Catalog excerpts

LINETRAXX® CMD420/CMD421-1

Current monitoring devices for monitoring 3AC currents for overcurrent and undercurrent using measuring current transformers or current monitoring with window discriminator function

 Open the catalog to page 1
LINETRAXX® CMD420/CMD421-2

Current monitoring devices LINETRAXX® CMD420/CMD421 Z BENDER LINETRAXX® CMD420/CMD421 Current monitoring devices for monitoring 3AC currents for overcurrent or undercurrent using measuring current transformers or with window discriminator function Device features • Undercurrent and overcurrent monitoring in AC systems, current monitoring with window discriminator function • Current monitoring using standard current transformers: • Two separately adjustable alarm relays with one changeover contact each (K1, K2) • Fault memory behaviour for the alarm relays selectable • Digital measured value display...

 Open the catalog to page 2
LINETRAXX® CMD420/CMD421-3

Current monitoring devices LINETRAXX® CMD420/CMD421 1 - Power On LED "ON" (green); lights when supply voltage is applied and flashes in the event of system fault alarm 2 - Alarm LED "AL1" (yellow): lights when the value exceeds or falls below the set response values and flashes in the event of system fault alarm 3 - Alarm LED "AL2" (yellow): lights when the value exceeds or falls below the set response values and flashes in the event of system fault alarm Arrow up button: To change the measured value display, move upwards in the menu or to change parameters. To call up the self test: press the...

 Open the catalog to page 3
LINETRAXX® CMD420/CMD421-4

Current monitoring devices LINETRAXX® CMD420/CMD421 Z BENDER Technical data CMD420... Rated insulation voltage AC 250 V Rated impulse voltage/pollution degree 6 kV/3 CMD421... Rated insulation voltage Rated impulse voltage/pollution degree Basic insulation between: Basic insulation between: Time response Start-up delay t Response delay ton1 Response delay ton2 Delay on release toff Resolution of setting t, ton1/2, toff (0.10 s) Resolution of setting t, ton1/2, toff (10.99 s) Resolution of setting t, ton1/2, toff (100.300 s) Device release time tre Release time toff Supply voltage Supply voltage...

 Open the catalog to page 4
LINETRAXX® CMD420/CMD421-5

Current monitoring devices LINETRAXX® CMD420/CMD421 Connection Connection properties rigid flexible without ferrules with ferrules Stripping length Opening force Test opening, diameter Other Operating mode Mounting Degree of protection, internal components (IEC 60529) Degree of protection, terminals (IEC 60529) Enclosure material Flammability class DIN rail mounting acc. to Screw mounting Documentation number Weight continuous operation any position IP30 IP20 polycarbonate UL94V-0 IEC 60715 2 x M4 with mounting clip D00101 < 150 g Ordering information Dimension diagram XM420 Dimensions in mm

 Open the catalog to page 5
LINETRAXX® CMD420/CMD421-6

BENDER Group CMD420-421_D00101_02_D_XXEN / 01.2022 / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 01.2022 unless otherwise indicated. Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • [email protected] • www

 Open the catalog to page 6

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.