1. Catalogs
  2. BENDER GmbH & Co KG
  3. COMTRAXX® COM465IP/COM465DP

COMTRAXX® COM465IP/COM465DP

COMTRAXX® COM465IP/COM465DP
1 / 10 PagesView full catalog

COMTRAXX® COM465IP/COM465DP

Product catalog summary
Overview: The COMTRAXX® COM465IP/COM465DP is a condition monitor with an integrated gateway designed to connect Bender devices to PROFIBUS DP and Ethernet-TCP/IP networks. It facilitates remote access and data visualization through web browsers and supports various communication protocols.
Device Features:
  • Condition monitoring for Bender systems with modular gateway capabilities.
  • Supports BMS bus, BCOM, Modbus RTU, and Modbus TCP interfaces.
  • Customizable visualization via web browser.
  • COM465DP includes a gateway for PROFIBUS DP.
Intended Use: The COM465IP and COM465DP connect Bender devices to Ethernet TCP/IP and PROFIBUS DP networks, converting alarms and data into Modbus TCP, SNMP, and HTTP protocols for network integration and web-based evaluation.
Applications:
  • Web-based visualization of device and plant statuses.
  • Monitoring and analysis of Bender and third-party devices.
  • Custom plant overviews and selective alarm notifications.
  • Remote diagnosis and maintenance capabilities.
Scope of Functions:
  • Basic device includes a web interface and multiple integration interfaces.
  • Remote display and parameter setting capabilities.
  • History memory and data logger functionalities.
  • Integration of third-party devices and creation of virtual devices.
Function Modules:
  • Module A: Custom texts, device failure monitoring, and email notifications.
  • Module B: Data provision via Modbus, SNMP, and MQTT.
  • Module C: Parameter setting and device backups.
  • Module D: System visualization with an integrated editor.
  • Module E: Creation of virtual devices.
  • Module F: Integration of third-party devices.
Technical Data:
  • Rated voltage: AC 250 V, with a supply voltage range of AC/DC 24…240 V.
  • Operating temperature: -25 to +55 °C.
  • Interfaces include Ethernet, Modbus, PROFINET, SNMP, MQTT, and PROFIBUS DP.
  • Memory and data logging capabilities with extensive data point integration.
Standards and Certifications: Certified by the PROFIBUS Nutzerorganisation e.V. (PNO) with conformity to PROFIBUS standards.
Ordering Information: Available models include COM465DP-230V and COM465IP-230V, with various function modules available for additional capabilities.
See more

Catalog excerpts

COMTRAXX® COM465IP/COM465DP-1

COMTRAXX® COM465IP/COM465DP Condition Monitor with integrated Gateway for the connection of Bender devices to PROFIBUS DP and Ethernet-TCP/IP networks

 Open the catalog to page 1
COMTRAXX® COM465IP/COM465DP-2

COMTRAXX® COM465IP/COM465DP Condition Momtor wM tategrated Gateway for the connection of Bender devices to PROFIBUS DP and Ethernet-TCP/IP networks Data transfer interfaces SNMP 28MQTT Device features • Condition monitor for Bender systems • Integrated modular gateway between Bender systems and TCP/IP enables remote access via LAN, WAN or Internet • Range of functions adjustable through function modules • Support of devices that are connected to the internal or external BMS bus, via BCOM, via Modbus RTU or Modbus TCP • Individual visualisation can be generated, which is displayed via the web...

 Open the catalog to page 2
COMTRAXX® COM465IP/COM465DP-3

Basic device (without function modules) • Condition monitor with web interface • Interfaces for the integration of devices - Internal BMS bus (max. 150 devices) and external11 BMS bus (max. 99 x 150 devices) - Modbus RTU and Modbus TCP (max. 247 devices each) • Remote display of the latest measured values, status/alarm messages and parameters11 • Gateway to Modbus TCP: Reading the latest measured values, status/alarm messages from addresses 1...10 of the respective interface via Modbus TCP • Gateway to Modbus RTU: Reading the latest measured values, status/alarm messages from addresses 1.10 of...

