1. Catalogs
  2. BENDER GmbH & Co KG
  3. LINETRAXX® CTAS series

LINETRAXX® CTAS series
1 /8Pages

LINETRAXX® CTAS series

LINETRAXX® CTAS series
1 /8Pages

Catalog excerpts

LINETRAXX® CTAS series-1

LINETRAXX® CTAS seriesDivisible measuring current transformer Hr BENDER CTAS120

 Open the catalog to page 1
LINETRAXX® CTAS series-2

Divisible measuring current transformers Device features Product description The divisible measuring current transformers of the CTAS series allow the measuring current transformer to be opened by means of a locking button and place them around the conductors to be monitored. This enables easy retrofitting in existing systems. The divisible, highly sensitive CTAS series measuring current transformers in combination with RCM or RCMS series residual current monitors and evaluators convert AC currents into an evaluable measurement signal. They are also suitable for use in insulation fault location...

 Open the catalog to page 2
LINETRAXX® CTAS series-3

Dimension diagrams Divisible measuring current transformers LINETRAXX® CTAS series 1) Mounting clip recommended for CTAS50(/01) and CTAS80(/01). For CTAS120(/01) reduced mechanical conditions apply.

 Open the catalog to page 3
LINETRAXX® CTAS series-4

Divisible measuring current transformers LINETRAXX® CTAS series Z BENDER Divisible measuring current transformers LINETRAXX® CTAS series Z BENDER * For CTAS120(/01) reduced mechanical conditions apply with this mounting.

 Open the catalog to page 4
LINETRAXX® CTAS series-5

Divisible measuring current transformers LINETRAXX® CTAS series 4 x M4 (3,5 Nm / 31 lb.in) 4 x Flat washer Z type Ø 80, 120 mm: 9…12 mm / 0.35…0.47 in * Reduced mechanical conditions apply to all CTAS with this mounting.

 Open the catalog to page 5
LINETRAXX® CTAS series-6

Divisible measuring current transformers LINETRAXX® CTAS series Technical data Insulation coordination according to IEC 60664-1 Rated voltage CTAS50(/01) CTAS80(/01)/CTAS120(/01) Overvoltage category Rated impulse voltage/pollution degree Environment Operating temperature 500 V 630 V III 8 kV/3 Insulation coordination according to IEC 61869-1 Rated voltage Measuring current transformer circuit CTAS… Rated transformation ratio Kr600/1 Rated continuous thermal current* Icth 125 A Frequency range 42 Hz…3 kHz Rated short-time thermal current* Ith 2.4 kA/1 s Rated dynamic current* Idyn 6.0 kA/40 ms...

 Open the catalog to page 6
LINETRAXX® CTAS series-7

Divisible measuring current transformers LINETRAXX® CTAS series Installation instructions • Do not route any shielded cables through the measuring current transformer. • Failure to comply with the installation instructions may result in non-compliance with the tolerances and normative requirements of the connected evaluators. PE L1 L2 L3 N Never route an existing protective conductor through the transformer. P1 (K): YE All power-carrying cables must be routed together through the measuring current transformer. The primary conductors should only be bent from the specified minimum distance. The...

 Open the catalog to page 7
LINETRAXX® CTAS series-8

BENDER Group CTAS_D00452_01_D_XXEN/08.2022 / © Bender GmbH & Co. KG, Germany – subject to change! The specified standards take into account the edition valid until 08.2022 unless otherwise indicated. Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • [email protected] • www

 Open the catalog to page 8

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.