Device Features
The COMTRAXX® CP9…-I Series Condition Monitor features display sizes of 7" and 15.6" with tempered, anti-reflective glass. It is easy to clean, disinfect, and has an IP54 protection rating. The device includes a screwless mounted front plate and serves as a condition monitor for Bender systems with an integrated modular gateway for TCP/IP connectivity. It supports remote access via LAN, WAN, or Internet and can interface with devices connected to the internal BMS bus, BCOM, Modbus RTU, or Modbus TCP. The monitor offers silent operation, high-quality display, and customizable visualizations.

Intended Use
The CP9…-I monitors alarms, measured values, and states of devices such as Bender devices with BMS bus or BCOM interface, and other devices with Modbus RTU or Modbus TCP interface. Data is accessible via Modbus TCP, Modbus RTU, SNMP, MQTT, and PROFINET protocols, allowing integration with building control systems and visualization through web browsers.

Applications
The device is used for monitoring and parameter setting of Bender products, remote diagnosis, control stations, and data center monitoring. It provides notifications in case of errors.

Scope of Functions
The CP9…-I offers a web interface and display, supports integration of up to 150 devices via BMS bus, 255 via BCOM, and 247 each via Modbus RTU and TCP. It includes features like system overview, configurable visualization, Ethernet interface for remote access, time synchronization, history memory, data logger, email notifications, and device documentation. It supports control commands via Modbus and access to alarms and measured values via SNMP and MQTT.

Interfaces
The device communicates via internal BMS bus, BCOM, Modbus RTU, and Modbus TCP. It can operate as a master or slave on the BMS bus and supports Ethernet connections for BCOM and Modbus TCP.

Technical Data
The CP907-I operates at a rated voltage of 50 V, while the CP915-I operates at AC 250 V. Both models have specific power consumption and cable length specifications. The device supports various interfaces including Ethernet, BMS-Bus, BCOM, Modbus, PROFINET, SNMP, MQTT, and USB.

Environmental and Mechanical Conditions
The device is designed for continuous operation with specific operating temperature ranges and humidity levels. It meets various IEC standards for EMC and mechanical conditions.

Ordering Information
The document provides details on ordering complete devices and individual components, including display sizes, supply requirements, and enclosure types.
See more

Catalog excerpts

COMTRAXX® CP9…-I Series-1

COMTRAXX® CP9…-I Series Condition Monitor with display and integrated gateway

 Open the catalog to page 1
COMTRAXX® CP9…-I Series-2

I Series Condition Monitor with display and integrated gateway Device features • Display sizes 7" and 15.6" with tempered and anti-reflective glass • Easy to clean and disinfect, degree of protection IP54 • Screwless mounted front plate • Condition monitor for Bender systems • Integrated modular gateway between Bender systems and TCP/IP • Remote access via LAN, WAN or Internet • Support of devices that are connected to the internal BMS bus, via BCOM, Modbus RTU or Modbus TCP • Individual visualisation can be generated, which can be viewed via the web browser or on the display • Silent due to...

 Open the catalog to page 2
COMTRAXX® CP9…-I Series-3

Scope of functions CP9...-I (V4.9.0 and higher) • Condition monitor with web interface and display • Interfaces for the integration of devices - Modbus RTU and Modbus TCP (max. 247 devices each) • Selectable display content - System overview with all devices, measured values, parameters and alarms - Individually configurable visualisation • Ethernet interface with 10/100 Mbit/s for remote access via LAN, WAN or Internet • Time synchronisation for all assigned devices • History memory (20,000 entries) • Data logger, freely configurable (30 x 10,000 entries) • Assignment of individual texts for...

 Open the catalog to page 3
COMTRAXX® CP9…-I Series-4

Interfaces CP9xx-I communicate with the devices and systems assigned via various interfaces: • Internal BMS bus (RS-485) for Bender systems such as EDS46…/49…, RCMS46…/49… and MEDICS®. CP9…-I can be operated as a master or as a slave. When operated as a master, requests are answered more quickly. The devices can only be operated on the internal BMS bus. System overview interfaces CP9…-I • BCOM (Ethernet) for new and future Bender systems, such as ISOMETER® iso685-D. • Modbus RTU (RS-485) for Bender devices such as RCMS410. • Modbus TCP (Ethernet) fo

 Open the catalog to page 4
COMTRAXX® CP9…-I Series-5

Technical data Rated impulse voltage 800 V Overvoltage category for UL applications II Rated impulse voltage 4 kV Displays, memory E-mail configuration and device failure monitoring Max. 250 entries Individual texts Unlimited number of texts with 100 characters each Number of data points for "third-party devices" to 1600 Number of data loggers 30 Number of data points per data logger 10,000 Number of entries in the history memory 20,000 Background image size max. 3 MB Nominal voltage Nominal voltage tolerance Typical power consumption at DC 24 V Maximum cable length when supplied via B95061210...

 Open the catalog to page 5
COMTRAXX® CP9…-I Series-6

COMTRAXX® CP9...-I Series Efc BENDER Interface/protocol Cable length BCOM system name BCOM subsystem address BCOM device address Modbus Bender Modbus image V1, V2 (V2)* DNS (UDP/TCP) DHCP (UDP) HTTP (TCP) NTP (UDP) SNMP (UDP) SNMP TRAPS (UDP) HTTPS (TCP) MODBUS (TCP) OPCUA (TCP) MDNS (UDP) BCOM (UDP) Cable length Operating mode Client for Bender Modbus TCP devices and "third-party devices" Operating mode Server for access to process image and for Modbus control commands Parallel data access from different clients Digital inputs (1.12) Number Galvanic separation Maximum cable length Operating...

 Open the catalog to page 6
COMTRAXX® CP9…-I Series-7

Device connections Classification of climatic conditions acc. to IEC 60721 Terminal block (L1; N; PE) (for CP915-I only) flexible with ferrule with/without plastic sleeve 0.5.4 mm2 Multiple conductor, flexible with TWIN ferrule with 0.5.4 mm2 plastic sleeve flexible with ferrule with/without plastic sleeve 0.25.2.5 mm2 Multiple conductor, flexible with TWIN ferrule with 0.5.1.5 mm2 plastic sleeve Conductor sizes Stripping length rigid/flexible flexible with ferrule without plastic sleeve flexible with ferrule with plastic sleeve Classification of mechanical conditions acc. to IEC 60721 Operating...

 Open the catalog to page 7
COMTRAXX® CP9…-I Series-8

COMTRAXX® CP9...-I Series Efc BENDER Complete devices 1) The suction lifter is required to remove the display of the CP915-I.

 Open the catalog to page 8
COMTRAXX® CP9…-I Series-9

Dimension diagram Device dimensions Installation dimensions enclosure Flush-mounting Door Surface-mounting Flush-mounting Surface-mounting Required installation depth

 Open the catalog to page 9
COMTRAXX® CP9…-I Series-10

Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 09.2025 unless otherwise indicated.

 Open the catalog to page 10

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.