COMTRAXX® CP305

COMTRAXX® CP305
1 / 12 PagesView full catalog

COMTRAXX® CP305

Product catalog summary
Overview: The COMTRAXX® CP305 is a control panel designed for remote alarm indication in critical environments such as medical facilities. It provides both visual and acoustic signals for operational and alarm messages from Bender systems like MEDICS®, ATICS®, EDS, and RCMS.
Standards and Approvals: The CP305 complies with DIN VDE 0100-710 and is UL certified, ensuring adherence to international safety and performance standards.
Intended Use: This device is used for monitoring and signaling in healthcare, industrial, office, and public buildings, playing a crucial role in IT system monitoring and messaging from changeover devices.
Key Features:
  • Displays various conditions such as normal operation, insulation faults, overloads, and overtemperature.
  • Includes 12 digital inputs and 2 relay contacts for system integration.
  • Features configurable LED alarm colors and acoustic signals.
  • Equipped with a 5" touch display offering high resolution and a wide viewing angle.
  • Rated IP54 for the device and IP66 for the front glass panel.
  • Supports multiple languages and programmable message texts.
Device Features: The CP305 can act as a master in systems with multiple IT and EDS systems, supports bus technology for easy installation, and can be configured via an Ethernet interface.
System Description: Part of the MEDICS® system, the CP305 ensures safe power supply in medical locations and supports BMS and Modbus RTU connections for remote monitoring and maintenance.
Technical Data:
  • Rated voltage: 50 V, with overvoltage category II and pollution degree 2.
  • Power supply: AC/DC 24 V with typical power consumption of less than 4.2 W.
  • Display: 5" TFT touch display with a resolution of 720 x 1280 px.
  • Interfaces: Ethernet and RS-485 for communication and configuration.
  • Environmental conditions: Operating temperature range of -10 to +55 °C, with relative humidity up to 98% at 25 °C.
Installation and Mounting: The CP305 can be flush-mounted, surface-mounted, or installed in cavity walls, requiring specific mounting kits for different installation types.
Ordering Information: Various device variants and accessories are available, including options for customized parameter settings and installation kits.
See more

Catalog excerpts

COMTRAXX® CP305-1

Remote alarm indicator for medical locations and other areas

 Open the catalog to page 1
COMTRAXX® CP305-2

COMTRAXX® CP305 - Control Panel The current overview of Bender devices with radio approval can be found in the Country list of RF Approval. Kr BENDERRemote alarm indicator for medical locations and other areasIntended use The COMTRAXX® CP305 control panel is for visual and acoustic signalling of operating and alarm messages from the Bender systems MEDICS®, ATICS®, EDS and RCMS. In MEDICS® monitoring systems, the CP305 fulfils the requirements of the standard DIN VDE 0100-710 concerning test functions for IT system monitoring and messaging from changeover devices. Testing of the IT system monitoring...

 Open the catalog to page 2
COMTRAXX® CP305-3

COMTRAXX® CP305 - Control Panel Device features The CP305 display shows the messages from all RS-485 bus participants that have been allocated to it via alarm addresses. This means that a CP305 can be used not only as an individual display, but several CP305s can also be employed as parallel displays in different rooms. The alarm colours for the LEDs are configurable (e.g. red for an alarm, yellow for a warning, such as an insulation fault or the like). In addition to the LED, there is also an alarm pop-up (display) as well as an entry in the alarm overview (web user interface) when a message...

 Open the catalog to page 3
COMTRAXX® CP305-4

COMTRAXX® CP305 - Control Panel System description Certification The CP305 remote alarm indicators are components of the MEDICS® systems. MEDICS® is an intelligent system that guarantees safe power supply in medical locations. In the example, the ICU is monitored from the station base via BMS bus. Connection example BMS and Ethernet In the example, the ICU can be monitored from the station base. In addition, remote maintenance is possible via the building services or Bender. For safe operation of the Medics® system in accordance with IEC 60364-7-710 and IEC 61557-8, we recommend operating the...

 Open the catalog to page 4
COMTRAXX® CP305-5

COMTRAXX® CP305 - Control Panel Connection example for Modbus RTU and Ethernet In the example, remote maintenance via the building services or by Bender is possible.

 Open the catalog to page 5
COMTRAXX® CP305-6

COMTRAXX® CP305 - Control Panel Kr BENDER Connection diagram

 Open the catalog to page 6
COMTRAXX® CP305-7

COMTRAXX® CP305 - Control Panel Legend for the connection diagram ** Devices without BMS bus connection, but with test input (e.g ISOMETER®)

 Open the catalog to page 7
COMTRAXX® CP305-8

COMTRAXX® CP305 - Control Panel Kr BENDER Technical Data Overvoltage category II and pollution degree 2 is related to the relay contacts. Further insulation coordination takes place after functional separation. Supply via plug-in terminal (A1/+, A2/-) Rated voltage Operating range of the supply voltage Nominal frequency Typical power consumption Maximum cable length with supply via B95061210 (24 V DC power supply unit 1.75 A) Operating mode Baud rate Cable length Shielded cable, one end of shield Galvanic separation Terminating resistor Device address Number of supported devices Master/slave...

 Open the catalog to page 8
COMTRAXX® CP305-9

COMTRAXX® CP305 - Control Panel Environment/EMC Switching elements Number of changeover contacts Operating principle (changeover contacts) Function Minimum contact load Electrical endurance under rated operating conditions N/C operation / N/O operation Programmable 100 mA/DC 5 V (0.5 W) Rated operational voltage AC 24 V / AC 24 V / DC 24 V Rated operational current AC 2 A / AC 2 A / DC 2 A Buzzer alarm Can be acknowledged, adoption of characteristics of Buzzer interval Configurable Buzzer frequency Configurable Buzzer repetition Configurable Device connections Flexible with ferrules, with/without...

 Open the catalog to page 9
COMTRAXX® CP305-10

COMTRAXX® CP305 - Control Panel Surface mounting Surface mounting requires use of the appropriate surfacemounting enclosure (part. no. B95100153). Any clearance between the surface-mounting enclosure and the wall must be compensated using washers. Never tighten the screws with a cordless screwdriver; only do so by hand. If this is disregarded, the surface-mounted housing can become warped. Dimension diagram flush-mounting enclosure Cavity wall and panel mounting Cavity wall mounting Panel mounting

 Open the catalog to page 10
COMTRAXX® CP305-11

COMTRAXX® CP305 - Control Panel Ordering information Device variants

 Open the catalog to page 11
COMTRAXX® CP305-12

Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 08.2025 unless otherwise indicated.

 Open the catalog to page 12

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.