1. Catalogs
  2. BENDER GmbH & Co KG
  3. ISOMETER® isoCHA425HV with AGH420-1/AGH421-1

ISOMETER® isoCHA425HV with AGH420-1/AGH421-1
1 /12Pages

ISOMETER® isoCHA425HV with AGH420-1/AGH421-1

ISOMETER® isoCHA425HV with AGH420-1/AGH421-1
1 /12Pages

Catalog excerpts

ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-2

The ISOMETER® isoCHA425HV in combination with the AGH420-1/AGH421-1 coupling device monitors the insulation resistance for DC fast charging stations according to the CHAdeMO standard or according to the Combined Charging System (CCS) for nominal system voltage ranges between DC 0 V and 1000 V. ■ Switchable between CCS (Combined Charging System) and CHAdeMO ■ Detection of symmetrical and asymmetrical insulation faults ■ Electrically isolated Modbus RTU interface ■ Display of the fault location (DC-balanced) ■ Only one device for use in all regions and applications ■ Compact design for optimum...

 Open the catalog to page 2
ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-3

Can be used worldwide thanks to international approvals Optimised and accelerated testing and approval processes for UL-certified charging stations High flexibility and low variant diversity thanks to switching between CHAdeMO and CCS mode ococ OOQO A high level of electrical safety is a priority for DC charging stations. In order to minimise the risk to the user, the ISOMETER® isoCHA425HV fulfils all the important requirements placed on the insulation monitoring device by the standards and regulations.

 Open the catalog to page 3
ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-4

■ Detection of insulation faults up to 2 MQ ■ Maximum allowed system leakage capacitance ■ Active measuring method can detect symmetrical and asymmetrical insulation faults ■ Voltage measurement with overvoltage and undervoltage detection ■ Automatic device self-test with connection monitoring ■ High system reliability ■ High availability of the charging station ■ Ideal for e-bus charging applications etc. thanks to high permissible leakage capacitance

 Open the catalog to page 4
ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-6

Most compact design in the market: Flexible arrangement of insulation monitoring and coupling device Push-In wire connectors ■ Optimum utilisation of the available installation space within the charging station ■ Time savings during production thanks to fast wiring The demand for elegant and compact fast charging stations is on the rise. The ISOMETER8 isoCHA425HV supports this trend with its compact design.

 Open the catalog to page 6
ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-7

“With the isoCHA insulation monitor from Bender, our charging systems are safe and fulfil the current charging standards. With its high, permissible system leakage capacitances, it makes it possible to charge large electric vehicles. ” Dr. Raoul Heyne, ADS-TEC Energy, Senior Expert Chargin

 Open the catalog to page 7
ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-8

▪ RS-485 ▪ Modbus RTU ▪ IsoData ▪ LC display ▪ Password protection against unauthorised parameter changes Benefits: ▪ Q uick and easy integration of the IMD in the charge controller using standard protocols ▪ S imple troubleshooting on site by me

 Open the catalog to page 8
ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-10

In fast charging stations with dynamic load distribution to two charging points, one IMD often has to be disconnected from the grid to avoid interference as long as the maximum power of a charging station is only made available to one vehicle. The new AGH421-1 coupling device in combination with the ISOMETER® isoCHA425HV enables disconnection from the grid without the installation of additional switching units. Benefits: ▪ C ost and space savings within the charging station by eliminating additional switching units ▪ R educed wiring effort during the production

 Open the catalog to page 10
ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-11

Both IMDs are active Link voltage Charging voltage Vehicle battery voltage Variable DC/DC converter Galvanically Isolated Variable DC/DC converter IMD 2 disconnected from the system to be monitored Link voltage Charging voltage Vehicle battery voltage Variable DC/DC converter Galvanically Isolated Variable DC/DC converter The entire available power is used for charging one vehicle. IMD2 must be disconnected to avoid interference

 Open the catalog to page 11
ISOMETER® isoCHA425HV with AGH420-1/AGH421-1-12

Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-707 [email protected] www.bender.de/en Fotos: Adobe Stock (© Southworks, © BornHappy) and Bender Archive. 2248en / 05.2024 / © Bender GmbH & Co. KG, Germany – subject to change! The specified standards take into account the version valid at the time of print

 Open the catalog to page 12

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.