 Open the catalog to page 3
COMTRAXX® COM465IP/COM465DP-4

100 virtual devices with 16 channels each can be created. 1600 data points from third-party devices (via Modbus RTU or Modbus TCP) can be integrated into the system. For UL applications, the following must be observed: • Maximum ambient temperature: 55 °C • Use 60/70°C copper lines only

 Open the catalog to page 4
COMTRAXX® COM465IP/COM465DP-5

Wiring diagram Wiring diagram COM465…P (example) PROFIBUS DP for COM465DP only

 Open the catalog to page 5
COMTRAXX® COM465IP/COM465DP-6

Technical data ( )* = Factory setting Insulation coordination in acc. with IEC 60664-1/IEC 60664-3 Rated impulse withstand voltage/overvoltage category 4 kV / III Protective separation (reinforced (A1/+, A2/-) - [(AMB, BMB), (ABMS, insulation) between BBMS), (X2), (X3, X4), (PROFIBUS DP)] Supply voltage Supply voltage Us Frequency range Us Power consumption Connection Cable length Data rate HTTP mode DHCP nnn.nnn.nnn.nnn can always be reached via Netmask Protocols (depending on function module selected) 10/100 MBit/s, autodetect HTTP/HTTPS (HTTP)* on/off (on)* 5.60 s (30 s)* (192.168.0.254)*...

 Open the catalog to page 6
COMTRAXX® COM465IP/COM465DP-7

Classification of climatic conditions acc. to IEC 60721 Operating mode master/slave (master)* Baud rate Cable length shielded, one end of shield connected to PE Connection type see connection "Push-wire terminal X1" Terminating resistor Supported Modbus RTU slave addresses Connection type pluggable push-wire terminals Supported devices Trap support Interface/protocol Ethernet/PROFINET Operating mode slave (IO device) queries to all devices (channels) possible Push-wire terminals flexible with ferrule with/without plastic sleeve 0.25.2.5 mm2 Multiple conductor, flexible with TWIN 0.5.1.5 mm2 ferrule...

 Open the catalog to page 7
COMTRAXX® COM465IP/COM465DP-8

Certification by the PROFIBUS Nutzerorganisation e.V. (PNO) is available. PROFIBUS conformity: Z02007 Dimensions Dimension diagram (in mm) Ordering information Device

 Open the catalog to page 8
COMTRAXX® COM465IP/COM465DP-9

Application example

 Open the catalog to page 9
COMTRAXX® COM465IP/COM465DP-10

Bender GmbH & Co. KG Londorfer Straße 65 35305 Grünberg Germany Tel.: +49 6401 807-0 [email protected] www.bender.de © Bender GmbH & Co. KG, Germany Subject to change! The specified standards take into account the edition valid until 09.2025 unless otherwise indicated.

 Open the catalog to page 10

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD25000

    4  Pages

  2. CD14400

    4  Pages

  3. CD1000

    4  Pages

  4. AUR381Z

    4  Pages

  5. AN110

    4  Pages

  6. AGH575S-6

    4  Pages

  7. CD1000-2

    4  Pages

  8. MRCDB300 series

    12  Pages

  9. AN111

    4  Pages

  10. AN450

    4  Pages

  11. AN420

    4  Pages

  12. AN410

    4  Pages

  13. STEP-PS

    8  Pages

  14. CTBC17 series

    8  Pages

  15. IPM1300

    8  Pages

  16. CC613

    6  Pages

  17. ICC1324

    8  Pages

  18. ICC1314

    8  Pages

  19. AGH676S-4

    4  Pages

  20. AGH520S

    4  Pages

  21. AGH204S-4

    4  Pages

  22. AGH150xx

    4  Pages

  23. AT series

    6  Pages

  24. DI-1DL

    4  Pages

  25. SMO482P-12

    4  Pages

  26. DI-2USB

    4  Pages

  27. POWERSCOUT®

    8  Pages

  28. SEB30, SEB60

    8  Pages

  29. VIT-AFSBY

    6  Pages

  30. VIT-A

    6  Pages

  31. RDC125-5S

    12  Pages

  32. RCMB131-01

    4  Pages

  33. RDC121

    7  Pages

  34. RCMB123

    7  Pages

  35. RDC104-4

    6  Pages

  36. RCMB104

    6  Pages

  37. RCMB300-series

    12  Pages

  38. Energy meter

    6  Pages

  39. PEM353

    8  Pages

  40. DS0107

    6  Pages

  41. ESL0107

    4  Pages

  42. ES710

    8  Pages

  43. AGH520S

    4  Pages

  44. RCM410R

    8  Pages

  45. RCMS410

    10  Pages

  46. RCMS425-D

    10  Pages

  47. EDGE500

    12  Pages

  48. Iso415R

    4  Pages

  49. Iso685-x-B

    12  Pages

  50. Iso685-x-P

    14  Pages

  51. Iso685-x

    12  Pages

  52. Data Centers

    16  Pages

  53. RCMB104

    6  Pages

  54. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.