ICC1324

ICC1324

ICC1324

Product catalog summary
Overview: The ICC1324 charge controller is designed for electric vehicle charging systems, compliant with IEC 61851-1 (mode 3 charging). It supports both master and slave configurations, dynamic load management, and integrates various communication protocols including OCPP 1.5 and 1.6.
Product Features:
  • Configurable for master and slave operation, allowing setup with two charging points.
  • Dynamic load management optimizes power distribution among charging points.
  • Includes a patented residual direct current monitoring module, requiring an external RCD type A.
  • Supports integration in single- or three-phase systems up to 3x 32 A.
  • Compliant with OCPP 1.5 and 1.6, supporting JSON and SOAP.
  • Equipped with an integrated 4G modem, WiFi module, and two Ethernet interfaces.
  • Features ISO 15118 Powerline Communication for plug & charge and load management.
Functional Description:
  • Includes an RCD type A and a contactor, connected to type 1 or type 2 socket-outlets.
  • Supports Modbus meter for digital energy consumption reading.
  • Features an RFID module for user interaction and a micro SIM card slot for 4G connectivity.
  • Dynamic Load Management (DLM) software prevents peak and unbalanced loads.
Technical Specifications:
  • Rated voltage: 250 V, Pollution degree: 2, Overvoltage category: II and III.
  • Supply voltage: AC 230 V, Frequency: 50 Hz, Max power consumption: 12 W.
  • Residual direct current monitoring module with a measuring range of 100 mA.
  • WiFi standards: IEEE 802.11b/g/n, Frequency: 2.4 GHz.
  • Operating temperature range: -25 to +65 °C, Degree of protection: IP20.
Ordering Information: Various accessories and plug kits are available, including current transformers and connection cables of different lengths.
Specifications: The document outlines the ICC1324 series, including models such as Connect Plus, Connect, Connect SP, Home Plus, and Home. These models are associated with specific product codes.
Procedures: Powerline Communication is implemented according to ISO/IEC 15118 standards. The charge controller requires a residual direct current monitoring module (RDC-M) to function, which must be used in conjunction with a separately ordered measuring current transformer. Various cable lengths are available for these setups.
Standards and Compliance: The document references standards valid until December 2022, with a note that specifications are subject to change.
Contact Information: Bender GmbH & Co. KG is the manufacturer, located in Grünberg, Germany. Contact details include a phone number and email address for further inquiries.
See more

Catalog excerpts

ICC1324-1

Charge controller for charging systems for electric vehicle charging Image similar

 Open the catalog to page 1
ICC1324-2

ICC1324 charge controller Charge controller for charging systems for electric vehicle charging Product features (depending on the variant) • Charge controller in accordance with IEC 61851-1 (mode 3 charging) • Master and slave operation configurable - Setting up charging ssystems with two charging points: 1 charge controller as data gateway with 4G modem and 1 charge controller as slave without 4G modem • Dynamic load management to optimally distribute the available power among all charging points and signal the maximum power to the vehicle • Patented residual direct current monitoring module...

 Open the catalog to page 2
ICC1324-3

The charging system consists of an RCD type A and a contactor. These are directly connected to a type 1 or type 2 socket-outlet, or to an attached cable with a type 1 or type 2 plug. • The charging system can be equipped with a meter. A Modbus meter is required for digital reading of the energy consumption. The Modbus RTU wires are attached directly to the charge controller. Alternatively, a meter can be connected to an Ethernet interface via Modbus TCP. • An AC 230 V power supply is needed for operation. • An RFID module can be used for easy user interaction. • Power flow toward the vehicle...

 Open the catalog to page 3
ICC1324-4

ICC1324 charge controller Z BENDER Charging system with type 2 socket-outlet A PE, Modbus meter, CP, PP B Connection Ethernet (ETH2) E Micro SIM card slot (only available for variants with 4G modem)1 F LED service G Antenna socket 4G (only available for variants with 4G modem1) H Configuration interface USB type B J Connection measuring current transformer (CT) K Locking, control relay GPIO L Optocoupler input M Weld check, relay for contactor control rated for 230 V/4 A N Power supply AC 230 V "m RCD type A Measuring current transformer (CT) with plug [)| Contactor g| Type 2 socket-outlet 1Data...

 Open the catalog to page 4
ICC1324-5

Technical data III (terminal M and all other terminals) 6 kV (terminal M and all other terminals) 2.5 kV (within terminal M) terminal M and all other terminals within terminal M < 2000 m AMSL Standards Frequency bands Channel band width Data rate Rated voltage / Pollution degree Overvoltage category Overvoltage category Rated impulse voltage Rated impulse voltage Double insulation acc. to OVC III between Basic insulation acc. to OVC II Operating altitude Supply voltage AC 230 V (terminal N (L1, N)) Supply voltage range Us 184 V ... 264 V maximum Power consumption 12 W average Power consumption...

 Open the catalog to page 5
ICC1324-6

ICC1324 charge controller Z BENDER Technical data Cable lengths/cable types Optocoupler 1 (terminal L (Opto 1 In+, Opto 1 In-)) Input voltage (HIGH) Input current Optocoupler 2 (terminal L (Opto 2 In+, Opto 2 In-)) Input voltage (HIGH) Input current Potential difference to PE/GND shielded on one side, shield on charge controller side to PE Weld check (terminal M (WB, WA)) Potential difference to PE/GND max. 100 V* * The potential difference between the optocoupler inputs and other inputs/outputs must be less than 100 V. DC 15 V voltage source (terminal A (15 V, 0 V)) maximum load capacity 0,4...

 Open the catalog to page 6
ICC1324-7

Ordering information 21 The PCB-variant can be combined with the connection cables of different lengths

 Open the catalog to page 7
ICC1324-8

BENDER Group ICC1324_D00436_01_D_XXEN/12.2022 / © Bender GmbH & Co. KG, Deutschland – Subject to change! The specified standards take into account the edition valid until 12.2022 unless otherwise indicated. Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • [email protected] • www

 Open the catalog to page 8

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1314

    8  Pages

  18. AGH676S-4

    4  Pages

  19. AGH520S

    4  Pages

  20. AGH204S-4

    4  Pages

  21. AGH150xx

    4  Pages

  22. AT series

    6  Pages

  23. DI-1DL

    4  Pages

  24. SMO482P-12

    4  Pages

  25. DI-2USB

    4  Pages

  26. POWERSCOUT®

    8  Pages

  27. SEB30, SEB60

    8  Pages

  28. VIT-AFSBY

    6  Pages

  29. VIT-A

    6  Pages

  30. RDC125-5S

    12  Pages

  31. RCMB131-01

    4  Pages

  32. RDC121

    7  Pages

  33. RCMB123

    7  Pages

  34. RDC104-4

    6  Pages

  35. RCMB104

    6  Pages

  36. RCMB300-series

    12  Pages

  37. Energy meter

    6  Pages

  38. PEM353

    8  Pages

  39. DS0107

    6  Pages

  40. ESL0107

    4  Pages

  41. ES710

    8  Pages

  42. AGH520S

    4  Pages

  43. RCM410R

    8  Pages

  44. RCMS410

    10  Pages

  45. RCMS425-D

    10  Pages

  46. EDGE500

    12  Pages

  47. Iso415R

    4  Pages

  48. Iso685-x-B

    12  Pages

  49. Iso685-x-P

    14  Pages

  50. Iso685-x

    12  Pages

  51. Data Centers

    16  Pages

  52. RCMB104

    6  Pages

  53. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.