COMTRAXX® MK2430-1

Remote alarm indicator and test combination with LC display

 Open the catalog to page 1
COMTRAXX® MK2430-2

Device features • Display of operating status, warning and alarm messages in accordance with DIN VDE 0100-710, IEC 60364-7-710 and other standards • Backlit clear LC text display (4 x 20 characters) • Predefined standard texts in 20 languages • 200 freely programmable message texts • Bus technology for easy installation and reduced fire load • Audible alarm (can be acknowledged) • Parameter setting via menu (German/English) • Suitable for flush and surface mounting • Easy commissioning due to predefined message texts • 12 digital inputs/1 relay output (MK2430-11 only) • History memory with real-time...

 Open the catalog to page 2
COMTRAXX® MK2430-3

Standard message texts can be activated by enabling alarm addresses. These texts are available in 20 languages. Standard message texts can be activated by enabling alarm addresses . Individual message texts each comprising 6 lines of 20 characters can be programmed with the TMK-SET software. An LED (yellow or red) and an audible signal can be assigned to each message. For this purpose, the PC is connected to the USB interface or BMS bus (RS-485) via converter. History memory Warning and alarm messages are written to the history memory automatically with date and time stamp. 250 text messages...

 Open the catalog to page 3
COMTRAXX® MK2430-4

3 - Power supply unit incorporated in the MEDICS® module, sufficient for supplying power to maximum three MK2430 4 - Cable between MEDICS® module and MK2430 When the MK2430 is supplied by the AN410 or AN450 power supply unit in the MEDICS® modules, the permissible cable lengths and cable cross sections have to be considered. The digital inputs may be controlled either via potential-free contacts or via voltage signals. If you are using potential-free contacts, the voltage can be drawn from the AN410 or AN450 (3). When the inputs are activated via an external voltage, the common 0(-) is connected...

 Open the catalog to page 4
COMTRAXX® MK2430-5

Technical data Rated insulation voltage Rated impulse withstand voltage/pollution degree Supply voltage Supply voltage Us Frequency range US Operating range Us Power consumption Voltage failure without reset Max. cable length in case of power supply of 1/2/3 MK24_ from one AN410 Front foil RAL 7035 (light grey); RAL 7040 (basalt grey) Marking RAL 5005 (ultramarine blue) Front plate RAL 7035 (light grey) Display, characters four lines, 4 x 20 characters Standard message texts in Alarm addresses configurable Programmable text messages History memory (messages) Standard text message Additional text...

 Open the catalog to page 5
COMTRAXX® MK2430-6

Dimension diagram flush-mounting type Dimension diagram surface-mounting type Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 07.2023 unless otherwise indicated.

 Open the catalog to page 6

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.