MRCDB300 series AC/DC sensitive residual current monitoring module for MRCD applications

 Open the catalog to page 1
MRCDB300 series-2

MRCDB300 Series AC/DC sensitive residual current monitoring module Device features • Structure of a protective device in accordance with IEC 60947-2 Annex M in combination with a circuit breaker providing isolating properties • Monitoring of the connected circuit breaker by means of contact feedback • RS-485 interface with Modbus RTU (reading out measured values/setting parameters) • Integrated switching outputs with two changeover contacts K1 and K2 (galvanically isolated) • Fulfils the protection goals protection of persons, fire protection and plant protection (depending on the variant) •...

 Open the catalog to page 2
MRCDB300 series-3

Variants Electronic modules Type B modular residual current protective device acc. to IEC 60755 for the protection of persons in case of indirect contact, response value 30 mA Type B+ modular residual current protective device acc. to VDE 0664-100 for fire protection, response value 300 mA Modular residual current protective device for plant protection (N/C operation), freely configurable Modular residual current protective device for plant protection (N/O operation), freely configurable Modular residual current protective device type B acc. to IEC 60755 for the protection of persons in case...

 Open the catalog to page 3
MRCDB300 series-4

The following applies to all wiring diagrams: • The use of a type 2 surge protection device (SPD) is mandatory due to possible impulse voltages and in order to comply with normative requirements. • The surge protection device must be connected upstream of the power supply unit on the supply side. • Features of the surge protection device - Nominal discharge current In (8/20 ^s): 20 kA - Two-stage: 1 varistor + 1 spark gap Alternatively, the power supply unit can be connected to a CAT II supply without a surge protection device. The power supply unit must be connected before the switch. Wiring...

 Open the catalog to page 4
MRCDB300 series-5

N/O principle without contact feedback N/O principle with contact feedback Wiring diagram MRCDB30… (N/O principle without contact feedback) Wiring diagram MRCDB30… (N/O principle with contact feedback) 21, 22, 24 = Relay for main alarm = surge protection device 21, 22, 24 = Relay for main alarm = surge protection device We recommend operating the alarm relay K1 according to the N/C principle. This allows detecting and reporting the failure of the supply voltage and the internal power supply unit. For economical installation reasons, alarm relay K2 can be operated according to the N/O principle....

 Open the catalog to page 5
MRCDB300 series-6

The LED indicates the system state by means of colours and lighting/flashing. The changeover contacts of relay outputs K1 and K2 have defined switching positions for each system state.

 Open the catalog to page 6
MRCDB300 series-7

Dimension diagrams

 Open the catalog to page 7
MRCDB300 series-9

Example for the composition of an MRCD module Measuring current transformer: CTBC35 Final MRCD module Installation instructions for measuring current transformers CAUTION Device damage due to high induction currents! High currents can be induced into the conductor loop due to the AC/DC sensitive measurement technology used. Do not route protective conductors and lowresistance conductor loops through the measuring current transformer! Device damage due to interference pulses! The connecting cable (supply, analogue interface…) must not be routed directly past the current transformer core. Risk...

 Open the catalog to page 9
MRCDB300 series-10

Measuring circuit Control circuit 1 (IC3) Control circuit 2 (IC4) Rated insulation voltage Overvoltage category Pollution degree Operating altitude Insulation coordination acc. to IEC 60664-1/IEC 60664-3Definitions Primary conductors routed through the current transformer Terminal block 1 (24 V, GND, D1, DG, T/R, GND, A, B, X1, X2) Terminal block 2 (11, 12, 14) Terminal block 3 (21,22, 24) 800 V Ml 2 Internal diameter measuring current see "Dimension diagrams", Page 7 Characteristics according to IEC 62020 AC/DC sensitive, type B MRCDB303 (plant protection) 30 mA...3 A (freely configurable),...

 Open the catalog to page 10
MRCDB300 series-11

Multicolour LED red/green, Refer to "System states: LED and output relays", Page 6 Required terminals are included in the scope of delivery. Phoenix Contact The connection conditions of the manufacturer apply. Maximum length connecting cable 10 m Connection properties with ferrules Number of changeover contacts Relay mode Phoenix Contact Switching capacity Contact data acc. to IEC 60947-5-1 Rated operational voltage AC Utilisation category Rated operational current AC Rated operational current AC (for UL applications) Rated operational voltage DC Utilisation category Rated operational current...

 Open the catalog to page 11
MRCDB300 series-12

Ordering details Measuring current transformers Accessories © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 07.2024 unless otherwise indicated. RBENDERBender GmbH & Co. KG Londorfer StraGe 65 35305 Grunberg Germany

 Open the catalog to page 12

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. AN111

    4  Pages

  9. AN450

    4  Pages

  10. AN420

    4  Pages

  11. AN410

    4  Pages

  12. STEP-PS

    8  Pages

  13. CTBC17 series

    8  Pages

  14. IPM1300

    8  Pages

  15. CC613

    6  Pages

  16. ICC1324

    8  Pages

  17. ICC1314

    8  Pages

  18. AGH676S-4

    4  Pages

  19. AGH520S

    4  Pages

  20. AGH204S-4

    4  Pages

  21. AGH150xx

    4  Pages

  22. AT series

    6  Pages

  23. DI-1DL

    4  Pages

  24. SMO482P-12

    4  Pages

  25. DI-2USB

    4  Pages

  26. POWERSCOUT®

    8  Pages

  27. SEB30, SEB60

    8  Pages

  28. VIT-AFSBY

    6  Pages

  29. VIT-A

    6  Pages

  30. RDC125-5S

    12  Pages

  31. RCMB131-01

    4  Pages

  32. RDC121

    7  Pages

  33. RCMB123

    7  Pages

  34. RDC104-4

    6  Pages

  35. RCMB104

    6  Pages

  36. RCMB300-series

    12  Pages

  37. Energy meter

    6  Pages

  38. PEM353

    8  Pages

  39. DS0107

    6  Pages

  40. ESL0107

    4  Pages

  41. ES710

    8  Pages

  42. AGH520S

    4  Pages

  43. RCM410R

    8  Pages

  44. RCMS410

    10  Pages

  45. RCMS425-D

    10  Pages

  46. EDGE500

    12  Pages

  47. Iso415R

    4  Pages

  48. Iso685-x-B

    12  Pages

  49. Iso685-x-P

    14  Pages

  50. Iso685-x

    12  Pages

  51. Data Centers

    16  Pages

  52. RCMB104

    6  Pages

  53. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.