ISOMETER® isoPV1685DP

Product catalog summary
Intended Use
The ISOMETER® isoPV1685DP is designed for insulation monitoring in large photovoltaic systems up to AC 1000 V and DC 1500 V, configured as IT systems. It is particularly effective in systems with high leakage capacitances due to interference suppression methods. The device automatically adapts to these capacitances and generates locating current pulses for insulation fault location. Custom parameter settings are necessary to comply with standards and adapt to local conditions. Unauthorized modifications are prohibited.

Functional Description
The device uses an active measuring pulse to monitor insulation resistance. It has two alarm levels: prewarning (Ran1) and alarm (Ran2), indicated by LEDs and relay switches. A third relay indicates device or connection failures. The device can be installed in a control cabinet, and only one ISOMETER® should be connected in a galvanically connected system.

Device Features
The isoPV1685DP features automatic adjustment to high leakage capacitances, separate adjustable response values for alarms, connection monitoring, and a self-test function. It includes a history memory for storing alarm messages and has programmable digital inputs/outputs. The device has a high-resolution graphic display and supports remote settings and diagnostics via the Internet.

Technical Data
The device operates with a supply voltage of DC 18-30 V and monitors systems with nominal voltages up to AC 1000 V and DC 1500 V. It supports a frequency range of DC, 50 Hz, and 60 Hz. The measuring circuit can handle system leakage capacitances up to 4000 μF, with response values ranging from 200 Ω to 200 kΩ.

Interfaces and Connections
The isoPV1685DP includes an RS-485 interface for data exchange and supports BMS and Modbus RTU protocols. It has three changeover contacts for alarms and device errors, with a rated operational voltage of 230 V and current of 5 A.

Environmental and Mechanical Conditions
The device is suitable for use in environments with relative humidity from 10% to 100% and temperatures from -40°C to +70°C. It complies with various IEC standards for EMC and mechanical conditions.

Standards and Approvals
The device complies with standards such as DIN EN 60664-1, DIN EN 61557-8, and IEC 61326-2-4, ensuring its reliability and safety in photovoltaic applications.

Ordering Details
The model isoPV1685DP-425 is available with a response value range of 200 Ω to 200 kΩ, suitable for systems with AC 0-1000 V and DC 0-1500 V, and operates on a DC 24 V supply.
See more

Catalog excerpts

ISOMETER® isoPV1685DP-1

ISOMETER® isoPV1685DP Insulation monitoring device for unearthed photovoltaic systems Image similar

 Open the catalog to page 1
ISOMETER® isoPV1685DP-2

Insulation monitoring device for unearthed photovoltaic systems Intended use The device isoPV1685DP is used for insulation monitoring of large photovoltaic systems up to AC 1000 V and DC 1500 V designed as IT systems. The measurement method specially developed for slow voltage fluctuations (MPP tracking) monitors the insulation resistance even in systems equipped with large solar generator panels where extremely high system leakage capacitances against earth exist due to interference suppression methods. Adaptation to system-related high leakage capacitances also occurs automatically within the...

 Open the catalog to page 2
ISOMETER® isoPV1685DP-3

Device features ISOMETER® for photovoltaic systems. • Insulation monitoring of large PV systems • Automatic adjustment to high system leakage capacitances • Combination of AMPPLUS and other profile-specific measurement methods • Separately adjustable response values Ran1 (Alarm 1) and Ran2 (Alarm 2) for prewarning and alarm • Connection monitoring • Device self test with automatic alarm message in the event of a fault • History memory with real-time clock (buffer for 30 days) for storing 1023 alarm messages with date and time • Freely programmable digital inputs/outputs • Separate relays for...

 Open the catalog to page 3
ISOMETER® isoPV1685DP-4

Wiring diagram Digital input: no function Digital input: Start insulation fault location in manual mode CAN1, CAN2 No function RS485 Term. RS-485 termination off / on A, B, S RS-485 bus connection (A, B) BMS protocol: PE potential, connect one end of shield (S) Relay output for internal device errors (LED SERVICE) Relay output for alarm insulation faults (LED ALARM 2) Relay output for prewarning insulation faults (LED ALARM 1) Separate connection of E (earth) and KE (reference) to PE Connection to supply voltage (via fuses, 2 A each) Connection to L1/+ of the IT system via 1 A fuse

 Open the catalog to page 4
ISOMETER® isoPV1685DP-5

Device profiles The adaptation to different applications is achieved by selecting a device profile. The following device profiles are available. Response time Response value Response time Response value

 Open the catalog to page 5
ISOMETER® isoPV1685DP-6

Leakage capacitance diagram The determination of the leakage capacitance depends on the size of the insulation resistance. The following diagrams show the relationship Example: Insulation resistance 50 kΩ => min. measurable leakage capacitance 35 μF Insulation resistance 5 kΩ => min. measurable leakage capacitance 210 μF

 Open the catalog to page 6
ISOMETER® isoPV1685DP-7

Technical dataInsulation coordination acc. to IEC 60664-1/IEC 60664-3 Measuring circuit for insulation monitoring Measuring circuit (IC1) Supply circuit (IC2) Output circuit 1 (IC3) Output circuit 2 (IC4) Output circuit 3 (IC5) Control circuit (IC6) Rated voltage Measuring voltage Um (peak) ± 50 V Measuring current Im (atRF = 0 O) < 0.7 mA Permissible extraneous DC voltage Ufg < 1600 V Permissible system leakage capacitance Ce 0...4000 |jF for Un > 500 V no longer in accordance with IEC61557-8 Operating mode Functions High level Low level Rated impulse voltage Rated insulation voltage Safe isolation...

 Open the catalog to page 7
ISOMETER® isoPV1685DP-8

Serial interface Terminals A/B Shield: terminal S Rel. humidity Area of application Cable length Shielded cable (shield to functional earth on one end) Terminating resistor, can be connected (Term. RS-485) Ambient temperature Device address, Modbus RTU Baud rate Stop bits Classification of climatic conditions acc. to IEC 60721: Switching elements Switching elements Insulation fault alarm 1 Insulation fault alarm 2 Classification of mechanical conditions acc. to IEC 60721: Device error Operating mode continuous operation Electrical endurance under rated operating conditions vertical, mains connection...

 Open the catalog to page 8
ISOMETER® isoPV1685DP-9

Ordering details Model Response value Supply voltage

 Open the catalog to page 9
ISOMETER® isoPV1685DP-10

Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until unless otherwise indicated.

 Open the catalog to page 10

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.