CD25000

CD25000

CD25000

Product catalog summary
Product Description: The CD25000 coupling device is designed for use with an NGR monitor in High Resistance Grounding (HRG) systems with a system voltage up to 25 kV (14.5 kV for NGR). It is suitable for applications at altitudes up to 5000 meters above sea level.
Application: The device is applicable for HRG systems up to AC 25 kV and/or DC 14.5 kV.
Function: When combined with an NGR monitor, the CD25000 extends the application range of the neutral grounding resistor monitor to a system voltage of 25 kV. The duty time is limited to 10 seconds, with a cool-down period of 120 minutes.
Ordering Details: The CD25000 is available with an article number B98039055, supporting voltages up to 25000 V and 14500 V for NGR.
Device Features: The device supports system voltages up to AC 25 kV/DC 14.5 kV and is certified for use up to 5000 meters.
Wiring Diagrams: The internal wiring diagram specifies connections for terminals N, RS, E, and PE, with specific cable sizes and connection instructions.
Insulation Coordination: The device adheres to DIN EN 50178:1997 standards, with rated voltage at 14500 V and overvoltage category III.
Technical Data: The device operates without ground fault indefinitely at 2800 V and with ground fault for 10 seconds at 14500 V. It has an overload capacity of 1.15 times the rated voltage for less than 10 seconds. The resistance is 100 kΩ ±0.5%, with a temperature coefficient of 20 ppm/K.
Environmental Conditions: The device operates in temperatures from -40 to +70 °C, with a humidity tolerance of up to 98%. It is classified under various IEC 60721 standards for climatic and mechanical conditions.
Connection Details: The device supports various conductor sizes and types, with specified tightening torques for connections.
Other Specifications: The device can be mounted in any position, with a maximum operating altitude of 5000 meters. It has an IP54 protection rating and a flammability class of UL 94V-0. The device weighs less than 11 kg.
See more

Catalog excerpts

CD25000-1

E& BENDER The Power in Electrical Safety6

 Open the catalog to page 1
CD25000-2

Coupling device CD25000 Product description The CD25000 can be used with an NGR monitor in HRG systems with a system voltage up to Ull = 25 kV (Ungr = 14.5 kV). The maximum operating altitude is 5000 m above mean sea level. • The coupling device is suitable for HRG applications up to AC 25 kV and/or DC 14.5 kV. The combination of an NGRM... and a coupling device extends the range of application of the neutral grounding resistor monitor up to a system voltage of 25 kV. The duty time is limited to 10 s (minute), the cool-down period is 120 minutes. Ordering details Device features • Coupling device...

 Open the catalog to page 2
CD25000-3

Internal wiring diagram CD25000 Wiring diagrams Wiring diagram i The „N“ terminal of the CD25000 should be connected directly to the star point of the transformer, so that the connection between NGR and star point is also monitored. A direct connection between the „N“ connections of the CD25000 and the NGR is not recommended, as in this case a line interruption between the star point and the NGR connection „N“ would not be monitored.

 Open the catalog to page 3
CD25000-4

Technical data Rated insulation voltage no galvanic separation between the circuits! Voltage range Operating time without ground fault (2800 V) with ground fault (14500 V) Cool-down period Overload capacity unlimited 10 seconds 120 minutes 1.15 x Un for < 10 seconds Classification of mechanical conditions acc. to IEC 60721 Connection RS and E Tightening torque Conductor sizes Stripping length Conductor, rigid Conductor, flexible Multiple conductor, flexible with ferrule without plastic sleeve with ferrule with plastic sleeve Multiple conductor, flexible with TWIN ferrule with plastic sleeve Connection...

 Open the catalog to page 4

All BENDER GmbH & Co KG catalogs and technical brochures

  1. CD14400

    4  Pages

  2. CD1000

    4  Pages

  3. AUR381Z

    4  Pages

  4. AN110

    4  Pages

  5. AGH575S-6

    4  Pages

  6. CD1000-2

    4  Pages

  7. MRCDB300 series

    12  Pages

  8. AN111

    4  Pages

  9. AN450

    4  Pages

  10. AN420

    4  Pages

  11. AN410

    4  Pages

  12. STEP-PS

    8  Pages

  13. CTBC17 series

    8  Pages

  14. IPM1300

    8  Pages

  15. CC613

    6  Pages

  16. ICC1324

    8  Pages

  17. ICC1314

    8  Pages

  18. AGH676S-4

    4  Pages

  19. AGH520S

    4  Pages

  20. AGH204S-4

    4  Pages

  21. AGH150xx

    4  Pages

  22. AT series

    6  Pages

  23. DI-1DL

    4  Pages

  24. SMO482P-12

    4  Pages

  25. DI-2USB

    4  Pages

  26. POWERSCOUT®

    8  Pages

  27. SEB30, SEB60

    8  Pages

  28. VIT-AFSBY

    6  Pages

  29. VIT-A

    6  Pages

  30. RDC125-5S

    12  Pages

  31. RCMB131-01

    4  Pages

  32. RDC121

    7  Pages

  33. RCMB123

    7  Pages

  34. RDC104-4

    6  Pages

  35. RCMB104

    6  Pages

  36. RCMB300-series

    12  Pages

  37. Energy meter

    6  Pages

  38. PEM353

    8  Pages

  39. DS0107

    6  Pages

  40. ESL0107

    4  Pages

  41. ES710

    8  Pages

  42. AGH520S

    4  Pages

  43. RCM410R

    8  Pages

  44. RCMS410

    10  Pages

  45. RCMS425-D

    10  Pages

  46. EDGE500

    12  Pages

  47. Iso415R

    4  Pages

  48. Iso685-x-B

    12  Pages

  49. Iso685-x-P

    14  Pages

  50. Iso685-x

    12  Pages

  51. Data Centers

    16  Pages

  52. RCMB104

    6  Pages

  53. Main Catalogue

    486  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.