LINETRAXX® VMD421H

LINETRAXX® VMD421H

LINETRAXX® VMD421H

Product catalog summary
Device Features:
  • Monitors undervoltage, overvoltage, and frequency in 3(N)AC systems (70…500/288 V) without external supply voltage.
  • Includes integrated energy backup and various monitoring functions such as asymmetry, phase failure, and phase sequence.
  • Features adjustable switching hysteresis, digital measured value display, and continuous self-monitoring.
  • Equipped with two separate alarm relays and password protection for device settings.
Product Description:

The LINETRAXX® VMD421H is a multi-functional voltage relay designed for monitoring frequency, undervoltage, and overvoltage in 3(N)AC systems. It measures voltages as r.m.s. values and displays them on an LC display. The device can store measured values required to trigger alarms and is equipped with adjustable response times to accommodate installation-specific characteristics.

Typical Applications:
  • Monitoring voltage-sensitive machines and electrical installations.
  • Switching machinery on and off at specific voltage levels.
  • Monitoring stand-by and emergency supply systems.
  • Protecting three-phase motors against phase failure.
Functionality:

Upon applying supply voltage, a start-up delay begins. The device features two adjustable measuring channels for overvoltage and undervoltage. Alarm relays switch based on response values, with adjustable delays for response and release times. Fault memory can be activated to retain alarm parameters even during power failures.

Energy Backup:

In the event of a complete power failure, delay times remain effective during the energy backup period. Alarm parameters are stored if the fault memory is set to continuous mode.

Preset Function:

Automatically sets response values for overvoltage and undervoltage upon initial connection. If no nominal system voltage is detected, manual setting is required.

Technical Data:
  • Insulation coordination according to IEC 60664-1/IEC 60664-3 with a rated insulation voltage of 400 V.
  • Measuring range for AC (L-N) is 0…288 V and for AC (L-L) is 0…500 V.
  • Response values for undervoltage and overvoltage are adjustable, with factory settings provided.
  • Operating temperature range is -25…+55 °C, with EMC compliance according to IEC 61326-1.
Connection and Mounting:
  • Push-wire terminals for connection, suitable for various wire types and sizes.
  • Mounting options include vertical positioning and DIN rail mounting according to IEC 60715.
See more

Catalog excerpts

LINETRAXX® VMD421H-1

Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

 Open the catalog to page 1
LINETRAXX® VMD421H-2

Device features • Undervoltage, overvoltage and frequency monitoring in 3(N)AC systems • Without external supply voltage • Integrated energy backup • Asymmetry, phase failure and phase sequence monitoring • Various monitoring functions selectable <U, >U, <f, >f • Start-up delay, response delay, delay on release • Adjustable switching hysteresis • r.m.s. value measurement (AC+DC) • Digital measured value display via multi-functional LC display • Preset function (automatic setting of basic parameters) • LEDs: Power On, Alarm 1, Alarm 2 • Measured value memory for operating value • Continuous self...

 Open the catalog to page 2
LINETRAXX® VMD421H-3

Relay for overvoltage and undervoltage and frequency monitoring LINETRAXX® VMD421H Wiring diagram Operating elements 12 3 1 - Power On LED "ON" (green), lights when the supply voltage is applied or flashes in the event of system fault alarm 2 - Alarm LED "AL1" (yellow), lights when the set response value >U/<f/>f >f/Asy/PHS is exceeded and flashes in the event of system fault alarm 3 - Alarm LED "AL2" (yellow), lights when value falls below the set response value >U/<f/>f >f/Asy/PHS and flashes in the event of system fault alarm Arrow up button: To change the measured value display, move upwards...

 Open the catalog to page 3
LINETRAXX® VMD421H-4

Undervoltage, overvoltage and frequency monitoring relay LINETRAXX® VMD421H Timing diagram voltage monitoring t toff - Delay on release Timing diagram phase failure, phase sequence, asymmetry t toff - Delay

 Open the catalog to page 4
LINETRAXX® VMD421H-5

Undervoltage, overvoltage and frequency relay LINETRAXX® VMD421H Technical data Displays, memory Rated insulation voltage 400 V Rated impulse voltage/pollution degree 4 kV/3 Display LC display, multifunctional, not illuminated Display range measured value AC/DC 0.500 V Operating uncertainty, voltage at 50/60 Hz ±1.5 %, ±2 digits Operating uncertainty voltage in the range of 15.460 Hz ±3 %, ±2 digits Operating uncertainty, frequency in the range of 15.460 Hz ±0.2 %, ±1 digit History memory (HiS) for the first alarm value data record measured values Fault memory (M) alarm relay on/off/con (on)*...

 Open the catalog to page 5
LINETRAXX® VMD421H-6

Ordering information Nominal system voltage 11Un 3(N)AC Device version with screw terminals on request. 11 Absolute values Open the front plate cover in Screw mounting Note: The upper mounting clip must be ordered separately (see ordering information). E& BENDER The Power in Electrical Safety6 P.O. Box 1161 • 35301 Gruenberg • Germany Londorfer Strasse 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-Mail: [email protected] • www.bender.de

 Open the catalog to page 6

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.