ISOMETER® isoPV1685RTU Insulation monitoring device for unearthed photovoltaic systems Image similar
Open the catalog to page 1for unearthed photovoltaic systems Device features ISOMETER® for photovoltaic systems. • Insulation monitoring of large PV systems • Measurement of insulation faults 200 Q...1 MO • Automatic adjustment to high system leakage capacitances • Combination of AMPPLUS and other profile-specific measurement methods • Separately adjustable response values Ran1 (Alarm 1) and Ran2 (Alarm 2) for prewarning and alarm • Connection monitoring of L+, L- for polarity reversal • Device self test with automatic alarm message in the event of a fault • gSD card (not equipped) with data logger and history memory...
Open the catalog to page 2Wiring diagram Digital input: Reset / (Memory) Digital input: Test CAN1, CAN2 No function RS485 Term. RS-485 termination off / on A, B, S RS-485 bus connection (A, B) BMS protocol: PE potential, connect one end of shield (S) Relay output for internal device errors (LED SERVICE) Relay output for alarm insulation faults (LED ALARM 2) Relay output for prewarning insulation faults (LED ALARM 1) Separate connection of E (earth) and KE (reference) to PE Connection to supply voltage (via fuses, 2 A each) Connection to L1/+ of the IT system via 1 A fuse Connection to L2/− of the IT system via 1 A fuse...
Open the catalog to page 3Diagrams System leakage capacitance The determination of the leakage capacitance depends on the size of the insulation resistance. Examples – – minimum measurable leakage capacitance at RF = 50 kΩ: 35 µF minimum measurable leakage capacitance at RF = 5 kΩ: 210 µF Response time ADVICE In the case of a leakage capacitance of 2000 µF, the measuring range for the insulation resistance is limited to 50 kΩ.
Open the catalog to page 4Technical data Rated impulse voltage 10 kV Voltage range Nominal system voltage range Un Nominal frequency range Tolerance of Un Supply voltage Us Power consumption Serial interface Modbus RTU (Slave); switchable Connection Terminals A/B Shielded cable 2-core, > 0.6 mm2, e.g. J-Y(St)Y 2x0.6 (shield to functional earth on one end) Terminating resistor, can be connected (RS-485 Term.) 120 O (0.5 W) Device address, BMS bus or Modbus adjustable 2.17 Measuring circuit for insulation monitoring Switching elements Measuring voltage Um (peak) ± 50 V Permissible extraneous DC voltage Ufg < DC 1500 V Permissible...
Open the catalog to page 5Ambient temperature during operation -40.+70 °C Ambient temperature transport -40.+80 °C Ambient temperature long-term storage -25...+80 °C Classification of climatic conditions acc. to IEC 60721: The ISOMETER® isoPV1685RTU was developed in compliance with the following standards: Classification of mechanical conditions acc. to IEC 60721: Atmospheric pressure 700.1060 hPa (max. height 4000 m) continuous operation vertical, system coupling on top lens head screw DIN7985TX 4.5 Nm IP30 IP30 <1300g Operating mode Position of normal use PCB fixation Tightening torque Degree of protection, internal...
Open the catalog to page 6Ordering details Model Response value Supply voltage
Open the catalog to page 7Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until unless otherwise indicated.
Open the catalog to page 84 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
12 Pages
10 Pages
10 Pages
6 Pages
6 Pages
12 Pages
12 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
6 Pages
8 Pages
6 Pages
8 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
4 Pages
10 Pages
6 Pages
6 Pages
6 Pages
12 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
7 Pages
8 Pages
12 Pages
10 Pages
8 Pages
6 Pages
10 Pages
6 Pages
6 Pages
6 Pages
10 Pages
8 Pages
6 Pages
6 Pages
6 Pages
8 Pages
6 Pages
6 Pages
6 Pages
6 Pages
8 Pages
6 Pages
12 Pages
12 Pages
12 Pages
4 Pages
7 Pages
7 Pages
2 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
4 Pages
8 Pages
12 Pages
14 Pages
10 Pages
4 Pages
14 Pages
6 Pages
16 Pages
6 Pages
8 Pages
6 Pages
4 Pages
8 Pages
4 Pages
8 Pages
8 Pages
10 Pages
8 Pages
8 Pages
6 Pages
8 Pages
6 Pages
4 Pages
6 Pages
6 Pages
10 Pages
8 Pages
6 Pages
6 Pages
8 Pages
6 Pages
10 Pages
6 Pages
6 Pages
2 Pages
6 Pages
10 Pages
10 Pages
10 Pages
8 Pages
8 Pages
4 Pages
12 Pages
8 Pages
10 Pages
10 Pages
12 Pages
4 Pages
12 Pages
14 Pages
12 Pages
16 Pages
6 Pages
14 Pages
10 Pages
486 Pages