LINETRAXX® RCMS460/RCMS490 Multi-channel residual current monitors for earthed AC, DC and AC/DC systems (TN and TT systems) AC, pulsed DC and AC/DC sensitive
Open the catalog to page 1Multi-channel AC, pulsed DC and AC/DC sensitive residual current monitors for earthed AC, DC and AC/DC systems (TN and TT systems) Device features • Optional AC, pulsed DC or AC/DC sensitive measurement by selecting the respective measuring current transformer for each channel • True r.m.s. value measurement • 12 measuring channels per device for residual current measurement or digital input • Up to 90 RCMS... monitors, up to1080 measuring channels in the system • Fast parallel scanning for all channels • Response ranges: • Preset function • Adjustable time delays • The frequency response characteristics...
Open the catalog to page 2Residual current monitors LINETRAXX® RCMS460/RCMS490 Digital input Each individual channel can be used for one of the following monitoring functions: • As digital input using a potential-free contact 1/0 • O r for current or residual current monitoring in combination with measuring current transformers. History memory in RCMS460-D, RCMS490-D The device utilises a history memory for failsafe storing of up to 300 data records (date, time, channel, event code, measured value), so that all data about an outgoing circuit or an area can be traced back at any time (what happened when). Analysis of harmonics...
Open the catalog to page 3Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Overview of device types
Open the catalog to page 4Residual current monitors LINETRAXX® RCMS460/RCMS490 Operating and display elements RCMS460-D The frequency response of the equipment can be set to a linear frequency response (up to the maximum frequency of Hz) if used for fire protection or to a frequency response in accordance with IEC 60990 for personnel protection. For plant protection, the residual current is measured up to the rated system frequency. The figure below shows the corresponding frequency response. Frequency curves L ED ALARM “2” lights up when the measured value falls below or exceeds the response value in a measuring channel...
Open the catalog to page 5Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Connection of supply voltage Us (see ordering information): we recommend the use of 6 A fuses. Connection of measuring current transformers CT1...CT12. Either Type A or Type B measuring current transformers can be selected for each measuring channel. Six CTUB100 series measuring current transformers require one STEP-PS power supply unit. The channels k9...k12 of the device versions RCMS460-D4/-L4 require the connection of Type A measuring current transformers. BMS bus (RS-485 interface with BMS protocol) External reset button (N/O...
Open the catalog to page 6Residual current monitors LINETRAXX® RCMS460/RCMS490 transformers (pulsed current sensitive) (AC/DC current sensitive) -|s| Connection WF... series measuring current transformers Anschluss Messstromwandler Serie CTBS25 (allstromsensitiv) j The connections k and l at the residual current monitor must not be interchanged.
Open the catalog to page 7Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Example for a system design of - standard system consisting of an RCMS460-D and RCMS460-L and a protocol converter COM465IP kijyjLk2j |_k3jLULMJ |j<5j|_j_|Ijcej LkULUU^J [MJLULmJ |_ksj| i like Note: 1 - When usingAC/DC current sensitive measuring current transformers of the CTUB100 and CTBS25 series , a DC 24 V power supply unit (e.g. STEP-PS series) is required to supply the measuring current transformers with voltage. For this purpose, the technical data of the respective...
Open the catalog to page 8Residual current monitors LINETRAXX® RCMS460/RCMS490 Technical data Insulation coordination acc. to IEC 60664-1/IEC 60664-3 for the versions: a) RCMS4x0-D1 Supply voltage Us Supply voltage frequency Rated insulation voltage 100 V Rated impulse voltage/pollution degree 2.5 kV/3 Overvoltage category III Protective separation (reinforced insulation) between (A1, A2) - (k1, l…k12, R, T/R, T, A, B) Voltage test acc. to IEC 61010-1 1.344 kV Rated insulation voltage 250 V Rated impulse voltage/pollution degree 4 kV/3 Overvoltage category III Basic insulation between (A1, A2), (k1, l…k12, R, T/R, T,...
Open the catalog to page 9Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Test/reset button internal/external Cable length for external test/reset button 0.. .10 m Baud rate Cable length Cable (shielded, shield connected to PE on one side) recommended: min. J-Y(St)Y min. 2x0.8 Terminating resistor Use copper wire only! Use 60/70 °C copper conductors only! Connection screw terminals Connection properties: Multi-conductor connection (2 conductors with the same cross section): Minimum contact rating 10 mA/5 V DC Classification of climatic conditions acc. to IEC 60721 (related to temperature and relative humidity)...
Open the catalog to page 10Residual current monitors LINETRAXX® RCMS460/RCMS490
Open the catalog to page 11Residual current monitors LINETRAXX® RCMS460/RCMS490 Kr BENDER Suitable system components
Open the catalog to page 12Residual current monitors LINETRAXX® RCMS460/RCMS490 Measuring current transformers Pulsating current sensitive measuring current transformers AC/DC sensitive measuring current transformers for for RCMS460/490 RCMS460/490 Other measuring current transformer types on request. Connection cable for CTUB... series measuring current transformers Flexible measuring current transformers (pulsed DC sensitive) for RCMS460/490 WF... series measuring current transformers consist of one flexible WF... series measuring current transformer and one RCC420 signal converter.
Open the catalog to page 13Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 07.2023 unless otherwise indicated.
Open the catalog to page 144 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
12 Pages
10 Pages
10 Pages
6 Pages
6 Pages
12 Pages
12 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
6 Pages
8 Pages
6 Pages
8 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
4 Pages
10 Pages
6 Pages
6 Pages
6 Pages
12 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
7 Pages
8 Pages
12 Pages
10 Pages
8 Pages
6 Pages
10 Pages
6 Pages
6 Pages
6 Pages
10 Pages
8 Pages
6 Pages
6 Pages
6 Pages
8 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
6 Pages
12 Pages
12 Pages
12 Pages
4 Pages
7 Pages
7 Pages
2 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
12 Pages
14 Pages
10 Pages
4 Pages
14 Pages
6 Pages
16 Pages
6 Pages
8 Pages
6 Pages
4 Pages
8 Pages
4 Pages
8 Pages
8 Pages
10 Pages
8 Pages
8 Pages
6 Pages
8 Pages
6 Pages
4 Pages
6 Pages
6 Pages
10 Pages
8 Pages
8 Pages
6 Pages
6 Pages
8 Pages
6 Pages
10 Pages
6 Pages
6 Pages
2 Pages
6 Pages
10 Pages
10 Pages
10 Pages
8 Pages
8 Pages
4 Pages
12 Pages
8 Pages
10 Pages
10 Pages
12 Pages
4 Pages
12 Pages
14 Pages
12 Pages
16 Pages
6 Pages
10 Pages
486 Pages