Product Overview
The LINETRAXX® RCMS460/RCMS490 are advanced multi-channel residual current monitors suitable for earthed AC, DC, and AC/DC systems (TN and TT systems). They are designed to detect AC, pulsed DC, and AC/DC currents, with models RCMS460-D/-L and RCMS490-D/-L capable of monitoring up to 1080 channels via a BMS bus.
Specifications
- 12 measuring channels per device.
- Compatible with various measuring current transformers.
- Fast scanning time of ≤180 ms.
- Two response values with separate alarm relays.
- History memory for 300 records and data logger for 300 records per channel.
- True RMS value measurement and harmonics analysis.
- Optional sensitivity to AC, pulsed DC, or AC/DC currents.
Applications
- Monitoring residual, fault, and rated currents (0…2000 Hz).
- Fire hazard monitoring in flammable environments.
- EMC monitoring of TN-S systems.
- Monitoring N and PE conductors for overload and current-free status.
- Personnel and fire protection through rapid disconnection.
Device Features
- Backlit graphical display and alarm LEDs.
- Data exchange via BMS bus with password protection.
- Continuous CT connection monitoring.
- RoHS compliant.
Functionality
The devices measure currents as true RMS values, displaying them on an LC display. Alarm relays activate if response values are exceeded. Devices can be tested via a test button, with parameters set through the display or connected panels.
Device Variants
- RCMS460-D: Detailed local display.
- RCMS460-L: Two-digit display for device address.
- RCMS490-D/L: Includes galvanically isolated alarm contact.
- RCMS-D4/L4: For current measurements with type A transformers.
Standards and Approvals
- Complies with DIN EN 62020 (VDE 0663):2005-11.
- Meets UL508 and UL1053 standards for industrial control equipment.
Wiring and Connections
Specific wiring configurations are required for power supply, measuring current transformers, and external test/reset buttons, with detailed connection instructions provided.
Frequency Settings
Adjustable frequency response for fire, personnel, or plant protection, with specific settings for different protection types.
System Design Examples
- Minimum System: RCMS460-D with 12 measuring points.
- Standard System: RCMS460-D, RCMS460-L, and protocol converter COM465IP.
Specifications
- Insulation Coordination: Adheres to IEC 60664-1/IEC 60664-3 standards.
- Measuring Circuit: Uses external transformers from CTAC, WR, WS, WF, CTUB100, and CTBS25 series.
- Inputs/Outputs: Includes test/reset buttons and RS-485/BMS interface.
- Environmental Conditions: Operating temperature from -25 to +55 °C, EMC compliant to DIN EN 62020.
Components and Accessories
- Power Supply Units: Various models for different CTUB100 series transformers.
- Condition Monitors: COM465IP with multiple function packages.
- Measuring Current Transformers: Available in various types and sizes.
Ordering Information
Includes detailed part numbers and descriptions for RCMS460/490 models and accessories.
Installation and Connection
- Connection Guidelines: Use copper wire and specific conductor sizes for UL applications.
- Mounting: Options for screw and DIN rail mounting.
Software and Display
- Software Versions: Different versions for measurement techniques and display.
- Display Features: Backlit graphical and 7-segment displays with history memory and data logging.
See more

Catalog excerpts

LINETRAXX® RCMS460 / RCMS490-1

LINETRAXX® RCMS460/RCMS490 Multi-channel residual current monitors for earthed AC, DC and AC/DC systems (TN and TT systems) AC, pulsed DC and AC/DC sensitive

 Open the catalog to page 1
LINETRAXX® RCMS460 / RCMS490-2

Multi-channel AC, pulsed DC and AC/DC sensitive residual current monitors for earthed AC, DC and AC/DC systems (TN and TT systems) Device features • Optional AC, pulsed DC or AC/DC sensitive measurement by selecting the respective measuring current transformer for each channel • True r.m.s. value measurement • 12 measuring channels per device for residual current measurement or digital input • Up to 90 RCMS... monitors, up to1080 measuring channels in the system • Fast parallel scanning for all channels • Response ranges: • Preset function • Adjustable time delays • The frequency response characteristics...

 Open the catalog to page 2
LINETRAXX® RCMS460 / RCMS490-3

Residual current monitors LINETRAXX® RCMS460/RCMS490 Digital input Each individual channel can be used for one of the following monitoring functions: • As digital input using a potential-free contact 1/0 • O r for current or residual current monitoring in combination with measuring current transformers. History memory in RCMS460-D, RCMS490-D The device utilises a history memory for failsafe storing of up to 300 data records (date, time, channel, event code, measured value), so that all data about an outgoing circuit or an area can be traced back at any time (what happened when). Analysis of harmonics...

