1. Catalogs
  2. BENDER GmbH & Co KG
  3. ISOMETER® isoPV1685RTU

ISOMETER® isoPV1685RTU
1 /8Pages

ISOMETER® isoPV1685RTU

ISOMETER® isoPV1685RTU
1 /8Pages

Catalog excerpts

ISOMETER® isoPV1685RTU-1

ISOMETER® isoPV1685RTU Insulation monitoring device for unearthed photovoltaic systems Image similar

 Open the catalog to page 1
ISOMETER® isoPV1685RTU-2

for unearthed photovoltaic systems Device features ISOMETER® for photovoltaic systems. • Insulation monitoring of large PV systems • Measurement of insulation faults 200 Q...1 MO • Automatic adjustment to high system leakage capacitances • Combination of AMPPLUS and other profile-specific measurement methods • Separately adjustable response values Ran1 (Alarm 1) and Ran2 (Alarm 2) for prewarning and alarm • Connection monitoring of L+, L- for polarity reversal • Device self test with automatic alarm message in the event of a fault • gSD card (not equipped) with data logger and history memory...

 Open the catalog to page 2
ISOMETER® isoPV1685RTU-3

Wiring diagram Digital input: Reset / (Memory) Digital input: Test CAN1, CAN2 No function RS485 Term. RS-485 termination off / on A, B, S RS-485 bus connection (A, B) BMS protocol: PE potential, connect one end of shield (S) Relay output for internal device errors (LED SERVICE) Relay output for alarm insulation faults (LED ALARM 2) Relay output for prewarning insulation faults (LED ALARM 1) Separate connection of E (earth) and KE (reference) to PE Connection to supply voltage (via fuses, 2 A each) Connection to L1/+ of the IT system via 1 A fuse Connection to L2/− of the IT system via 1 A fuse...

 Open the catalog to page 3
ISOMETER® isoPV1685RTU-4

Diagrams System leakage capacitance The determination of the leakage capacitance depends on the size of the insulation resistance. Examples – – minimum measurable leakage capacitance at RF = 50 kΩ: 35 µF minimum measurable leakage capacitance at RF = 5 kΩ: 210 µF Response time ADVICE In the case of a leakage capacitance of 2000 µF, the measuring range for the insulation resistance is limited to 50 kΩ.

 Open the catalog to page 4
ISOMETER® isoPV1685RTU-5

Technical data Rated impulse voltage 10 kV Voltage range Nominal system voltage range Un Nominal frequency range Tolerance of Un Supply voltage Us Power consumption Serial interface Modbus RTU (Slave); switchable Connection Terminals A/B Shielded cable 2-core, > 0.6 mm2, e.g. J-Y(St)Y 2x0.6 (shield to functional earth on one end) Terminating resistor, can be connected (RS-485 Term.) 120 O (0.5 W) Device address, BMS bus or Modbus adjustable 2.17 Measuring circuit for insulation monitoring Switching elements Measuring voltage Um (peak) ± 50 V Permissible extraneous DC voltage Ufg < DC 1500 V Permissible...

 Open the catalog to page 5
ISOMETER® isoPV1685RTU-6

Ambient temperature during operation -40.+70 °C Ambient temperature transport -40.+80 °C Ambient temperature long-term storage -25...+80 °C Classification of climatic conditions acc. to IEC 60721: The ISOMETER® isoPV1685RTU was developed in compliance with the following standards: Classification of mechanical conditions acc. to IEC 60721: Atmospheric pressure 700.1060 hPa (max. height 4000 m) continuous operation vertical, system coupling on top lens head screw DIN7985TX 4.5 Nm IP30 IP30 <1300g Operating mode Position of normal use PCB fixation Tightening torque Degree of protection, internal...

 Open the catalog to page 6
ISOMETER® isoPV1685RTU-7

Ordering details Model Response value Supply voltage

 Open the catalog to page 7
ISOMETER® isoPV1685RTU-8

Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until unless otherwise indicated.

 Open the catalog to page 8

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages