CTBC17 series
1 /8Pages

CTBC17 series

CTBC17 series
1 /8Pages

Catalog excerpts

CTBC17 series-1

CTBC17 series AC/DC sensitive measuring current transformers

 Open the catalog to page 1
CTBC17 series-2

AC/DC sensitive measuring current transformers (conformity for cable variant only) Device features • Suitable for AC/DC sensitive residual current measurement according to IEC 62752 and IEC 60755 • Suitable for DC fault current monitoring to protect type A RCDs in conjunction with the listed evaluators • Shield to prevent interferences caused by high load currents and external magnetic fields • Connection cable for direct mounting available (depends on variant) • Can be used in applications according to Product description The AC/DC sensitive measuring current transformers can be used in all...

 Open the catalog to page 2
CTBC17 series-3

Measuring current transformers CTBC17 series Technical data Insulation coordination according to IEC 60664-1 CT cable feed-through opening on primary side (IC1) Measuring circuit; CT on secondary side (IC2) Connection cable measuring circuit (IC3) Operating altitude Basic insulation < 4000 m AMSL Double insulation < 2000 m AMSL Rated impulse voltage Rated insulation voltage Safe separation (double insulation) between Insulation coordination according to IEC 62955 Pin length from top edge of PCB Connection windings Pin length from top edge of PCB Enclosure retaining pin pull-out forces Soldering...

 Open the catalog to page 3
CTBC17 series-4

Measuring current transformers CTBC17 series Z BENDER Connection cable plug Pin assignment plug application side Pin no

 Open the catalog to page 4
CTBC17 series-5

Measuring current transformers CTBC17 series Observe bending radius of the connection cable: – Once = 8x Da* – Several times = 15x Da* * Da = external diameter Dimension diagram – PCB variant Dimensions in mm General tolerance acc. to ISO 2768-1 m 21,3 ±0,5 Länge Kontaktstifte/Contact pins 3,9 ±0,3 Länge Lötpinfixierung/Fixing pins Dimensions in mm General tolerance acc. to ISO 2768-1 f Drilling diagram PCB mounting 4 x ø1 2 x Ø 2,70 Optionale Fixierung/ Optional fixation 2 x Würth WüPlast 2,5x8

 Open the catalog to page 5
CTBC17 series-6

Measuring current transformers CTBC17 series Pin assignment sensor pin side CTBC17P-03 Measurement winding Measurement winding Test winding n. c. Measurement winding Test winding Connection example Cable variant – CTBC17 with CC613 charge controller Connection example PCB variant – CTBC17 with RCMB104 evaluator working voltage to driver circuit, control electronics or µC Residual current sensor Laderegler Charge controller

 Open the catalog to page 6
CTBC17 series-7

Measuring current transformers CTBC17 series Installation instructions measuring CTs The measuring current transformer must be connected to the evaluator before commissioning the system. Output connections shall be powered by Class 2 or Limited Voltage / Limited Current circuits.! 1 Primary conductor All current-carrying cables must be routed through the measuring current transformer. Do not route any shielded cables through the measuring current transformer! PE Never route an existing protective conductor through the measuring current transformer. The primary conductors may only be bent from...

 Open the catalog to page 7
CTBC17 series-8

eMobility E-Mail: [email protected] www.bender.de/loesungen/emobility BENDER Group CTBC17_D00421_01_D_XXEN/05.2023 / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the edition valid until 05.2023 unless otherwise indicated. Bender GmbH & Co. KG Londorfer Straße 65 • 35305 Grünberg • Germany Tel.: +49 6401 807-0 • [email protected] • www

 Open the catalog to page 8

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. IPM1300

    8  Pages

  15. CC613

    6  Pages

  16. ICC1324

    8  Pages

  17. ICC1314

    8  Pages

  18. AGH676S-4

    4  Pages

  19. AGH520S

    4  Pages

  20. AGH204S-4

    4  Pages

  21. AGH150xx

    4  Pages

  22. AT series

    6  Pages

  23. DI-1DL

    4  Pages

  24. SMO482P-12

    4  Pages

  25. DI-2USB

    4  Pages

  26. POWERSCOUT®

    8  Pages

  27. SEB30, SEB60

    8  Pages

  28. VIT-AFSBY

    6  Pages

  29. VIT-A

    6  Pages

  30. RDC125-5S

    12  Pages

  31. RCMB131-01

    4  Pages

  32. RDC121

    7  Pages

  33. RCMB123

    7  Pages

  34. RDC104-4

    6  Pages

  35. RCMB104

    6  Pages

  36. RCMB300-series

    12  Pages

  37. Energy meter

    6  Pages

  38. PEM353

    8  Pages

  39. DS0107

    6  Pages

  40. ESL0107

    4  Pages

  41. ES710

    8  Pages

  42. AGH520S

    4  Pages

  43. RCM410R

    8  Pages

  44. RCMS410

    10  Pages

  45. RCMS425-D

    10  Pages

  46. EDGE500

    12  Pages

  47. Iso415R

    4  Pages

  48. Iso685-x-B

    12  Pages

  49. Iso685-x-P

    14  Pages

  50. Iso685-x

    12  Pages

  51. Data Centers

    16  Pages

  52. RCMB104

    6  Pages

  53. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.