 Open the catalog to page 3
LINETRAXX® RCMS460 / RCMS490-4

Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Overview of device types

 Open the catalog to page 4
LINETRAXX® RCMS460 / RCMS490-5

Residual current monitors LINETRAXX® RCMS460/RCMS490 Operating and display elements RCMS460-D The frequency response of the equipment can be set to a linear frequency response (up to the maximum frequency of Hz) if used for fire protection or to a frequency response in accordance with IEC 60990 for personnel protection. For plant protection, the residual current is measured up to the rated system frequency. The figure below shows the corresponding frequency response. Frequency curves L ED ALARM “2” lights up when the measured value falls below or exceeds the response value in a measuring channel...

 Open the catalog to page 5
LINETRAXX® RCMS460 / RCMS490-6

Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Connection of supply voltage Us (see ordering information): we recommend the use of 6 A fuses. Connection of measuring current transformers CT1...CT12. Either Type A or Type B measuring current transformers can be selected for each measuring channel. Six CTUB100 series measuring current transformers require one STEP-PS power supply unit. The channels k9...k12 of the device versions RCMS460-D4/-L4 require the connection of Type A measuring current transformers. BMS bus (RS-485 interface with BMS protocol) External reset button (N/O...

 Open the catalog to page 6
LINETRAXX® RCMS460 / RCMS490-7

Residual current monitors LINETRAXX® RCMS460/RCMS490 transformers (pulsed current sensitive) (AC/DC current sensitive) -|s| Connection WF... series measuring current transformers Anschluss Messstromwandler Serie CTBS25 (allstromsensitiv) j The connections k and l at the residual current monitor must not be interchanged.

 Open the catalog to page 7
LINETRAXX® RCMS460 / RCMS490-8

Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Example for a system design of - standard system consisting of an RCMS460-D and RCMS460-L and a protocol converter COM465IP kijyjLk2j |_k3jLULMJ |j<5j|_j_|Ijcej LkULUU^J [MJLULmJ |_ksj| i like Note: 1 - When usingAC/DC current sensitive measuring current transformers of the CTUB100 and CTBS25 series , a DC 24 V power supply unit (e.g. STEP-PS series) is required to supply the measuring current transformers with voltage. For this purpose, the technical data of the respective...

 Open the catalog to page 8
LINETRAXX® RCMS460 / RCMS490-9

Residual current monitors LINETRAXX® RCMS460/RCMS490 Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 for the versions: a) RCMS4x0-D1 Supply voltage Us Supply voltage frequency Rated insulation voltage 100 V Rated impulse voltage/pollution degree 2.5 kV/3 Overvoltage category III Protective separation (reinforced insulation) between (A1, A2) - (k1, l…k12, R, T/R, T, A, B) Voltage test acc. to IEC 61010-1 1.344 kV Rated insulation voltage 250 V Rated impulse voltage/pollution degree 4 kV/3 Overvoltage category III Basic insulation between (A1, A2), (k1, l…k12, R, T/R, T,...

 Open the catalog to page 9
LINETRAXX® RCMS460 / RCMS490-10

Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Test/reset button internal/external Cable length for external test/reset button 0.. .10 m Baud rate Cable length Cable (shielded, shield connected to PE on one side) recommended: min. J-Y(St)Y min. 2x0.8 Terminating resistor Use copper wire only! Use 60/70 °C copper conductors only! Connection screw terminals Connection properties: Multi-conductor connection (2 conductors with the same cross section): Minimum contact rating 10 mA/5 V DC Classification of climatic conditions acc. to IEC 60721 (related to temperature and relative humidity)...

 Open the catalog to page 10
LINETRAXX® RCMS460 / RCMS490-11

Residual current monitors LINETRAXX® RCMS460/RCMS490

 Open the catalog to page 11
LINETRAXX® RCMS460 / RCMS490-12

Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Suitable system components

 Open the catalog to page 12
LINETRAXX® RCMS460 / RCMS490-13

Residual current monitors LINETRAXX® RCMS460/RCMS490 Measuring current transformers Pulsating current sensitive measuring current transformers AC/DC sensitive measuring current transformers for for RCMS460/490 RCMS460/490 Other measuring current transformer types on request. Connection cable for CTUB... series measuring current transformers Flexible measuring current transformers (pulsed DC sensitive) for RCMS460/490 WF... series measuring current transformers consist of one flexible WF... series measuring current transformer and one RCC420 signal converter.

 Open the catalog to page 13
LINETRAXX® RCMS460 / RCMS490-14

Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 07.2023 unless otherwise indicated.

 Open the catalog to page 14

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.