1. Catalogs
  2. BENDER GmbH & Co KG
  3. ISOSCAN® EDS150/151

ISOSCAN® EDS150/151
1 /6Pages

ISOSCAN® EDS150/151

ISOSCAN® EDS150/151
1 /6Pages

Catalog excerpts

ISOSCAN® EDS150/151-1

Insulation fault locator with integrated measuring current transformers for EDS systems

 Open the catalog to page 1
ISOSCAN® EDS150/151-2

Insulation fault locator with integrated measuring current transformers for EDS systems Device features • Insulation fault location in AC, AC/DC and DC IT systems • 6 measuring channels with measuring current transformer per EDS150/151 • Up to 528 measuring channels can be combined by the BMS bus in the IT system being monitored: 88 x 6 measuring channels • A response time of up to 8 s in the AC system acc. to IEC 61557-9 • RS-485 interface with BMS protocol • Cyclical self test The insulation fault locator EDS150/151 in conjunction with the ISOMETER® IRDH575 or the locating current injector...

 Open the catalog to page 2
ISOSCAN® EDS150/151-3

Insulation fault locator ISOSCAN® EDS150/151 1 - Opening for screw mounting 2 - Alarm LEDs measuring channels “K1…K6” 3- C able lead-through of the measuring current transformers for the measuring channels K1…K6 4 - “ ON/COM” LED: Power On LED and bus activity 5 - Set the ones position of the BMS address 6 - Set the tens position of the BMS address 7 - Connection to the supply voltage 8 - Connection RS-485, BMS bus Wiring diagram TN system 10 Bus termination 120 Ω, internal switch 6 - Insulation fault locator EDS150/151 with integrated measuring current transformers 4- A larm indicator and test...

 Open the catalog to page 3
ISOSCAN® EDS150/151-4

Insulation fault locator ISOSCAN® EDS150/151 Z BENDER Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated insulation voltage AC 250 V Rated impulse voltage/pollution degree 6 kV/3 Nominal system voltage Un Supply voltage: Frequency range of the supply voltage Power consumption AC Maximum ambient temperature 55 °C Classification of climatic conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2K3 (except condensation and formation of ice) Long-term storage (IEC 60721-3-1) 1K4 (except condensation and formation...

 Open the catalog to page 4
ISOSCAN® EDS150/151-5

Insulation fault locator ISOSCAN® EDS150/151 Ordering information A According to IEC 60364-7-710 only power supply units providing "Safe separation" (reinforced insulation) may be used for the supply voltage between the primary and secondary side. All power supply units listed above comply with this requirement! Dimension diagram

 Open the catalog to page 5
ISOSCAN® EDS150/151-6

E& BENDER The Power in Electrical Safety6 P.O. Box 1161 • 35301 Gruenberg • Germany Londorfer Strasse 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-Mail: [email protected] • www.bender.de

 Open the catalog to page 6

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.