA (≤ 600 Ω), 4…20 mA (≤ 600 Ω), 0…400 μA (≤ 4 kΩ) Voltage 0…10 V (≥ 1 kΩ), 2…10 V (≥ 1 kΩ) Tolerance related to the current/voltage end value ±20 % Ground-fault, NGR, trip relay Switching elements Operating mode Electrical endurance, number of cycles Switching capacity Contact data acc. to IEC 60947-5-1 Rated operational voltage AC Utilisation category Rated operational current AC Rated operational current AC (for UL applications) Rated operational voltage DC Utilisation category Rated operational current DC Minimum...

 Open the catalog to page 10
NGRM500 et NGRM550-11

RBENDER Description 11 All types and ordering informations of this series are available on our website Ordering information Suitable system components

 Open the catalog to page 11
NGRM500 et NGRM550-12

Bender GmbH & Co. KG • Germany Londorfer StraRe 65 • 35305 Grunberg Tel.: +49 6401 807-0 • [email protected] www.bender.de USA, Mexico, Central America • Exton PA, USA 800.356.4266 / 610.383.9200 • [email protected] www.bender.org Canada • Missisauga ON, Canada 800.243.2438 / 905.602.9990 [email protected] • www.bender-ca.com © Bender GmbH & Co. KG, Germany Subject to change! South America • Santiago de Chile The specified standards take into +59 2.2933.4211 • [email protected] account the edition valid until 06.2023 www.bender-latinamerica.com unless otherwise indicated.

 Open the catalog to page 12

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.